Download DP-F30 Series/FC-20 : Two Stage Batch Controller/Ratemeter, FC

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Signal-flow graph wikipedia , lookup

Ohm's law wikipedia , lookup

Power inverter wikipedia , lookup

Rectifier wikipedia , lookup

Audio power wikipedia , lookup

Electrification wikipedia , lookup

Control system wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Flip-flop (electronics) wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Buck converter wikipedia , lookup

Analog-to-digital converter wikipedia , lookup

Power electronics wikipedia , lookup

Schmitt trigger wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
TWO STAGE BATCH CONTROLLER/RATEMETER
with Optional RS232/422 Computer Interface Capability
NEMA4x/IP65 Front
Panel Cover
Displays Rate, Batch
Total and Grand Total
Accepts Pulse or Linear
Analog Inputs
Optional Analog Output
and Square Root
Extraction (Consult
Sales)
Optional 16 Point
Linearization
DP-F30 Ratemeter/Totalizer
Ideal for use with all OMEGA mass
flowmeters, controllers, turbine and
paddlewheel flow sensors, vortex
meters, magmeter and pitot tubes.
Includes DC Power
Output
Separate K-Factors for
Rate and Total
DP-F30 Series
The DP-F30 Ratemeter/Totalizer
accepts 3-30 Vdc pulses, dry
contact closure, voltage, or milliamp
inputs, and provides two stage
SPDT relay outputs for batch
control. The display is fully scalable
for engineering units and may be
toggled between batch total, rate,
and grand total. The linearization
option allows the user to select up
to 16 different K-factors over the
input range for accurate indication
of non-linear signals.
Other features include: 12 to 24
Vdc output for powering up
flowmeters; pulsed (.1 to 9.9 sec.)
or maintained outputs; input filtering
for dry contact closure (such as
reed relays); local/remote reset
enable; supplies excitation for open
collector or mechanical contacts;
programmable for auto-reset of
batch total (repeat cycles, 10 Hz
max.); security lockout to prevent
unauthorized changes; factored
pulse output; analog output for
rate or total. (Analog output
not available with square root
-SQRT option.)
The DP-F30 series indicates rate
to 51⁄2 digits and total to 8 digits, with
program and count data stored for
up to 10 years if power is lost.
SPECIFICATIONS DP-F30
Input Power: 110 Vac ±15% or 12 to 27
Vdc std; 220 Vac ±15% optional
Current:
Maximum 250 mA dc or 3.2 VA
Output Power: (on ac powered units
only): +24 or +12 Vdc @ 100 mA;
unregulated (±5% worst case)
Pulse Inputs: DP-F31: 0 to 1 Vdc (low),
3 to 30 Vdc (High) 20 KHz max. (min.
on/off 35µsec.) DP-F32: Has 4.7K ohm
pull up to +5 Vdc on input for pulsing
with contact to ground or NPN
collector transistor.
Factored Output:
Min. ON/OFF: .013 msec
Open collector sinks 100 mA maximum
from 1 volt to 30 Vdc maximum.
Maximum factored count speed
is 20 KHz.
Analog Input Impedance: 250 Ohm for
4-20 and 0-20 mA inputs; 15K ohm for
0-5, 1-5, and 0-10 Vdc inputs
Temperature: Operating: 32 to 130°F
Storage: -40 to 200°F
Accuracy: ±0.5% FS
Relay Outputs: Two SPDT Contacts
rated for 10 A at 120/230 Vac or 28 Vdc
4-20 mA Output: ±0.5% FS accuracy.
Requires 3-24 Vdc supply voltage,
noninductive
M-23
$
524
Basic Unit
MADE IN
USA
FC-20 MASS FLOW/BTU
COMPUTER
The FC-20 microprocessor
based Mass Flow/BTU Computer
is used with liquid, gas, or steam
flowmeters to indicate true mass
flow by correcting for changes in
fluid density. Or, model FC-20 can
be used to calculate BTU flowrate
for any fluid. It features direct input
of 100 ohm platinum RTD’s
(E curve), and has an integral
24 Vdc power supply for powering
up pressure and flow transmitters
(4-20 mA, 0-5 Vdc, or 0-10 Vdc
outputs). For flow input, the unit
can also accept 3 to 30 Vdc high
level square wave pulse inputs
(field selectable). For outputs,
the unit has a 4-20 mA output
proportional to mass flow rate
and a TTL level pulse output
proportional to mass flow total.
Both outputs are fully scalable.
The FC-20 also has a multifunction alarm and a separate flow
rate alarm relay.
LOW COST MASS FLOW/BTU COMPUTER
with Optional RS-232
Computer Interface Capability
Model FC-20
FC-20 displays directly in
engineering units, and stores
program and count data for more
than 10 years if power is lost.
For steam measurement, steam
tables from 14.7 to 3200 PSIA
and from saturation to 850°F of
superheat are used. For saturated
steam, a single temperature or
pressure input can be used. For
gases, the ideal gas law is used.
The FC-20 is fully programmable
through its NEMA 4X-rated front
keypad. A five digit lockout code
can be used to prevent
unauthorized reprogramming.
The FC-20 indicates up to six digits
while total is indicated up to 13
digits, after which the unit displays
in scientific notation.
SPECIFICATIONS FC-20
Input Power: 115/230 Vac ±15%
switch selectable; 10 watts maximum,
20-28 Vdc optional, FC-20 is field
selectable for 115 Vac or 230 Vac
power input.
Output Power: +24 Vdc @ 100 mA
Digital Input (For Flow Only): LEVEL:
3 to 30 Vdc Hi; 0-1 Vdc Low; 10 µsec
minimum pulse width, 20 KHz max.
Analog Input Impedance: 100 ohms
for mA, 100 K ohms for Vdc
Pulse Output: High; 4 Volts Min. Low:
1 Volt Max. Squarewave, Symmetrical
above 1 KHz, 100 msec pulse below
1 KHz 4 Hz.
$
872
MADE IN
USA
Relay Outputs: Two SPDT, Contacts
for 10 A at 120/230 Vac or 12 Vdc
Temperature: Operating: 32 to 122°F
(0 to 50°C). Storage: -10 to 60°F
(-30 to 185°C). Accuracy: ±.25% FS
4-20 mA Output: ±0.5% FS accuracy.
Requires 3-24 Vdc supply voltage,
noninductive
Compensated Flowrate Accuracy:
0.25% FS
Accepts Pulse, Linear or
Square Root Analog
Signals Standard
Compensates Liquids,
Steam and Gas for
Temperature and
Pressure
Integral 24 Vdc Power
Supply for Transmitters
Accepts RTD Input
Directly
Calculates BTU’s for
Liquids, Steam and Gas
16 Point Linearization
Standard
FC-20 Comes Standard
with 4-20 mA Output
MOST POPULAR MODELS HIGHLIGHTED!
To Order (Specify Model Number)
Model No.
DP-F31
DP-F32
DP-F33
DP-F34
FC-20
Price
$524
524
607
607
872
Description
Ratemeter/Totalizer
Ratemeter/Totalizer
Ratemeter/Totalizer
Ratemeter/Totalizer
Mass Flow/BTU computer
Input Type
Hi-level pulses
Dry relay pulses
4-20 mA
0-5 Vdc
Pulse or analog
Field selectable
Add suffix “-220 VAC” for 220 Vac power unit. No charge. Add suffix “-RS232” or “-RS422” for
computer communication option, and add $130 to price of DP-F30 unit, add $96 to price of
FC-20. For DP-F30, add suffix “-SQRT” for square root extraction, add suffix “-MA” for 4-20
mA output, add suffix “-LIN” for 16 point linearization. Add $158 for “-SQRT”, $118 for “-MA”,
$57 for “-LIN”.
Ordering Example: DP-F33-RS232 a ratemeter/totalizer with 4-20 mA input, and RS232
computer communications option, $607 + 130 = $737.
M-24