* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Parallel circuit heating tape HSB
Survey
Document related concepts
Transcript
Self-limiting parallel circuit heating tape HSB Features Description þ Steam cleaning possible þ Self-limiting þ Can be used in explosive atmospheres A temperature-dependant resistive element between two parallel copper conductors regulates and limits the heat output of the heating tape. This output regulation is carried out automatically along the entire length of the heating tape according to the prevailing ambient temperature. As the ambient temperature rises, the heat output of the tape is reduced. This self-limiting property prevents overheating even when the tapes are overlapped. A temperature limiter is not required (not even in explosion hazard zones). Thanks to the parallel power supply the heating tape can be cut to any required length. This feature considerably simplifies project planning and installation. The heating tape is cut and terminated in accordance with the local requirements directly on the construction site. In cases where the tape may become damaged, it is not necessary to replace the whole circuit but only the affected part. BARTEC-HEAT HSB is available in different versions and with different power outputs. without temperature limiter (subject to âTâ class) þ Can be cut to length at random thanks to its parallel circuit configuration þ Simple installation thanks to its high Parallel circuit heating tape HSB flexibility þ Easy on-site cutting and terminating, even in Ex areas þ Corrosion-proof and resistant to chemical attack thanks to its protective outer jacket 1 . Conductors: stranded copper busbars, 1.2 mm2, nickel plated 2 . Self-limiting synthetic polymer heating element 3 . Fluoropolymer electrical insulation jacket Application 4 . Tinned copper braiding Basic versions 2..C Order no. 07-5803-2..C With a fluoropolymer insulation jacket without Cu braiding or protective outer jacket, these basic versions are used on earthed pipes in non-explosive atmospheres. Version 2..A Order no. 07-5803-2..A With a Cu braiding and a protective outer jacket of fluoropolymer, this version is used when the heating cable is exposed to extreme amounts of moisture, strong chemical attacks or additional mechanical stress. Resistance to chemicals With a fluoroplastic protective outer jacket, this version is resistant to acids, lye, salt, salt water, oils and other hydrocarbon liquids. 03-0330-0237-10/99-BEH-E201984/3E 5 . Protective jacket of fluoropolymer 5/20 Self-limiting parallel circuit heating tape HSB Heat output W/m HSB characteristics 80 Technical data Nominal voltage 230 V Type of heating tape Heat output at + 10 °C 70 HSB 60 HSB 10 HSB 15 HSB 25 HSB 30 HSB 45 HSB 60 9.1 W/m 15.1 W/m 24.4 W/m 30.8 W/m 47.2 W/m 63.6 W/m Maximum exposure temperature allowed switched on (energised) switched off (1000 cumulative hours) +120 °C +190 °C Minimum installation temperature 60 -30 °C Max. length of heating circuit (for automatic circuit breakers with C characteristics) 50 16 A, cut-in temperature +10 °C 16 A, cut-in temperature -20 °C 200 m 200 m 153 m 143 m 107 m 102 m 92 m 82 m 66 m 61 m 50 m 45 m 20 A, cut-in temperature +10 °C 20 A, cut-in temperature -20 °C 200 m 200 m 189 m 179 m 133 m 128 m 112 m 102 m 82 m 77 m 60 m 55 m HSB 45 Max. resistance of protective braid <18.2 Ohm/km Thermal safety according to EN 60519-2; 1993 40 class 0 Temperature class (according to EN 50014) T3 Dimensions HSB 30 30 HSB 25 of non explosion-proof version without protective braid or without protective outer jacket of explosion-proof version with protective braid and protective outer jacket of fluoropolymer 8.7 x 3.1 mm 10.2 x 4.8 mm Min. bend radius 20 25 mm HSB 15 10 HSB 10 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Pipe temperature °C Heat output on insulated steel pipes at 230 V under nominal conditions Selection chart Type of heating tape Code HSB 10 10 HSB 15 15 Structure with protective braiding, Code A 03-0330-0237-10/99-BEH-E201984/4E with protective fluoropolymer outer jacket HSB 25 25 HSB 30 30 HSB 45 45 HSB 60 60 without protective braiding, Complete order no. without protective outer jacket C 07-5803-2 please fill in code 5/21 1 2 3 4 5