Self-limiting parallel circuit heating tape HSB
Features
Description
þ Steam cleaning possible
þ Self-limiting
þ Can be used in explosive atmospheres
A temperature-dependant resistive element between two parallel copper conductors regulates
and limits the heat output of the heating tape. This
output regulation is carried out automatically
along the entire length of the heating tape according to the prevailing ambient temperature. As the
ambient temperature rises, the heat output of the
tape is reduced. This self-limiting property prevents overheating even when the tapes are overlapped. A temperature limiter is not required (not
even in explosion hazard zones).
Thanks to the parallel power supply the heating
tape can be cut to any required length. This feature considerably simplifies project planning and
installation. The heating tape is cut and terminated
in accordance with the local requirements directly
on the construction site. In cases where the tape
may become damaged, it is not necessary to replace the whole circuit but only the affected part.
BARTEC-HEAT HSB is available in different versions and with different power outputs.
without temperature limiter (subject to ‘T’ class)
þ Can be cut to length at random thanks to its
parallel circuit configuration
þ Simple installation thanks to its high
Parallel circuit
heating tape HSB
flexibility
þ Easy on-site cutting and terminating, even
in Ex areas
þ Corrosion-proof and resistant to chemical
attack thanks to its protective outer jacket
1 . Conductors:
stranded copper busbars, 1.2 mm2,
nickel plated
2 . Self-limiting synthetic polymer
heating element
3 . Fluoropolymer electrical insulation jacket
Application
4 . Tinned copper braiding
Basic versions 2..C
Order no. 07-5803-2..C
With a fluoropolymer insulation jacket without Cu
braiding or protective outer jacket, these basic
versions are used on earthed pipes in non-explosive atmospheres.
Version 2..A
Order no. 07-5803-2..A
With a Cu braiding and a protective outer jacket
of fluoropolymer, this version is used when the
heating cable is exposed to extreme amounts of
moisture, strong chemical attacks or additional
mechanical stress.
Resistance to chemicals
With a fluoroplastic protective outer jacket, this
version is resistant to acids, lye, salt, salt water,
oils and other hydrocarbon liquids.
03-0330-0237-10/99-BEH-E201984/3E
5 . Protective jacket of fluoropolymer
5/20
Self-limiting parallel circuit heating tape HSB
Heat output W/m
HSB characteristics
80
Technical data
Nominal voltage
230 V
Type of heating tape
Heat output at + 10 °C
70
HSB 60
HSB 10
HSB 15
HSB 25
HSB 30
HSB 45
HSB 60
9.1 W/m
15.1 W/m
24.4 W/m
30.8 W/m
47.2 W/m
63.6 W/m
Maximum exposure temperature allowed
switched on (energised)
switched off (1000 cumulative hours)
+120 °C
+190 °C
Minimum installation temperature
60
-30 °C
Max. length of heating circuit (for automatic circuit breakers with C characteristics)
50
16 A, cut-in temperature +10 °C
16 A, cut-in temperature -20 °C
200 m
200 m
153 m
143 m
107 m
102 m
92 m
82 m
66 m
61 m
50 m
45 m
20 A, cut-in temperature +10 °C
20 A, cut-in temperature -20 °C
200 m
200 m
189 m
179 m
133 m
128 m
112 m
102 m
82 m
77 m
60 m
55 m
HSB 45
Max. resistance of protective braid
<18.2 Ohm/km
Thermal safety
according to EN 60519-2; 1993
40
class 0
Temperature class (according to EN 50014)
T3
Dimensions
HSB 30
30
HSB 25
of non explosion-proof version
without protective braid or without protective outer jacket
of explosion-proof version
with protective braid
and protective outer jacket of fluoropolymer
8.7 x 3.1 mm
10.2 x 4.8 mm
Min. bend radius
20
25 mm
HSB 15
10
HSB 10
0
0 10 20 30 40 50 60 70 80 90 100 110 120
Pipe temperature °C
Heat output on insulated steel pipes at 230 V under nominal conditions
Selection chart
Type of
heating tape
Code
HSB 10
10
HSB 15
15
Structure
with protective braiding,
Code
A
03-0330-0237-10/99-BEH-E201984/4E
with protective fluoropolymer outer jacket
HSB 25
25
HSB 30
30
HSB 45
45
HSB 60
60
without protective braiding,
Complete order no.
without protective outer jacket
C
07-5803-2
please fill in code
5/21
1
2
3
4
5