Series LCM Central Battery System Local Branch Circuit Monitoring LCM.12.11.06 EMERGENCY LIGHTING CIRCUITS MONITORING CENTRAL BATTERY SYSTEM LINE POWER UTILITY/ LINE POWER LCM PANEL ACTIVATION GENERAL LIGHTING PANEL GENERAL DESCRIPTION CONSTRUCTION & OPERATION The LCM panel monitors the status of up to eight (8) branch circuits for normally-on or general lighting. If any monitored circuit breaker is opened, the LCM will send a signal to a Central Battery System to activate emergency lighting in the area normally illuminated from the monitored circuit. Where required, the LCM enables compliance with NFPA Life Safety Code 101 (2009), Para 7.9.2.3, which states: • NEMA Type 1, UL 50 steel enclosure for surface (wall) mount, optional recess mount. • Up to (8) relay switches with normally open contacts. • Upon loss of power from any monitored circuit breaker, a 12VDC signal is sent to a CBS panel containing an emergency transfer switch, to activate emergency lighting. ELECTRICAL The emergency lighting system shall be arranged to provide the required illumination automatically in the event of any interruption of normal lighting due to any of the following: (1) (2) (3) Failure of public utility or other outside electrical power supply. Opening of a circuit breaker or fuse. Manual act(s), including accidental opening of a switch controlling normal lighting facilities. • Input 120 VAC (optional 277VAC) • Max 5 watts power consumption in normal mode. • Up to eight sensing relays are UL Recognized and rated for continuous duty. • The output circuit to a CBS may be installed using #22AWG NEC/Class 2 wiring. CODES • Operation Complies with requirements of NFPA Life Safety Code 101 (2009), Para 7.9.2.3.(2) and (3). D E S I G N E D & M A N U F A C T U R E D FIXTURE SCHEDULE MODEL APPROVAL I N T H E U S A CATALOG NO JOB INFORMATION Signtex Inc LIGHTING SPECIFIED EMERGENCY LIGHTING Series LCM Central Battery System Local Branch Circuit Monitoring LCM.12.11.06 SUGGESTED SPECIFICATION OPTIONS CODE Supply and install Signtex Local Circuit Monitoring Panel Series LCM which shall be capable of monitoring up to eight (8) branch circuits for normally-on or general lighting. Monitoring circuits to the lighting panel shall operate at 120VAC, or optionally at 277VAC. Upon failure or opening of any monitored circuit breaker, the LCM will signal a Signtex Series CBS Central Battery System to activate emergency lighting in the area normally illuminated from the monitored circuit. No. of Circuits Recess Mount Key Lock 277 VAC Input 1-8 REC LOK 277 INSTALLATION DATA & DIMENSIONS EMERGENCY LIGHTING CIRCUITS ZONE A,B,C 120 VAC*, 1PH * 277 VAC OPTION L N G CB1 BATT 1 2 3 4 5 6 30A SWITCH PANEL 12V NORMAL LIGHTING CIRCUITS ZONE A,B,C AC MONITORED CIRCUITS (1-8) 120 VAC (LINE) 277 VAC OPTION LCM1 DC 1/2 A AC (1-8) N G A LIGHTING DISTRIBUTION PANEL B 12 VDC 22 AWG (1000 Ft + TYP) LEGEND: C CBS1 CENTRAL BATTERY SYSTEM: #1 LCM1 LOCAL CIRCUIT MONITOR #1 DC 1/2 A AC (8) N BRANCH AC CIRCUIT MONITOR SWITCH, QTY (1-8) BATT 30A EMERGENCY LOAD TRANSFER SWITCH LCM PANEL 10" ORDERING INFORMATION EXAMPLE: LCM4-277-LOK LCM -5 -277 -LOK Local Circuit Monitor No. of Circuits Input AC Volts Options Local Circuit Monitor 1-8 120 277 SEE ABOVE Signtex Inc LIGHTING 10" 220 VFWAvenue, Grasonville, MD21638 TEL:(410)827-8300 Fax:(410)827-8866 [email protected] www.signtexinc.com DISTRIBUTOR: 4"