Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
60W Multiple-Stage Output Current LED Power Supply LCM-60DA series ■ Features : Output current level selectable by DIP S.W. 180~295VAC input only Built-in active PFC function Protections: Short circuit / Over voltage / Over temperature Cooling by free air convection Fully isolated plastic case Class Ⅱ power unit, no FG Built-in DALI interface and push dimming function Optional 12V/50mA auxiliary output (Model No.: LCM-60DA-AUX) IP20 design Logarithm or linear dimming curve selectable(Meet IEC62386-207) Temperature compensation function by external NTC No load power consumption <0.5W(<1.2W for LCM-60DA-AUX)(Note.7) Power supplies synchronization function up to 10 units Suitable for indoor LED lighting applications 3 years warranty F 110 M M SPECIFICATION MODEL OUTPUT SELV LCM-60DA SELECTABLE CURRENT Note.3 500mA 600mA 700mA 900mA 1050mA 1400mA DC VOLTAGE RANGE 2 ~ 90V 2 ~ 90V 2 ~ 86V 2 ~ 67V 2 ~ 57V 2 ~ 42V RATED POWER 60.3W RIPPLE CURRENT ±5% RIPPLE & NOISE (max.) Note.2 700mVp-p NO LOAD OUTPUT VOLTAGE (max.) 95V ±5.0% CURRENT ACCURACY SETUP, RISE TIME Note.5 500ms, 80ms / 230VAC at rated power 16ms/230VAC at rated power HOLD UP TIME (Typ.) VOLTAGE RANGE INPUT Note.4 180 ~ 295VAC 254 ~ 417VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF≧0.975/230VAC, PF≧0.96/277VAC at rated power (Please refer to "Power Factor Characteristic" curve) TOTAL HARMONIC DISTORTION Total harmonic distortion will be lower than 20% when output loading is 75% or higher EFFICIENCY (Typ.) Note.6 92% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.32A/230VAC 0.27A/277VAC COLD START 20A(twidth=270μs measured at 50% Ipeak) at 230VAC MAX. No. of PSUs on 16A CIRCUIT BREAKER LEAKAGE CURRENT 25 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC SHORT CIRCUIT PROTECTION OVER VOLTAGE OVER TEMPERATURE FUNCTION 73V <0.5mA / 240VAC Constant current limiting, recovers automatically after fault condition is removed 105 ~ 125V Protection type : Shutdown o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover AUXILIARY POWER (optional) 12V @ 50mA for driving fan; Tolerance±5% By external NTC(not provide with the power supply), please see "Temperature compensation operation" TEMP. COMPENSATION DIMMING Please see "Dimming Operation" SYNCHRONIZATION Please see "Synchronization Operation" WORKING TEMP. -30 ~ +60℃ (Refer to "Derating Curve") WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION 20 ~ 90% RH non-condensing -40 ~ +80℃, 10 ~ 95% RH ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL8750, CSA C22.2 No.250.13-12, ENEC EN61347-1, EN61347-2-13, EN62384 independent,GB19510.14,GB19510.1 approved DALI STANDARDS Comply with IEC62386-101, 102, 207 SAFETY & WITHSTAND VOLTAGE I/P-O/P:3.75KVAC EMC I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55015, EN61000-3-2 Class C(≧40% rated power) ; EN61000-3-3; GB17625.1,GB17743 ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2KV), criteria A 193.6K hrs min. MIL-HDBK-217F (25℃) 123.5*81.5*23mm (L*W*H) 0.24Kg ; 54pcs/15Kg/1.12CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf parallel capacitor. 3. Please see "DIP switch table". 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. Efficiency is measured at 900mA/67V output set by DIP switch. 7. No load power consumption<0.5W(LCM-60DA) and <1.2W(LCM-60DA-AUX) is measured at 180~230VAC, with lighting fixture connected and output current dimmed to 0%. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. File Name:LCM-60DA-SPEC 2016-04-07 LCM-60DA 60W Multiple-Stage Output Current LED Power Supply Mechanical Specification Case No.LCM-60A series Unit:mm 123.5 6.75 110 6.75 ※ T case: Max. Case Temperature. 1 2 6.75 4.2 3 2- 40 TB1 T case 4 5 68 1 2 3 4 SYN. 1 CN101 2 3 CN100 4 TB3 1 2 TB5 ON 1 2 3 4 5 6 Bottom View Terminal Pin No. Assignment(TB3) 39.3 65.5 Pin No. 1 2 7.8 2-M3 Assignment +FAN(optional) -FAN(optional) Pin No. 3 4 Assignment +NTC -NTC 4 7.8 Terminal Pin No. Assignment(TB5) Assignment +Vo -Vo 23 Pin No. 1 2 SYN. Connector(CN101/CN100):JST B2B-XH or equivalent Terminal Pin No. Assignment(TB1) Assignment AC/L AC/N PUSH Pin No. 1 2 3 Pin No. 4 5 Pin No. 1,3 2,4 Assignment DA+ DA- Assignment + - Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent PFC fosc : 60KHz PWM fosc : 80KHz Block Diagram EMI FILTER & RECTIFIERS I/P POWER SWITCHING PFC CIRCUIT RECTIFIERS +12Vaux (optional) RECTIFIERS & FILTER +V -V DIM+ DIM- CURRENT LIMIT PWM CONTROL O.T.P. MCU DETECTION CIRCUIT O.L.P. PFC CONTROL O.V.P. Derating Curve Static Characteristics 100 100 Others 90 80 80 70 40 LOAD (%) 60 LOAD (%) 81.5 15 6.75 1050mA / 1400mA 20 -30 -15 0 15 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 (HORIZONTAL) 60 50 40 180 190 200 210 220 230 240 250 260 270 280 295 INPUT VOLTAGE (V) 60Hz File Name:LCM-60DA-SPEC 2016-04-07 60W Multiple-Stage Output Current LED Power Supply LCM-60DA series DIP Switch Table LCM-60DA is a multiple-stage output current supply, selection of output current through DIP switch as table below. DIP S.W. 1 2 3 4 5 6 500mA ---- ---- ---- ---- ---- ---- 600mA ON ---- ---- ---- ---- ---- 700mA(Factory Setting) ON ON ---- ---- ---- ---- 900mA ON ON ON ---- ---- ON 1050mA ON ON ON ON ---- ON 1400mA ON ON ON ON ON ON Io Power Factor Characteristic Constant Current Mode Constant Current Mode 1.00 0.97 0.94 500 0.88 600 0.85 700 0.82 900 0.79 1050 PF PF 0.91 1400 0.76 0.73 0.70 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% (60W) 1.00 0.97 0.94 0.91 0.88 0.85 0.82 0.79 0.76 0.73 0.70 0.67 0.64 0.61 0.58 0.55 0.52 0.49 500 600 700 900 1050 1400 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% (60W) LOAD (230Vac Input) LOAD (277Vac Input) EFFICIENCY vs LOAD 95.0% 95.0% 90.0% 90.0% 85.0% 85.0% 80.0% 500 75.0% 600 700 70.0% 900 65.0% 1050 60.0% 1400 55.0% EFFICIENCY (%) EFFICIENCY (%) LCM-60DA series possess superior working efficiency that up to 92% can be reached in field applications. 80.0% 500 75.0% 600 70.0% 700 65.0% 900 60.0% 1050 55.0% 1400 50.0% 45.0% 50.0% 40.0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD (230Vac Input) 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD (277Vac Input) File Name:LCM-60DA-SPEC 2016-04-07 60W Multiple-Stage Output Current LED Power Supply LCM-60DA series DIMMING OPERATION ※PUSH dim(primary side) Ignore To avoid reaction on AC spike Short push Push to turn ON-OFF <0.05 sec. 0.1~1 sec. Long push Dimming up or down 1.5~10 sec. Reset push Setting light to 100% >11 sec. Maximum number of drivers up to 10 pcs. Maximum length of the cable, from push button to last driver is 20 meter. Factory setting at 100%. Every long pushing action will change the dimming direction. • LCM-60DA DADA+ PUSH AC/N AC/L Push Button AC/N AC/L Warning: The pushbutton can only be connected in between the PUSH terminal of LCM-60DA and AC/L (brown or black color). It would cause short circuit if it is connected to AC/N. ※DALI interface(primary side) DALI protocol including 16 groups and 64 addresses. First step is fixed at 6% of output. SYNCHRONIZATION OPERATION 10 drivers(max.) synchronization (1 master + 9 slaves) Maximum cable length between each units : 20 meter. 20m SYN. - - LCM-60DA (Slave 1) SYN. - - + + LCM-60DA (Master) + + SYN. - - + + LCM-60DA (Slave 2) 20m NOTE: Please make sure all units are set to 100% dimming setting(factory default) before synchronizing. File Name:LCM-60DA-SPEC 2016-04-07 60W Multiple-Stage Output Current LED Power Supply LCM-60DA series TEMPERATURE COMPENSATION OPERATION NTC derating curve 105 100 220KΩ 220KO Output Io (%) 95 330KO 330KΩ 470KO 470KΩ 90 85 80 75 70 65 55 60 65 70 75 80 85 90 95 Sensed Temperature(degree) LCM-60DA have the built-in temperature compensation function (T↑,Io↓). By connecting a temperature sensor (NTC resistor) between the NTC +/terminal of LCM-60DA and the detecting point on the lighting system or the surrounding environment, output current of LCM-60DA could be correspondingly changed to ensure the long life of LED. 1.LCM-60DA can still be operated well when the NTC resistor is not connected and the value of output current will be the current level that you set through the DIP switch. 2. NTC resistance Output Current 220K < 60℃, 100% of the rated current (corresponds to the setting current level) > 60℃, output current begin to reduce, details please refer to the curve. 330K < 70℃, 100% of the rated current (corresponds to the setting current level) > 70℃, output current begin to reduce, details please refer to the curve. 470K < 80℃, 100% of the rated current (corresponds to the setting current level) > 80℃, output current begin to reduce, details please refer to the curve. Notes: 1. MW does not offer the NTC resistor and all the data above are measured by using THINKING TTC03 series. 2. If other brands of NTC resistor is applied,please check the temperature curve first. 3. Synchronization function of the power supply will be invalid when the" temperature compensation function" is in use. File Name:LCM-60DA-SPEC 2016-04-07