Download Process Signal Integrator DIN400 AlphaDIN - Lee

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Oscilloscope types wikipedia , lookup

Oscilloscope wikipedia , lookup

Surge protector wikipedia , lookup

Power dividers and directional couplers wikipedia , lookup

Flip-flop (electronics) wikipedia , lookup

Audio power wikipedia , lookup

Time-to-digital converter wikipedia , lookup

Oscilloscope history wikipedia , lookup

Ohm's law wikipedia , lookup

Power MOSFET wikipedia , lookup

CMOS wikipedia , lookup

Negative-feedback amplifier wikipedia , lookup

Amplifier wikipedia , lookup

Voltage regulator wikipedia , lookup

Wilson current mirror wikipedia , lookup

Integrating ADC wikipedia , lookup

Multimeter wikipedia , lookup

Analog-to-digital converter wikipedia , lookup

Valve audio amplifier technical specification wikipedia , lookup

Radio transmitter design wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Transistor–transistor logic wikipedia , lookup

Current mirror wikipedia , lookup

Power electronics wikipedia , lookup

Schmitt trigger wikipedia , lookup

Operational amplifier wikipedia , lookup

Valve RF amplifier wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Opto-isolator wikipedia , lookup

Rectiverter wikipedia , lookup

Transcript
Ch.04_v1
12/9/05
12:37 pm
Page 7
AlphaDIN
CONVERTERS
Process Signal Integrator DIN400
Function: Precision electronic instrument for the integration of electrical
quantities against time giving a 24 Volt DC pulse and an open collector output
suitable for operation of an electro-mechanical impulse counter, etc. The
DIN400 can be used for any application where time-varying signals require
integrating. For instance:– Flow, Mass Flow (Liquids, Solids or Gases), Electric
Charge, etc.
Application Notes: If the DIN400 is required to work from low level signals
then it can be preceded by a BD300 signal amplifier. Similarly the DIN400 can
accept square law signals from differential pressure/flow transmitters if
preceded by a DIN500 Square Root Extractor.
SPECIFICATIONS
Please note that the following are
typical ranges. We also
manufacture instruments to cater
for other ranges, within limitations
detailed below. All instruments
come with span and zero
potentiometers for fine tuning on
site.
INPUTS:
DC Current
0 to 1mA into 100 ohms
0 to 10mA into 10 ohms
4 to 20mA into 10 ohms
10 to 50mA into 10 ohms
Other ranges as required
DC Voltage
Between 0 and 250 Volts DC
Minimum voltage span 100 mV
Maximum voltage span 250 Volts
Input Impedance
100K ohm or greater for inputs of
greater than 1 Volt DC
OUTPUTS:
SUPPLY:
GENERAL:
Output Pulse
1) 24 Volt DC 40mS wide, derived
from an Open Collector and
internal supply, and
2) Opto Coupler, 40mS wide
Maximum sink current 5mA
Maximum voltage 30 Volts
Isolated from input and supply
Power Supply Voltage
User selectable
115 Volt AC ±15% 50/60 Hz
230 Volt AC ±15% 50/60 Hz
Linearity Error
Pulse rate proportional to input
±0.1% of span
Output Count Rate
Minimum 120 counts per hour
2 counts per minute
Maximum 12,000 counts per hour
200 counts per minute
– internally switch selectable
Terminal
1
Input –ve
2
Input +ve
3
Test Point
4
5
6
Counter Output –ve
7
Counter Output +ve
1
7
8
14
75.0
Operating Temperature Range
0 to +50ºC
Storage Temperature Range
–20 to +60ºC
Operating Humidity Range
0 to 95% RH non-condensing
Storage Humidity Range
0 to 95% RH non-condensing
Weight
320 gms
Opto Coupler Output
35.0
7
Temperature Coefficient
±0.1% of span / 10ºC
TERMINATION DETAILS
110.0
1
Pilot Light
Red LED shows Power ON
Loading
150 ohms minimum DC resistance
160mA maximum suitable for one
electro-mechanical counter
MECHANICAL DETAILS
45.0
Power Required
3VA Maximum
Terminal
8
Unused
9
Unused
10
Unused
11
Unused
12
230 Volt ±15% 50/60 Hz
13
115 Volt ±15% 50/60 Hz
14
Neutral
ORDERING DETAILS
a)
b)
c)
Give identification code, i.e. DIN400
Give all details of input signal, both type and range, i.e. 4 to 20mA
Give details of output count rate required, i.e. 0 to 250 counts per hour
LEE -DICKENS LTD
Desborough, Kettering, Northants NN14 2QW U.K.
Te l : ( 0 1 5 3 6 ) 7 6 0 1 5 6 F a x ( 0 1 5 3 6 ) 7 6 2 5 5 2
4.6