EAC FT EAC FTt EAC 3FT
Product Information
Intended Use
An off-line AC power
system for the
emergency operation of
HID, incandescent and
fluorescent emergency
lighting loads that
provides full light
output for 90 minutes of
operation.
FT and 3FT have a 65K amp
inrush current rating.
Sinusoidal output
waveform has <3% THD.
Off-line uninterruptable
system has 2-millisecond
transfer time.
Standard circuit
protection: low-voltage
disconnect, short-circuit
protection, currentlimiting, fused-battery
protection, brownout
protection, input circuit
breaker.
Construction
Free-standing NEMA
Type 1 cabinet.
Microprocessorcontrolled PWM inverter
with IGBT technology
allows for universal
compatibility.
Standard RS232
diagnostic interface on FT
and 3FT.
EAC FT output ratings:
1,500 VA to 16,700 VA.
Single- phase system.
Listings
UL Listed (standard) for
90 minutes of emergency
operation.
EAC 3FT output ratings:
4,800 VA to 50,000 VA.
Three-phase system.
Meets NFPA 101, OSHA,
NEC and City of Chicago
Codes.
EAC FTT output ranges:
500 VA to 2000 VA.
Single-phase system.
Field upgradable (500 VA
system).
Example: EAC 3FT 6000 208 FSP
Lead times will vary depending on options selected. Consult with your sales representative.
Ordering Information
Series
Battery
System
VA rating
Voltage6
EAC Emergency
AC power
system
(blank) Lead-calcium,
10-year life
LC20 Lead-calcium,
20-year life1
FTT Compact
fast
transfer
FT Fast
transfer
3FT 3-phase
fast
transfer
5002
10002
15003
20002
22504
30004
37504
4800
6000
8000
Input/output
120/1203
277/2773
277/1204
120/120-2774
277/120-2774
2085
4805
10000
12500
16700
240005
330005
400005
500005
Notes
Options
(blank) None
Battery
12HR 12-hour
battery
recharge1
Supervisory
RMP Remote
meter
panel
MBYP Maintenance bypass switch7
XMBYP External maintenance bypass switch
Input/output
OB
Output circuit breaker (specify
quantity and amps)8
OTA
Output trip alarm
Miscellaneous
FSP
Factory start-up program
DFC
Form "C" contacts
NOFF Normally OFF output circuit9
MODEM External modem for RS232
For additional product information, visit www.lithonia.com.
1
2
3
4
5
6
Available on FT and 3FT only.
Available on FTT only.
Available on FTT and FT only.
Available on FT only.
Available on 3FT only.
Consult factory for other voltage requirements.
Special voltages may affect the weight, size and
number of cabinets.
7 Standard on 3FT.
8 Standard 20-amp normally on unless
otherwise specified.
9 Normally off load cannot exceed 20% of total VA
rating with any combination of HID loads.
Additional Information
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
10
(25.4)
1 2 3
4 5 6
7 8 9
0
47
(119.4)
10
(25.4)
30
(76.2)
25
(63.5)
EAC FT or EAC 3FT
10
(25.4)
26
(66.0)
EAC FTT
www.lithonia.com 1-800-334-8694
EAC iss
disconnect, short-circuit
protection, currentlimiting and brown-out
protection.
Features
Microprocessor-controlled
PWM inverter with IGBT
technology allows for
universal compatibility.
Systems 4KVA - 4800 and
below are self-contained.
Larger systems require
external, stackable battery
cabinets.
Standard RS232 interface
allows communication
with system from remote
computer. Low-voltage
Standard digital meter
panel displays input/output
voltage, battery voltage
and output current.
Stackable, modular cabinet
design enabling versatile
installation.
Product Information
Information
Product
Intended Use
Automatic standby
AC power systems
for incandescent and
fluorescent emergency
lighting loads that provide
full light output for 90
minutes of operation.
24-hour battery recharge
standard.
50-millisecond transfer
time.
Listings
UL 924 Listed for 90
minutes of emergency
operation.
Meets NFPA 101, OSHA,
NEC and City of Chicago
Codes.
Example: EAC ISS 1500 120/120 OB
Lead times will vary depending on options selected. Consult with your sales representative.
Battery
System
VA rating1
Voltage2
EAC Emergency AC
power system
(blank) Lead-calcium,
10-year life
LC20 Lead-calcium
battery, 20-year life
ISS Interruptible
1500
2250
3000
3750
4800
6000
8000
10000
12500
16700
Input/output
120/120
277/277
277/120
120/120-277
277/120-277
Options
Input/output
OB
Output circuit breaker (specify quantity and amps)3
OTA
Output trip alarm
Miscellaneous
FSP
Factory start-up program
RMP
Remote meter panel
MBYP Maintenance bypass switch
MODEM External modem RS232
DFC
Form "C" contact
For additional product information, visit www.lithonia.com.
(blank) None
Battery
12HR
12-hour battery recharge
Electronic
TD
Time delay (15 minutes)
47
(119.4)
30
(76.2)
25
(63.5)
EAC ISS
www.lithonia.com 1-800-334-8694
Notes
1 Systems 4800 (5KVA) or larger require external battery cabinets.
2 Consult factory for other voltages.
3 Standard 20-amp, normally on unless otherwise specified.
AdditionalInformation
Information
Additional
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
Ordering Information
Series
Related documents