Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
EAC FT EAC FTt EAC 3FT Product Information Intended Use An off-line AC power system for the emergency operation of HID, incandescent and fluorescent emergency lighting loads that provides full light output for 90 minutes of operation. FT and 3FT have a 65K amp inrush current rating. Sinusoidal output waveform has <3% THD. Off-line uninterruptable system has 2-millisecond transfer time. Standard circuit protection: low-voltage disconnect, short-circuit protection, currentlimiting, fused-battery protection, brownout protection, input circuit breaker. Construction Free-standing NEMA Type 1 cabinet. Microprocessorcontrolled PWM inverter with IGBT technology allows for universal compatibility. Standard RS232 diagnostic interface on FT and 3FT. EAC FT output ratings: 1,500 VA to 16,700 VA. Single- phase system. Listings UL Listed (standard) for 90 minutes of emergency operation. EAC 3FT output ratings: 4,800 VA to 50,000 VA. Three-phase system. Meets NFPA 101, OSHA, NEC and City of Chicago Codes. EAC FTT output ranges: 500 VA to 2000 VA. Single-phase system. Field upgradable (500 VA system). Example: EAC 3FT 6000 208 FSP Lead times will vary depending on options selected. Consult with your sales representative. Ordering Information Series Battery System VA rating Voltage6 EAC Emergency AC power system (blank) Lead-calcium, 10-year life LC20 Lead-calcium, 20-year life1 FTT Compact fast transfer FT Fast transfer 3FT 3-phase fast transfer 5002 10002 15003 20002 22504 30004 37504 4800 6000 8000 Input/output 120/1203 277/2773 277/1204 120/120-2774 277/120-2774 2085 4805 10000 12500 16700 240005 330005 400005 500005 Notes Options (blank) None Battery 12HR 12-hour battery recharge1 Supervisory RMP Remote meter panel MBYP Maintenance bypass switch7 XMBYP External maintenance bypass switch Input/output OB Output circuit breaker (specify quantity and amps)8 OTA Output trip alarm Miscellaneous FSP Factory start-up program DFC Form "C" contacts NOFF Normally OFF output circuit9 MODEM External modem for RS232 For additional product information, visit www.lithonia.com. 1 2 3 4 5 6 Available on FT and 3FT only. Available on FTT only. Available on FTT and FT only. Available on FT only. Available on 3FT only. Consult factory for other voltage requirements. Special voltages may affect the weight, size and number of cabinets. 7 Standard on 3FT. 8 Standard 20-amp normally on unless otherwise specified. 9 Normally off load cannot exceed 20% of total VA rating with any combination of HID loads. Additional Information Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted. 10 (25.4) 1 2 3 4 5 6 7 8 9 0 47 (119.4) 10 (25.4) 30 (76.2) 25 (63.5) EAC FT or EAC 3FT 10 (25.4) 26 (66.0) EAC FTT www.lithonia.com 1-800-334-8694 EAC iss disconnect, short-circuit protection, currentlimiting and brown-out protection. Features Microprocessor-controlled PWM inverter with IGBT technology allows for universal compatibility. Systems 4KVA - 4800 and below are self-contained. Larger systems require external, stackable battery cabinets. Standard RS232 interface allows communication with system from remote computer. Low-voltage Standard digital meter panel displays input/output voltage, battery voltage and output current. Stackable, modular cabinet design enabling versatile installation. Product Information Information Product Intended Use Automatic standby AC power systems for incandescent and fluorescent emergency lighting loads that provide full light output for 90 minutes of operation. 24-hour battery recharge standard. 50-millisecond transfer time. Listings UL 924 Listed for 90 minutes of emergency operation. Meets NFPA 101, OSHA, NEC and City of Chicago Codes. Example: EAC ISS 1500 120/120 OB Lead times will vary depending on options selected. Consult with your sales representative. Battery System VA rating1 Voltage2 EAC Emergency AC power system (blank) Lead-calcium, 10-year life LC20 Lead-calcium battery, 20-year life ISS Interruptible 1500 2250 3000 3750 4800 6000 8000 10000 12500 16700 Input/output 120/120 277/277 277/120 120/120-277 277/120-277 Options Input/output OB Output circuit breaker (specify quantity and amps)3 OTA Output trip alarm Miscellaneous FSP Factory start-up program RMP Remote meter panel MBYP Maintenance bypass switch MODEM External modem RS232 DFC Form "C" contact For additional product information, visit www.lithonia.com. (blank) None Battery 12HR 12-hour battery recharge Electronic TD Time delay (15 minutes) 47 (119.4) 30 (76.2) 25 (63.5) EAC ISS www.lithonia.com 1-800-334-8694 Notes 1 Systems 4800 (5KVA) or larger require external battery cabinets. 2 Consult factory for other voltages. 3 Standard 20-amp, normally on unless otherwise specified. AdditionalInformation Information Additional Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted. Ordering Information Series