Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
IS 212 Inductive switches Dimensioned drawing IS 212…-2E0-S12 IS 212…-4E0-S12 en 02-2010/03 50110220 IS 212…-6E0-S12 2 mm 4 mm 6 mm 10 - 30 V DC 3 kHz Embedded z Slim and short cylindrical metal housing M12 z Chromium-plated brass housing z Built-in short circuit protection, inductive protection and polarity reversal protection z LED for switching state visible from 360° Tightening torque of the fastening nuts < 10Nm ! We reserve the right to make changes • DS_IS_212_E_en.fm A B C UL Electrical connection US LISTED IEC 60947... IEC 60947... Active surface Yellow indicator diode Cable IP 67 Accessories: (available separately) z M12 connectors (KD … ) z Ready-made cables (K-D …) z Mounting clamp (MC 012…) M12 connector …NO… (normally open) …NO…-S12 (normally open): …NC…-S12 (normally closed): …NC… (normally closed) 3-pin or 4-pin M12 connection cables can be used. only 4-pin M12 connection cables can be used. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] IS 212 Specifications General specifications Type of installation Typ. operating range limit Sn Operating range Sa Tables IS 212…-2E0… IS 212…-4E0… embedded installation 2.0mm 4.0mm 0 … 1.6mm 0 … 3.2mm IS 212…-6E0… 6.0mm 0 … 4.8mm Electrical data Operating voltage UB 1) Residual ripple σ Output current IL Open-circuit current I0 Residual current Ir Switching output/function …/4NO… …/4NC… …/2NO… …/2NC… Voltage drop Ud Hysteresis H of Sr Temperature drift of Sr Repeatability 10 … 30VDC ≤ 20% of UB ≤ 200mA ≤ 10mA ≤ 100μA PNP transistor, make-contact (NO) PNP transistor, break-contact (NC) NPN transistor, make-contact (NO) NPN transistor, break-contact (NC) ≤ 2V ≤ 10% ≤ 15% ≤ 10% 2) ≤ 5% 3) ≤ 10% Reduction factors: for Sn = 2.0mm Steel Fe360 1 Copper 0.20 Aluminum 0.30 Brass 0.40 Stainless steel 0.85 for Sn = 6.0mm Steel Fe360 1 Copper 0.25 Aluminum 0.30 Brass 0.40 Stainless steel 0.70 for Sn = 4.0mm Steel Fe360 Copper Aluminum Brass Stainless steel 1 0.40 0.44 0.54 0.80 Mounting Embedded installation: Timing 3kHz ≤ 10ms 2kHz ≤ 300ms 800Hz ≤ 50ms ≥ 3Sn Indicators d switching state Mechanical data Housing Standard surface plate Active surface Weight (M12 plug/cable) Connection type chromium-plated brass 12 x 12mm², Fe360 12 x 12mm², Fe360 PBTP approx. 25g/ approx. 95g M12 connector 4-pin or cable: 2m, PVC, 3 x 0.34mm², Ø 5.0mm -25°C … +70°C IP 67 1, 2, 3 IEC/EN 60947-5-2 IEC 60255-5 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 d D3 18 x 18mm², Fe360 Environmental data Ambient temperature Protection class Protective circuit 4) Standards applied Electromagnetic compatibility D2 D1 d Yellow LED (visible from 360°) d Switching frequency f Delay before start-up ≥ 3Sn 1kV Level 3 air 8kV (ESD) Level 3 10V/m (RFI) Level 3 2kV (Burst) Ferromagnetic and non-ferromagnetic materials Sn [mm] D1 [mm] D2 [mm] D3 [mm] 2.0 4.0 6.0 0 0 2.0 6.0 12.0 18.0 2.0 4.0 6.0 1) Observe the safety regulations and installation instructions regarding power supply and wiring; for UL applications: only for use in "Class 2" circuits acc. to NEC 2) Over the entire operating temperature range 3) For UB = 20 … 30VDC, ambient temperature Ta = 23°C ± 5°C 4) 1=polarity reversal protection, 2=short circuit protection, 3=inductive protection for all outputs Order guide The sensors listed here are preferred types; current information at Leuze website. Designation Part No. Sn = 2mm IS 212 MM/4NO-2E0 IS 212 MM/4NO-2E0-S12 IS 212 MM/4NC-2E0-S12 IS 212 MM/2NO-2E0 50109664 50109665 50111870 50109666 Sn = 4mm IS 212 MM/4NO-4E0 IS 212 MM/4NO-4E0-S12 IS 212 MM/4NC-4E0-S12 IS 212 MM/2NO-4E0 50109672 50109673 50109674 50109675 Sn = 6mm IS 212 MM/4NO-6E0 IS 212 MM/2NO-6E0 50109678 50109682 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] IS 212 Inductive switches Diagrams Models with Sn = 2.0mm Models with Sn = 4.0mm Models with Sn = 6.0mm Inductive switch Inductive switch Inductive switch Standard surface plate Standard surface plate Standard surface plate Type key I S 2 1 2 M M / 4 N O - 4 E 0 - S 1 2 Operating principle / construction IS Inductive switch / Standard Series 212 Series with M12 x 1 external thread Housing / thread MM Metal housing (active surface: plastic) / metric thread Output function 4NO PNP transistor, make-contact (NO) 4NC PNP transistor, break-contact (NC) 2NO NPN transistor, make-contact (NO) 2NC NPN transistor, break-contact (NC) Measurement range / type of installation 2E0 Typ. scan range limit 2.0mm / embedded installation 4E0 Typ. scan range limit 4.0mm / embedded installation 6E0 Typ. scan range limit 6.0mm / embedded installation Electrical connection N/A Cable, PVC, standard length 2000mm S12 M12 connector, 4-pin, axial 200-S12 Cable, PVC, length 200mm with M12 connector, 4-pin, axial Remarks z Approved purpose: The inductive switches are electronic sensors for the inductive, contactless detection of objects. This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] ISS 212 Inductive switches Dimensioned drawing ISS 212…-10N-S12 Part No. 501 10221 ISS 212…-4N0-S12 4 mm 10 mm 10 - 30 V DC 400 Hz non-embedded z Slim and very short cylindrical metal housing M12 z Chromium-plated brass housing z Built-in short circuit protection, inductive protection and polarity reversal protection z LED for switching state visible from 360° Tightening torque of the fastening nuts < 10Nm ! A B We reserve the right to make changes • 212_04gb.fm C UL Electrical connection US LISTED IEC 60947... IEC 60947... Active surface Yellow indicator diode Cable IP 67 Accessories: (available separately) z M12 connectors (KD … ) z Ready-made cables (K-D …) z Mounting clamp (MC 012…) M12 connector …NO… (normally open) …NO…-S12 (normally open): …NC…-S12 (normally closed): …NC… (normally closed) 3-pin or 4-pin M12 connection cables can be used. only 4-pin M12 connection cables can be used. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] ISS 212 Specifications Tables General specifications Type of installation Typ. operating range limit Sn Operating range Sa ISS 212…-4N0… ISS 212…-10N… non-embedded installation 4.0mm 0 … 3.2mm 10.0mm 0 … 8.1mm Electrical data Operating voltage UB 1) Residual ripple σ Output current IL Open-circuit current I0 Residual current Ir Switching output/function Voltage drop Ud Hysteresis H of Sr Temperature drift of Sr Repeatability …/4NO… …/4NC… …/2NO… …/2NC… 10 … 30VDC ≤ 20% of UB ≤ 200mA ≤ 10mA ≤ 100μA PNP transistor, make-contact (NO) PNP transistor, break-contact (NC) NPN transistor, make-contact (NO) NPN transistor, break-contact (NC) ≤ 2V ≤ 10% ≤ 10% 2) ≤ 5% 3) ≤ 3% 3) Timing Switching frequency f Delay before start-up 2kHz ≤ 10ms Reduction factors: for Sn = 4.0mm Steel Fe360 1 Copper 0.50 Aluminum 0.50 Brass 0.60 Stainless steel 0.90 for Sn = 10.0mm Steel Fe360 1 Copper 0.41 Aluminum 0.46 Brass 0.52 Stainless steel 0.74 Mounting Non-embedded installation: ≥ 3Sn d D2 d D3 D1 400Hz ≤ 50ms Indicators Yellow LED (visible from 360°) switching state chromium-plated brass 12 x 12mm², Fe360 30 x 30mm², Fe360 PBTP approx. 30g/approx. 95g M12 connector 4-pin or cable: 2m, PVC, 3 x 0.34mm², Ø 5.0mm Environmental data Ambient temperature Protection class Protective circuit 4) Standards applied Electromagnetic compatibility -25°C … +70°C IP 67 1, 2, 3 IEC/EN 60947-5-2 IEC 60255-5 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 ≥ 3Sn Ferromagnetic and non-ferromagnetic materials Sn [mm] D1 [mm] D2 [mm] D3 [mm] 4.0 10.0 1kV Level 3 air 8kV (ESD) Level 3 10V/m (RFI) Level 3 2kV (Burst) d Housing Standard surface plate Active surface Weight (M12 plug/cable) Connection type d Mechanical data 6.0 10.0 16.0 30.0 6.0 10.0 Diagrams Models with Sn = 4.0mm 1) Observe the safety regulations and installation instructions regarding power supply and wiring; for UL applications: only for use in "Class 2" circuits acc. to NEC 2) Over the entire operating temperature range 3) For UB = 20 … 30VDC, ambient temperature Ta = 23°C ± 5°C 4) 1=polarity reversal protection, 2=short circuit protection, 3=inductive protection for all outputs Order guide Inductive switch The sensors listed here are preferred types; current information at leuze website. Sn = 10mm Designation Part No. ISS 212 MM/4NO-10N-S12 501 09680 Standard surface plate Models with Sn = 10.0mm Inductive switch Standard surface plate Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] ISS 212 Inductive switches Type key I S S 2 1 2 M M / 4 N O - 1 0 N - S 1 2 Operating principle / construction ISS Inductive switch / short construction Series 212 series with M12 x 1 external thread Housing / thread MM metal housing (active surface: plastic) / metric thread Output function 4NO PNP transistor, make-contact (NO) 4NC PNP transistor, break-contact (NC) 2NO NPN transistor, make-contact (NO) 2NC NPN transistor, break-contact (NC) Measurement range / type of installation 4N0 typ. scan range limit 4.0mm / non-embedded installation 10N typ. scan range limit 10.0mm / non-embedded installation Electrical connection N/A cable, PVC, standard length 2000mm S12 M12 connector, 4-pin, axial 200-S12 cable, PVC, length 200mm with M12 connector, 4-pin, axial Remarks z Approved purpose: Inductive switches are electronic sensors used for the inductive, contactless detection of objects. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] ISS 212 Inductive switches Dimensioned drawing ISS 212…-6E0-S12 Part No. 501 10222 ISS 212…-2E0-S12 ISS 212…-4E0-S12 2 mm 4 mm 6 mm 10 - 30 V DC 3 kHz embedded z Slim and very short cylindrical metal housing M12 z Chromium-plated brass housing z Built-in short circuit protection, inductive protection and polarity reversal protection z LED for switching state visible from 360° Tightening torque of the fastening nuts < 10Nm ! A B We reserve the right to make changes • 212_03gb.fm C UL Electrical connection US LISTED IEC 60947... IEC 60947... Active surface Yellow indicator diode Cable IP 67 Accessories: (available separately) z M12 connectors (KD … ) z Ready-made cables (K-D …) z Mounting clamp (MC 012…) M12 connector …NO… (normally open) …NO…-S12 (normally open): …NC…-S12 (normally closed): …NC… (normally closed) 3-pin or 4-pin M12 connection cables can be used. only 4-pin M12 connection cables can be used. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] ISS 212 Specifications General specifications Type of installation Typ. operating range limit Sn Operating range Sa Tables ISS 212…-2E0… ISS 212…-4E0… embedded installation 2.0mm 4.0mm 0 … 1.6mm 0 … 3.2mm ISS 212…-6E0… 6.0mm 0 … 4.8mm Electrical data Operating voltage UB 1) Residual ripple σ Output current IL Open-circuit current I0 Residual current Ir Switching output/function …/4NO… …/4NC… …/2NO… …/2NC… Voltage drop Ud Hysteresis H of Sr Temperature drift of Sr Repeatability 10 … 30VDC ≤ 20% of UB ≤ 200mA ≤ 10mA ≤ 100μA PNP transistor, make-contact (NO) PNP transistor, break-contact (NC) NPN transistor, make-contact (NO) NPN transistor, break-contact (NC) ≤ 2V ≤ 10% ≤ 15% ≤ 10% 2) ≤ 5% 3) ≤ 10% Reduction factors: for Sn = 2.0mm Steel Fe360 1 Copper 0.20 Aluminum 0.30 Brass 0.40 Stainless steel 0.85 for Sn = 6.0mm Steel Fe360 1 Copper 0.25 Aluminum 0.30 Brass 0.40 Stainless steel 0.70 for Sn = 4.0mm Steel Fe360 Copper Aluminum Brass Stainless steel 1 0.40 0.44 0.54 0.80 Mounting Embedded installation: Timing Switching frequency f Delay before start-up 3kHz ≤ 10ms 2kHz ≤ 300ms 800Hz ≤ 50ms ≥ 3Sn d Indicators Yellow LED (visible from 360°) switching state D2 d D3 D1 Mechanical data 18 x 18mm², Fe360 d Connection type chromium-plated brass 12 x 12mm², Fe360 12 x 12mm², Fe360 PBTP approx. 25g/ approx. 95g M12 connector 4-pin or cable: 2m, PVC, 3 x 0.34mm², Ø 5.0mm d Housing Standard surface plate Active surface Weight (M12 plug/cable) Environmental data Ambient temperature Protection class Protective circuit 4) Standards applied Electromagnetic compatibility -25°C … +70°C IP 67 1, 2, 3 IEC/EN 60947-5-2 IEC 60255-5 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 ≥ 3Sn 1kV Level 3 air 8kV (ESD) Level 3 10V/m (RFI) Level 3 2kV (Burst) 1) Observe the safety regulations and installation instructions regarding power supply and wiring; for UL applications: only for use in "Class 2" circuits acc. to NEC 2) Over the entire operating temperature range 3) For UB = 20 … 30VDC, ambient temperature Ta = 23°C ± 5°C 4) 1=polarity reversal protection, 2=short circuit protection, 3=inductive protection for all outputs Ferromagnetic and non-ferromagnetic materials Sn [mm] D1 [mm] D2 [mm] D3 [mm] 2.0 4.0 6.0 0 0 2.0 6.0 12.0 18.0 2.0 4.0 6.0 Order guide The sensors listed here are preferred types; current information at Leuze website. Designation Part No. Sn = 4mm ISS 212 MM/4NO-4E0 ISS 212 MM/4NO-4E0-S12 ISS 212 MM/4NC-4E0-S12 ISS 212 MM/2NO-4E0-S12 501 09684 501 09685 501 09676 501 09687 Sn = 6mm ISS 212 MM/4NO-6E0-S12 ISS 212 MM/2NO-6E0-S12 501 09679 501 09688 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] ISS 212 Inductive switches Diagrams Models with Sn = 2.0mm Models with Sn = 4.0mm Models with Sn = 6.0mm Inductive switch Inductive switch Inductive switch Standard surface plate Standard surface plate Standard surface plate Type key I S S 2 1 2 M M / 4 N O - 4 E 0 - S 1 2 Operating principle / construction ISS Inductive switch / short construction Series 212 series with M12 x 1 external thread Housing / thread MM metal housing (active surface: plastic) / metric thread Output function 4NO PNP transistor, make-contact (NO) 4NC PNP transistor, break-contact (NC) 2NO NPN transistor, make-contact (NO) 2NC NPN transistor, break-contact (NC) Measurement range / type of installation 2E0 typ. scan range limit 2.0mm / embedded installation 4E0 typ. scan range limit 4.0mm / embedded installation 6E0 typ. scan range limit 6.0mm / embedded installation Electrical connection N/A cable, PVC, standard length 2000mm S12 M12 connector, 4-pin, axial 200-S12 cable, PVC, length 200mm with M12 connector, 4-pin, axial Remarks z Approved purpose: Inductive switches are electronic sensors used for the inductive, contactless detection of objects. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] IS 212 Inductive switches Dimensioned drawing IS 212…-10N-S12 en 02-2010/03 50110219 IS 212…-4N0-S12 IS 212…-8N0-S12 4 mm 8 mm 10 mm 10 - 30 V DC 2 kHz non-embedded z Slim and short cylindrical metal housing M12 z Chromium-plated brass housing z Built-in short circuit protection, inductive protection and polarity reversal protection z LED for switching state visible from 360° Tightening torque of the fastening nuts < 10Nm ! We reserve the right to make changes • DS_IS_212_N_en.fm A B C UL Electrical connection US LISTED IEC 60947... IEC 60947... Active surface Yellow indicator diode Cable IP 67 Accessories: (available separately) z M12 connectors (KD … ) z Ready-made cables (K-D …) z Mounting clamp (MC 012…) M12 connector …NO… (normally open) …NO…-S12 (normally open): …NC…-S12 (normally closed): …NC… (normally closed) 3-pin or 4-pin M12 connection cables can be used. only 4-pin M12 connection cables can be used. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] IS 212 Specifications General specifications Type of installation Typ. operating range limit Sn Operating range Sa Tables IS 212…-4N0… IS 212…-8N0… IS 212…-10N… non-embedded installation 4.0mm 8.0mm 0 … 3.2mm 0 … 6.4mm 10.0mm 0 … 8.1mm 10 … 30VDC ≤ 20% of UB ≤ 200mA ≤ 10mA ≤ 100μA PNP transistor, make-contact (NO) PNP transistor, break-contact (NC) NPN transistor, make-contact (NO) NPN transistor, break-contact (NC) ≤ 2V ≤ 10% ≤ 10% 2) ≤ 5% 3) ≤ 5% 3) ≤ 3% 3) 2kHz ≤ 10ms 400Hz ≤ 50ms Electrical data Operating voltage UB 1) Residual ripple σ Output current IL Open-circuit current I0 Residual current Ir Switching output/function …/4NO… …/4NC… …/2NO… …/2NC… Voltage drop Ud Hysteresis H of Sr Temperature drift of Sr Repeatability Timing Switching frequency f Delay before start-up 1.5kHz ≤ 10ms Reduction factors: for Sn = 4.0mm Steel Fe360 1 Copper 0.50 Aluminum 0.50 Brass 0.60 Stainless steel 0.90 for Sn = 10.0mm Steel Fe360 1 Copper 0.41 Aluminum 0.46 Brass 0.52 Stainless steel 0.74 Non-embedded installation: ≥ 3Sn switching state d Mechanical data Housing Standard surface plate Active surface Weight (M12 plug/cable) Connection type 1 0.45 0.7 0.55 0.75 Mounting Indicators Yellow LED (visible from 360°) for Sn = 8.0mm Steel Fe360 Copper Aluminum Brass Stainless steel chromium-plated brass 12 x 12mm², Fe360 24 x 24mm², Fe360 30 x 30mm², Fe360 PBTP approx. 30g/ approx. 95g M12 connector 4-pin or cable: 2m, PVC, 3 x 0.34mm², Ø 5.0mm D2 d D3 D1 -25°C … +70°C IP 67 1, 2, 3 IEC/EN 60947-5-2 IEC 60255-5 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 d Ambient temperature Protection class Protective circuit 4) Standards applied Electromagnetic compatibility d Environmental data ≥ 3Sn 1kV Level 3 air 8kV (ESD) Level 3 10V/m (RFI) Level 3 2kV (Burst) 1kV Level 3 air 8kV (ESD) Level 3 10V/m (RFI) Level 3 2kV (Burst) 1) Observe the safety regulations and installation instructions regarding power supply and wiring; for UL applications: only for use in "Class 2" circuits acc. to NEC 2) Over the entire operating temperature range 3) For UB = 20 … 30VDC, ambient temperature Ta = 23°C ± 5°C 4) 1=polarity reversal protection, 2=short circuit protection, 3=inductive protection for all outputs Ferromagnetic and non-ferromagnetic materials Sn [mm] D1 [mm] D2 [mm] D3 [mm] 4.0 8.0 10.0 6.0 9.0 13.0 16.0 33.0 30.0 6.0 14.0 10.0 Order guide The sensors listed here are preferred types; current information at Leuze website. Designation Part No. Sn = 4mm IS 212 MM/4NO-4N0 IS 212 MM/4NO-4N0-S12 IS 212 MM/2NO-4N0 50109668 50109669 50109670 Sn = 8mm IS 212 MM/4NO-8N0 IS 212 MM/4NO-8N0-S12 50112807 50112808 Sn = 10mm IS 212 MM/4NO-10N IS 212 MM/2NO-10N 50109689 50111952 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] IS 212 Inductive switches Diagrams Models with Sn = 4.0mm Models with Sn = 8.0mm Models with Sn = 10.0mm Inductive switch Inductive switch Inductive switch Standard surface plate Standard surface plate Standard surface plate Type key I S 2 1 2 M M / 4 N O - 4 N 0 - S 1 2 Operating principle / construction IS Inductive switch / Standard Series 212 Series with M12 x 1 external thread Housing / thread MM Metal housing (active surface: plastic) / metric thread Output function 4NO PNP transistor, make-contact (NO) 4NC PNP transistor, break-contact (NC) 2NO NPN transistor, make-contact (NO) 2NC NPN transistor, break-contact (NC) Measurement range / type of installation 4N0 Typ. scan range limit 4.0mm / non-embedded installation 8N0 Typ. scan range limit 8.0mm / non-embedded installation 10N Typ. scan range limit 10.0mm / non-embedded installation Electrical connection N/A Cable, PVC, standard length 2000mm S12 M12 connector, 4-pin, axial 200-S12 Cable, PVC, length 200mm with M12 connector, 4-pin, axial Remarks z Approved purpose: The inductive switches are electronic sensors for the inductive, contactless detection of objects. This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]