Download Series IS212

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
IS 212
Inductive switches
Dimensioned drawing
IS 212…-2E0-S12
IS 212…-4E0-S12
en 02-2010/03 50110220
IS 212…-6E0-S12
2 mm
4 mm
6 mm
10 - 30 V
DC
3 kHz
Embedded
z Slim and short cylindrical metal housing
M12
z Chromium-plated brass housing
z Built-in short circuit protection, inductive
protection and polarity reversal protection
z LED for switching state visible from 360°
Tightening torque of the fastening nuts < 10Nm !
We reserve the right to make changes • DS_IS_212_E_en.fm
A
B
C
UL
Electrical connection
US
LISTED
IEC 60947...
IEC 60947...
Active surface
Yellow indicator diode
Cable
IP 67
Accessories:
(available separately)
z M12 connectors (KD … )
z Ready-made cables (K-D …)
z Mounting clamp (MC 012…)
M12 connector
…NO… (normally open)
…NO…-S12 (normally open):
…NC…-S12 (normally closed):
…NC… (normally closed)
3-pin or 4-pin M12 connection cables can be used.
only 4-pin M12 connection cables can be used.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
IS 212
Specifications
General specifications
Type of installation
Typ. operating range limit Sn
Operating range Sa
Tables
IS 212…-2E0…
IS 212…-4E0…
embedded installation
2.0mm
4.0mm
0 … 1.6mm
0 … 3.2mm
IS 212…-6E0…
6.0mm
0 … 4.8mm
Electrical data
Operating voltage UB 1)
Residual ripple σ
Output current IL
Open-circuit current I0
Residual current Ir
Switching output/function …/4NO…
…/4NC…
…/2NO…
…/2NC…
Voltage drop Ud
Hysteresis H of Sr
Temperature drift of Sr
Repeatability
10 … 30VDC
≤ 20% of UB
≤ 200mA
≤ 10mA
≤ 100μA
PNP transistor, make-contact (NO)
PNP transistor, break-contact (NC)
NPN transistor, make-contact (NO)
NPN transistor, break-contact (NC)
≤ 2V
≤ 10%
≤ 15%
≤ 10% 2)
≤ 5% 3)
≤ 10%
Reduction factors:
for Sn = 2.0mm
Steel Fe360
1
Copper
0.20
Aluminum
0.30
Brass
0.40
Stainless steel
0.85
for Sn = 6.0mm
Steel Fe360
1
Copper
0.25
Aluminum
0.30
Brass
0.40
Stainless steel
0.70
for Sn = 4.0mm
Steel Fe360
Copper
Aluminum
Brass
Stainless steel
1
0.40
0.44
0.54
0.80
Mounting
Embedded installation:
Timing
3kHz
≤ 10ms
2kHz
≤ 300ms
800Hz
≤ 50ms
≥ 3Sn
Indicators
d
switching state
Mechanical data
Housing
Standard surface plate
Active surface
Weight (M12 plug/cable)
Connection type
chromium-plated
brass
12 x 12mm², Fe360 12 x 12mm², Fe360
PBTP
approx. 25g/
approx. 95g
M12 connector 4-pin or
cable: 2m, PVC, 3 x 0.34mm², Ø 5.0mm
-25°C … +70°C
IP 67
1, 2, 3
IEC/EN 60947-5-2
IEC 60255-5
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
d
D3
18 x 18mm², Fe360
Environmental data
Ambient temperature
Protection class
Protective circuit 4)
Standards applied
Electromagnetic compatibility
D2
D1
d
Yellow LED (visible from 360°)
d
Switching frequency f
Delay before start-up
≥ 3Sn
1kV
Level 3 air 8kV (ESD)
Level 3 10V/m (RFI)
Level 3 2kV (Burst)
Ferromagnetic and
non-ferromagnetic materials
Sn [mm] D1 [mm] D2 [mm] D3 [mm]
2.0
4.0
6.0
0
0
2.0
6.0
12.0
18.0
2.0
4.0
6.0
1) Observe the safety regulations and installation instructions regarding power supply and wiring;
for UL applications: only for use in "Class 2" circuits acc. to NEC
2) Over the entire operating temperature range
3) For UB = 20 … 30VDC, ambient temperature Ta = 23°C ± 5°C
4) 1=polarity reversal protection, 2=short circuit protection, 3=inductive protection for all outputs
Order guide
The sensors listed here are preferred types; current information at Leuze website.
Designation
Part No.
Sn = 2mm
IS 212 MM/4NO-2E0
IS 212 MM/4NO-2E0-S12
IS 212 MM/4NC-2E0-S12
IS 212 MM/2NO-2E0
50109664
50109665
50111870
50109666
Sn = 4mm
IS 212 MM/4NO-4E0
IS 212 MM/4NO-4E0-S12
IS 212 MM/4NC-4E0-S12
IS 212 MM/2NO-4E0
50109672
50109673
50109674
50109675
Sn = 6mm
IS 212 MM/4NO-6E0
IS 212 MM/2NO-6E0
50109678
50109682
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
IS 212
Inductive switches
Diagrams
Models with Sn = 2.0mm
Models with Sn = 4.0mm
Models with Sn = 6.0mm
Inductive switch
Inductive switch
Inductive switch
Standard surface plate
Standard surface plate
Standard surface plate
Type key
I S
2 1 2
M M / 4 N O - 4 E 0 - S 1 2
Operating principle / construction
IS
Inductive switch / Standard
Series
212
Series with M12 x 1 external thread
Housing / thread
MM
Metal housing (active surface: plastic) / metric thread
Output function
4NO
PNP transistor, make-contact (NO)
4NC
PNP transistor, break-contact (NC)
2NO
NPN transistor, make-contact (NO)
2NC
NPN transistor, break-contact (NC)
Measurement range / type of installation
2E0
Typ. scan range limit 2.0mm / embedded installation
4E0
Typ. scan range limit 4.0mm / embedded installation
6E0
Typ. scan range limit 6.0mm / embedded installation
Electrical connection
N/A
Cable, PVC, standard length 2000mm
S12
M12 connector, 4-pin, axial
200-S12
Cable, PVC, length 200mm with M12 connector, 4-pin, axial
Remarks
z Approved purpose:
The inductive switches are electronic sensors for the inductive, contactless detection of objects.
This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a
safety sensor and is not to be used for the protection of persons.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
ISS 212
Inductive switches
Dimensioned drawing
ISS 212…-10N-S12
Part No. 501 10221
ISS 212…-4N0-S12
4 mm
10 mm
10 - 30 V
DC
400 Hz
non-embedded
z Slim and very short cylindrical metal housing M12
z Chromium-plated brass housing
z Built-in short circuit protection, inductive
protection and polarity reversal protection
z LED for switching state visible from 360°
Tightening torque of the fastening nuts < 10Nm !
A
B
We reserve the right to make changes • 212_04gb.fm
C
UL
Electrical connection
US
LISTED
IEC 60947...
IEC 60947...
Active surface
Yellow indicator diode
Cable
IP 67
Accessories:
(available separately)
z M12 connectors (KD … )
z Ready-made cables (K-D …)
z Mounting clamp (MC 012…)
M12 connector
…NO… (normally open)
…NO…-S12 (normally open):
…NC…-S12 (normally closed):
…NC… (normally closed)
3-pin or 4-pin M12 connection cables can be used.
only 4-pin M12 connection cables can be used.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
ISS 212
Specifications
Tables
General specifications
Type of installation
Typ. operating range limit Sn
Operating range Sa
ISS 212…-4N0…
ISS 212…-10N…
non-embedded installation
4.0mm
0 … 3.2mm
10.0mm
0 … 8.1mm
Electrical data
Operating voltage UB 1)
Residual ripple σ
Output current IL
Open-circuit current I0
Residual current Ir
Switching output/function
Voltage drop Ud
Hysteresis H of Sr
Temperature drift of Sr
Repeatability
…/4NO…
…/4NC…
…/2NO…
…/2NC…
10 … 30VDC
≤ 20% of UB
≤ 200mA
≤ 10mA
≤ 100μA
PNP transistor, make-contact (NO)
PNP transistor, break-contact (NC)
NPN transistor, make-contact (NO)
NPN transistor, break-contact (NC)
≤ 2V
≤ 10%
≤ 10% 2)
≤ 5% 3)
≤ 3% 3)
Timing
Switching frequency f
Delay before start-up
2kHz
≤ 10ms
Reduction factors:
for Sn = 4.0mm
Steel Fe360
1
Copper
0.50
Aluminum
0.50
Brass
0.60
Stainless steel
0.90
for Sn = 10.0mm
Steel Fe360
1
Copper
0.41
Aluminum
0.46
Brass
0.52
Stainless steel
0.74
Mounting
Non-embedded installation:
≥ 3Sn
d
D2
d
D3
D1
400Hz
≤ 50ms
Indicators
Yellow LED (visible from 360°)
switching state
chromium-plated brass
12 x 12mm², Fe360
30 x 30mm², Fe360
PBTP
approx. 30g/approx. 95g
M12 connector 4-pin or
cable: 2m, PVC, 3 x 0.34mm², Ø 5.0mm
Environmental data
Ambient temperature
Protection class
Protective circuit 4)
Standards applied
Electromagnetic compatibility
-25°C … +70°C
IP 67
1, 2, 3
IEC/EN 60947-5-2
IEC 60255-5
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
≥ 3Sn
Ferromagnetic and non-ferromagnetic
materials
Sn [mm] D1 [mm] D2 [mm] D3 [mm]
4.0
10.0
1kV
Level 3 air 8kV (ESD)
Level 3 10V/m (RFI)
Level 3 2kV (Burst)
d
Housing
Standard surface plate
Active surface
Weight (M12 plug/cable)
Connection type
d
Mechanical data
6.0
10.0
16.0
30.0
6.0
10.0
Diagrams
Models with Sn = 4.0mm
1) Observe the safety regulations and installation instructions regarding power supply and wiring;
for UL applications: only for use in "Class 2" circuits acc. to NEC
2) Over the entire operating temperature range
3) For UB = 20 … 30VDC, ambient temperature Ta = 23°C ± 5°C
4) 1=polarity reversal protection, 2=short circuit protection, 3=inductive protection for all outputs
Order guide
Inductive switch
The sensors listed here are preferred types; current information at leuze website.
Sn = 10mm
Designation
Part No.
ISS 212 MM/4NO-10N-S12
501 09680
Standard surface plate
Models with Sn = 10.0mm
Inductive switch
Standard surface plate
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
ISS 212
Inductive switches
Type key
I S S
2 1 2
M M / 4 N O - 1 0 N - S 1 2
Operating principle / construction
ISS
Inductive switch / short construction
Series
212
series with M12 x 1 external thread
Housing / thread
MM
metal housing (active surface: plastic) / metric thread
Output function
4NO
PNP transistor, make-contact (NO)
4NC
PNP transistor, break-contact (NC)
2NO
NPN transistor, make-contact (NO)
2NC
NPN transistor, break-contact (NC)
Measurement range / type of installation
4N0
typ. scan range limit 4.0mm / non-embedded installation
10N
typ. scan range limit 10.0mm / non-embedded installation
Electrical connection
N/A
cable, PVC, standard length 2000mm
S12
M12 connector, 4-pin, axial
200-S12
cable, PVC, length 200mm with M12 connector, 4-pin, axial
Remarks
z Approved purpose:
Inductive switches are electronic sensors used for the inductive, contactless detection of objects.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
ISS 212
Inductive switches
Dimensioned drawing
ISS 212…-6E0-S12
Part No. 501 10222
ISS 212…-2E0-S12
ISS 212…-4E0-S12
2 mm
4 mm
6 mm
10 - 30 V
DC
3 kHz
embedded
z Slim and very short cylindrical metal housing M12
z Chromium-plated brass housing
z Built-in short circuit protection, inductive
protection and polarity reversal protection
z LED for switching state visible from 360°
Tightening torque of the fastening nuts < 10Nm !
A
B
We reserve the right to make changes • 212_03gb.fm
C
UL
Electrical connection
US
LISTED
IEC 60947...
IEC 60947...
Active surface
Yellow indicator diode
Cable
IP 67
Accessories:
(available separately)
z M12 connectors (KD … )
z Ready-made cables (K-D …)
z Mounting clamp (MC 012…)
M12 connector
…NO… (normally open)
…NO…-S12 (normally open):
…NC…-S12 (normally closed):
…NC… (normally closed)
3-pin or 4-pin M12 connection cables can be used.
only 4-pin M12 connection cables can be used.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
ISS 212
Specifications
General specifications
Type of installation
Typ. operating range limit Sn
Operating range Sa
Tables
ISS 212…-2E0…
ISS 212…-4E0…
embedded installation
2.0mm
4.0mm
0 … 1.6mm
0 … 3.2mm
ISS 212…-6E0…
6.0mm
0 … 4.8mm
Electrical data
Operating voltage UB 1)
Residual ripple σ
Output current IL
Open-circuit current I0
Residual current Ir
Switching output/function …/4NO…
…/4NC…
…/2NO…
…/2NC…
Voltage drop Ud
Hysteresis H of Sr
Temperature drift of Sr
Repeatability
10 … 30VDC
≤ 20% of UB
≤ 200mA
≤ 10mA
≤ 100μA
PNP transistor, make-contact (NO)
PNP transistor, break-contact (NC)
NPN transistor, make-contact (NO)
NPN transistor, break-contact (NC)
≤ 2V
≤ 10%
≤ 15%
≤ 10% 2)
≤ 5% 3)
≤ 10%
Reduction factors:
for Sn = 2.0mm
Steel Fe360
1
Copper
0.20
Aluminum
0.30
Brass
0.40
Stainless steel
0.85
for Sn = 6.0mm
Steel Fe360
1
Copper
0.25
Aluminum
0.30
Brass
0.40
Stainless steel
0.70
for Sn = 4.0mm
Steel Fe360
Copper
Aluminum
Brass
Stainless steel
1
0.40
0.44
0.54
0.80
Mounting
Embedded installation:
Timing
Switching frequency f
Delay before start-up
3kHz
≤ 10ms
2kHz
≤ 300ms
800Hz
≤ 50ms
≥ 3Sn
d
Indicators
Yellow LED (visible from 360°)
switching state
D2
d
D3
D1
Mechanical data
18 x 18mm², Fe360
d
Connection type
chromium-plated brass
12 x 12mm², Fe360 12 x 12mm², Fe360
PBTP
approx. 25g/
approx. 95g
M12 connector 4-pin or
cable: 2m, PVC, 3 x 0.34mm², Ø 5.0mm
d
Housing
Standard surface plate
Active surface
Weight (M12 plug/cable)
Environmental data
Ambient temperature
Protection class
Protective circuit 4)
Standards applied
Electromagnetic compatibility
-25°C … +70°C
IP 67
1, 2, 3
IEC/EN 60947-5-2
IEC 60255-5
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
≥ 3Sn
1kV
Level 3 air 8kV (ESD)
Level 3 10V/m (RFI)
Level 3 2kV (Burst)
1) Observe the safety regulations and installation instructions regarding power supply and wiring;
for UL applications: only for use in "Class 2" circuits acc. to NEC
2) Over the entire operating temperature range
3) For UB = 20 … 30VDC, ambient temperature Ta = 23°C ± 5°C
4) 1=polarity reversal protection, 2=short circuit protection, 3=inductive protection for all outputs
Ferromagnetic and non-ferromagnetic
materials
Sn [mm] D1 [mm] D2 [mm] D3 [mm]
2.0
4.0
6.0
0
0
2.0
6.0
12.0
18.0
2.0
4.0
6.0
Order guide
The sensors listed here are preferred types; current information at Leuze website.
Designation
Part No.
Sn = 4mm
ISS 212 MM/4NO-4E0
ISS 212 MM/4NO-4E0-S12
ISS 212 MM/4NC-4E0-S12
ISS 212 MM/2NO-4E0-S12
501 09684
501 09685
501 09676
501 09687
Sn = 6mm
ISS 212 MM/4NO-6E0-S12
ISS 212 MM/2NO-6E0-S12
501 09679
501 09688
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
ISS 212
Inductive switches
Diagrams
Models with Sn = 2.0mm
Models with Sn = 4.0mm
Models with Sn = 6.0mm
Inductive switch
Inductive switch
Inductive switch
Standard surface plate
Standard surface plate
Standard surface plate
Type key
I S S
2 1 2
M M / 4 N O - 4 E 0 - S 1 2
Operating principle / construction
ISS
Inductive switch / short construction
Series
212
series with M12 x 1 external thread
Housing / thread
MM
metal housing (active surface: plastic) / metric thread
Output function
4NO
PNP transistor, make-contact (NO)
4NC
PNP transistor, break-contact (NC)
2NO
NPN transistor, make-contact (NO)
2NC
NPN transistor, break-contact (NC)
Measurement range / type of installation
2E0
typ. scan range limit 2.0mm / embedded installation
4E0
typ. scan range limit 4.0mm / embedded installation
6E0
typ. scan range limit 6.0mm / embedded installation
Electrical connection
N/A
cable, PVC, standard length 2000mm
S12
M12 connector, 4-pin, axial
200-S12
cable, PVC, length 200mm with M12 connector, 4-pin, axial
Remarks
z Approved purpose:
Inductive switches are electronic sensors used for the inductive, contactless detection of objects.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
IS 212
Inductive switches
Dimensioned drawing
IS 212…-10N-S12
en 02-2010/03 50110219
IS 212…-4N0-S12
IS 212…-8N0-S12
4 mm
8 mm
10 mm
10 - 30 V
DC
2 kHz
non-embedded
z Slim and short cylindrical metal housing
M12
z Chromium-plated brass housing
z Built-in short circuit protection, inductive
protection and polarity reversal protection
z LED for switching state visible from 360°
Tightening torque of the fastening nuts < 10Nm !
We reserve the right to make changes • DS_IS_212_N_en.fm
A
B
C
UL
Electrical connection
US
LISTED
IEC 60947...
IEC 60947...
Active surface
Yellow indicator diode
Cable
IP 67
Accessories:
(available separately)
z M12 connectors (KD … )
z Ready-made cables (K-D …)
z Mounting clamp (MC 012…)
M12 connector
…NO… (normally open)
…NO…-S12 (normally open):
…NC…-S12 (normally closed):
…NC… (normally closed)
3-pin or 4-pin M12 connection cables can be used.
only 4-pin M12 connection cables can be used.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
IS 212
Specifications
General specifications
Type of installation
Typ. operating range limit Sn
Operating range Sa
Tables
IS 212…-4N0…
IS 212…-8N0…
IS 212…-10N…
non-embedded installation
4.0mm
8.0mm
0 … 3.2mm
0 … 6.4mm
10.0mm
0 … 8.1mm
10 … 30VDC
≤ 20% of UB
≤ 200mA
≤ 10mA
≤ 100μA
PNP transistor, make-contact (NO)
PNP transistor, break-contact (NC)
NPN transistor, make-contact (NO)
NPN transistor, break-contact (NC)
≤ 2V
≤ 10%
≤ 10% 2)
≤ 5% 3)
≤ 5% 3)
≤ 3% 3)
2kHz
≤ 10ms
400Hz
≤ 50ms
Electrical data
Operating voltage UB 1)
Residual ripple σ
Output current IL
Open-circuit current I0
Residual current Ir
Switching output/function …/4NO…
…/4NC…
…/2NO…
…/2NC…
Voltage drop Ud
Hysteresis H of Sr
Temperature drift of Sr
Repeatability
Timing
Switching frequency f
Delay before start-up
1.5kHz
≤ 10ms
Reduction factors:
for Sn = 4.0mm
Steel Fe360
1
Copper
0.50
Aluminum
0.50
Brass
0.60
Stainless steel
0.90
for Sn = 10.0mm
Steel Fe360
1
Copper
0.41
Aluminum
0.46
Brass
0.52
Stainless steel
0.74
Non-embedded
installation:
≥ 3Sn
switching state
d
Mechanical data
Housing
Standard surface plate
Active surface
Weight (M12 plug/cable)
Connection type
1
0.45
0.7
0.55
0.75
Mounting
Indicators
Yellow LED (visible from 360°)
for Sn = 8.0mm
Steel Fe360
Copper
Aluminum
Brass
Stainless steel
chromium-plated
brass
12 x 12mm², Fe360 24 x 24mm², Fe360 30 x 30mm², Fe360
PBTP
approx. 30g/
approx. 95g
M12 connector 4-pin or
cable: 2m, PVC, 3 x 0.34mm², Ø 5.0mm
D2
d
D3
D1
-25°C … +70°C
IP 67
1, 2, 3
IEC/EN 60947-5-2
IEC 60255-5
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
d
Ambient temperature
Protection class
Protective circuit 4)
Standards applied
Electromagnetic compatibility
d
Environmental data
≥ 3Sn
1kV
Level 3 air 8kV (ESD)
Level 3 10V/m (RFI)
Level 3 2kV (Burst)
1kV
Level 3 air 8kV (ESD)
Level 3 10V/m (RFI)
Level 3 2kV (Burst)
1) Observe the safety regulations and installation instructions regarding power supply and wiring;
for UL applications: only for use in "Class 2" circuits acc. to NEC
2) Over the entire operating temperature range
3) For UB = 20 … 30VDC, ambient temperature Ta = 23°C ± 5°C
4) 1=polarity reversal protection, 2=short circuit protection, 3=inductive protection for all outputs
Ferromagnetic and
non-ferromagnetic materials
Sn [mm] D1 [mm] D2 [mm] D3 [mm]
4.0
8.0
10.0
6.0
9.0
13.0
16.0
33.0
30.0
6.0
14.0
10.0
Order guide
The sensors listed here are preferred types; current information at Leuze website.
Designation
Part No.
Sn = 4mm
IS 212 MM/4NO-4N0
IS 212 MM/4NO-4N0-S12
IS 212 MM/2NO-4N0
50109668
50109669
50109670
Sn = 8mm
IS 212 MM/4NO-8N0
IS 212 MM/4NO-8N0-S12
50112807
50112808
Sn = 10mm
IS 212 MM/4NO-10N
IS 212 MM/2NO-10N
50109689
50111952
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
IS 212
Inductive switches
Diagrams
Models with Sn = 4.0mm
Models with Sn = 8.0mm
Models with Sn = 10.0mm
Inductive switch
Inductive switch
Inductive switch
Standard surface plate
Standard surface plate
Standard surface plate
Type key
I S
2 1 2
M M / 4 N O - 4 N 0 - S 1 2
Operating principle / construction
IS
Inductive switch / Standard
Series
212
Series with M12 x 1 external thread
Housing / thread
MM
Metal housing (active surface: plastic) / metric thread
Output function
4NO
PNP transistor, make-contact (NO)
4NC
PNP transistor, break-contact (NC)
2NO
NPN transistor, make-contact (NO)
2NC
NPN transistor, break-contact (NC)
Measurement range / type of installation
4N0
Typ. scan range limit 4.0mm / non-embedded installation
8N0
Typ. scan range limit 8.0mm / non-embedded installation
10N
Typ. scan range limit 10.0mm / non-embedded installation
Electrical connection
N/A
Cable, PVC, standard length 2000mm
S12
M12 connector, 4-pin, axial
200-S12
Cable, PVC, length 200mm with M12 connector, 4-pin, axial
Remarks
z Approved purpose:
The inductive switches are electronic sensors for the inductive, contactless detection of objects.
This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a
safety sensor and is not to be used for the protection of persons.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
Related documents