Download Power Feed Equipment - Spellman High Voltage Electronics

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Variable-frequency drive wikipedia , lookup

Transcript
PFE
LOW VOLTAGE POWER
FEED EQUIPMENT
SPELLMAN HIGH VOLTAGE ELECTRONICS CORPORATION
PAGE 1 OF 2
• FULL ARRAY OF DRY CONTACT CLOSURES AVAILABLE
FOR REMOTE STATION ALARM MONITORING
• FULLY-PROGRAMMABLE ELECTRONIC TEST LOAD
CAPABLE OF DISSIPATING 5KW
• ELECTRODING FUNCTIONS PROVIDED
• SINGLE CABINET. REAR DOOR PROVIDED FOR
SAFETY INTERLOCKING
Spellman High Voltage Electronics, the leading independent supplier of Power Feed Equipment to the Telecom
industry, has developed a new generation of Low Voltage
Power Feed Equipment, (LVPFE). This proposed new
LVPFE is targeted at the emerging requirements for shorter
submarine cable installations, while addressing underlying
markets issues such as lower cost, smaller foot print, and
easier operation.
Output Power:
5kW for 1+1 redundancy
KEY FEATURES
Redundancy is provided for the converters (1+1)
Simplified sliding drawers for PFE open, grounding,
test modes
Redundancy is provided for the LCU. In case of
failure of LCU, the PFE will continue to operate
normally
LCU contains pull-out 17˝ LCD screen,
keyboard, trackball and CPU
Simplified keylock scheme ensures safety of
operating personnel
Highly visible Vacuum Fluorescent Display (VFD) on
each Converter displays voltage, current and modes
of operation
Unique protective “trap door” barrier allows a converter or test load to be replaced safely while the PFE is
still powering the cable
Current Ripple:
10mA peak to peak of maximum output
Input Voltage:
-40.5 VDC to -60 VDC
Programming:
Full-featured programming, monitoring, alarms, diagnostics,
and ramping functions provided via LCU module.
Monitoring:
Full local and remote monitoring via Ethernet connection.
Voltage Ripple:
0.2% peak to peak of maximum output
Current Stability:
0.1% (constant load) after a 4 hour warm up
Operating Temperature:
5 to 40°C operating
Storage Temperature:
-40 to +85°C storage
Humidity:
5% to 85%, non-condensing
Cooling:
Forced Air
Dimensions:
86.68”H x 23.64”W x 23.64”D
(2200mm x 600mm x 600mm)
Weight:
900 pounds (335.9kg)
SPECIFICATIONS
Output Voltage:
6kV maximum rated continuous operation, 5kV nominal
Output Current:
1.2A maximum rated continuous operation, 1.0A nominal
Regulatory Approvals:
Compliant to 2004/108/EC, The EMC Directive and
2006/95/EC, The Low Voltage Directive. Also complies
with: GR-63-CORE, GR-189-CORE, ETSI ETS 300 019,
ETS 300 118, ETS 300 127, ETSI EN 300 132-2,
ETSI EN 300 386, EN 60950.
Corporate Headquarters
Hauppauge, New York USA
+1-631-630-3000 FAX: +1-631-435-1620
e-mail: [email protected]
For locations worldwide
www.spellmanhv.com
PFE
REV. D
Spellman High Voltage is an ISO 9001:2008 and ISO 14001:2004 registered company
PFE
LOW VOLTAGE POWER
FEED EQUIPMENT
SPELLMAN HIGH VOLTAGE ELECTRONICS CORPORATION
PAGE 2 OF 2
DIMENSIONS: in.[mm]
FRONT VIEW
BACK VIEW
23.64 [600]
!
! CAUTION
2 PERSON HANDLING
REQUIRED
! CAUTION
UNHIT WEIGHS
36KG
! WARNING
TEST LOAD
FAN FILTER MUST BE
IN PLACE FOR PROPER
AND SAFE OPERATION
OF PFE
POWER ON
TEST LOAD
ACTIVE
TEST LOAD
FAULT
TEST LOAD
! WARNING
FAN FILTER MUST BE
IN PLACE FOR PROPER
AND SAFE OPERATION
OF PFE
2500 V
1000 mA
NORMAL
I-MODE
EMERGENCY STOP
CONVERTER
-
ALARM CUTOFF
+
1V = 1kV
VOLTAGE
-
ACO ACTIVE
+
HV ACTIVE
1V = 1A
CURRENT
MINOR ALARM
MAJOR ALARM
IN SERVICE
OUT OF SERVICE
! CAUTION
2 PERSON HANDLING
REQUIRED
!
! CAUTION
UNHIT WEIGHS
36KG
CONVERTER
! WARNING
FAN FILTER MUST BE
IN PLACE FOR PROPER
AND SAFE OPERATION
OF PFE
2500 V
1000 mA
NORMAL
I-MODE
EMERGENCY STOP
CONVERTER
-
VOLTAGE
-
ALARM CUTOFF
+
1V = 1kV
+
1V = 1A
ACO ACTIVE
HV ACTIVE
CURRENT
MINOR ALARM
MAJOR ALARM
IN SERVICE
! CAUTION
OUT OF SERVICE
! DANGER
2 PERSON HANDLING
REQUIRED
!
! CAUTION
UNHIT WEIGHS
36KG
CONVERTER
1
LOCAL
CONTROL
UNIT
2
3
4
5
6
7
8
HIGH
VOLTAGE
86.68 [2200]
ACCESS WARNING
9
POWER
GRID
OPENING DOOR WILL SHUT DOWN PFE
2
!
-
+
1V = 1kV
VOLTAGE
-
+
-
+
-
+
1V = 1A
PFE OUTPUT
1V = 1A
! CAUTION
POSITIVE
CURRENT
STATION
GROUND
CURRENT
1V = 1kV
POWER
OCEAN
GROUND
VOLTAGE
POLARITY
NEGATIVE
NORMAL
TEST
PFE
OUTPUT
STATUS
2 PERSON HANDLING
REQUIRED
! CAUTION
UNHIT WEIGHS
36KG
BYPASS
MVPFE CABINET
REV
S/N
M#
1
OCEAN
GROUND
NORMAL
CONVERTERS (MAIN)
HV
STATION
GROUND
CABLE
SHORT
1
IOU
CONVERTERS (AUX)
1
2
OG
TEST
JACK
A
TEST LOAD
B
A
B
2
PFF OUTPUT
A
B
BATTERY
VOLTAGE
+
-
+
-
A
B
!
EMPTY MODULE
(USED AS INTERLOCK
ALLOW SAFE REMOVAL
OF PFE OUTPUT)
Corporate Headquarters
Hauppauge, New York USA
+1-631-630-3000 FAX: +1-631-435-1620
e-mail: [email protected]
For locations worldwide
www.spellmanhv.com
PFE
REV. D
Spellman High Voltage is an ISO 9001:2008 and ISO 14001:2004 registered company