Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
PFE LOW VOLTAGE POWER FEED EQUIPMENT SPELLMAN HIGH VOLTAGE ELECTRONICS CORPORATION PAGE 1 OF 2 • FULL ARRAY OF DRY CONTACT CLOSURES AVAILABLE FOR REMOTE STATION ALARM MONITORING • FULLY-PROGRAMMABLE ELECTRONIC TEST LOAD CAPABLE OF DISSIPATING 5KW • ELECTRODING FUNCTIONS PROVIDED • SINGLE CABINET. REAR DOOR PROVIDED FOR SAFETY INTERLOCKING Spellman High Voltage Electronics, the leading independent supplier of Power Feed Equipment to the Telecom industry, has developed a new generation of Low Voltage Power Feed Equipment, (LVPFE). This proposed new LVPFE is targeted at the emerging requirements for shorter submarine cable installations, while addressing underlying markets issues such as lower cost, smaller foot print, and easier operation. Output Power: 5kW for 1+1 redundancy KEY FEATURES Redundancy is provided for the converters (1+1) Simplified sliding drawers for PFE open, grounding, test modes Redundancy is provided for the LCU. In case of failure of LCU, the PFE will continue to operate normally LCU contains pull-out 17˝ LCD screen, keyboard, trackball and CPU Simplified keylock scheme ensures safety of operating personnel Highly visible Vacuum Fluorescent Display (VFD) on each Converter displays voltage, current and modes of operation Unique protective “trap door” barrier allows a converter or test load to be replaced safely while the PFE is still powering the cable Current Ripple: 10mA peak to peak of maximum output Input Voltage: -40.5 VDC to -60 VDC Programming: Full-featured programming, monitoring, alarms, diagnostics, and ramping functions provided via LCU module. Monitoring: Full local and remote monitoring via Ethernet connection. Voltage Ripple: 0.2% peak to peak of maximum output Current Stability: 0.1% (constant load) after a 4 hour warm up Operating Temperature: 5 to 40°C operating Storage Temperature: -40 to +85°C storage Humidity: 5% to 85%, non-condensing Cooling: Forced Air Dimensions: 86.68”H x 23.64”W x 23.64”D (2200mm x 600mm x 600mm) Weight: 900 pounds (335.9kg) SPECIFICATIONS Output Voltage: 6kV maximum rated continuous operation, 5kV nominal Output Current: 1.2A maximum rated continuous operation, 1.0A nominal Regulatory Approvals: Compliant to 2004/108/EC, The EMC Directive and 2006/95/EC, The Low Voltage Directive. Also complies with: GR-63-CORE, GR-189-CORE, ETSI ETS 300 019, ETS 300 118, ETS 300 127, ETSI EN 300 132-2, ETSI EN 300 386, EN 60950. Corporate Headquarters Hauppauge, New York USA +1-631-630-3000 FAX: +1-631-435-1620 e-mail: [email protected] For locations worldwide www.spellmanhv.com PFE REV. D Spellman High Voltage is an ISO 9001:2008 and ISO 14001:2004 registered company PFE LOW VOLTAGE POWER FEED EQUIPMENT SPELLMAN HIGH VOLTAGE ELECTRONICS CORPORATION PAGE 2 OF 2 DIMENSIONS: in.[mm] FRONT VIEW BACK VIEW 23.64 [600] ! ! CAUTION 2 PERSON HANDLING REQUIRED ! CAUTION UNHIT WEIGHS 36KG ! WARNING TEST LOAD FAN FILTER MUST BE IN PLACE FOR PROPER AND SAFE OPERATION OF PFE POWER ON TEST LOAD ACTIVE TEST LOAD FAULT TEST LOAD ! WARNING FAN FILTER MUST BE IN PLACE FOR PROPER AND SAFE OPERATION OF PFE 2500 V 1000 mA NORMAL I-MODE EMERGENCY STOP CONVERTER - ALARM CUTOFF + 1V = 1kV VOLTAGE - ACO ACTIVE + HV ACTIVE 1V = 1A CURRENT MINOR ALARM MAJOR ALARM IN SERVICE OUT OF SERVICE ! CAUTION 2 PERSON HANDLING REQUIRED ! ! CAUTION UNHIT WEIGHS 36KG CONVERTER ! WARNING FAN FILTER MUST BE IN PLACE FOR PROPER AND SAFE OPERATION OF PFE 2500 V 1000 mA NORMAL I-MODE EMERGENCY STOP CONVERTER - VOLTAGE - ALARM CUTOFF + 1V = 1kV + 1V = 1A ACO ACTIVE HV ACTIVE CURRENT MINOR ALARM MAJOR ALARM IN SERVICE ! CAUTION OUT OF SERVICE ! DANGER 2 PERSON HANDLING REQUIRED ! ! CAUTION UNHIT WEIGHS 36KG CONVERTER 1 LOCAL CONTROL UNIT 2 3 4 5 6 7 8 HIGH VOLTAGE 86.68 [2200] ACCESS WARNING 9 POWER GRID OPENING DOOR WILL SHUT DOWN PFE 2 ! - + 1V = 1kV VOLTAGE - + - + - + 1V = 1A PFE OUTPUT 1V = 1A ! CAUTION POSITIVE CURRENT STATION GROUND CURRENT 1V = 1kV POWER OCEAN GROUND VOLTAGE POLARITY NEGATIVE NORMAL TEST PFE OUTPUT STATUS 2 PERSON HANDLING REQUIRED ! CAUTION UNHIT WEIGHS 36KG BYPASS MVPFE CABINET REV S/N M# 1 OCEAN GROUND NORMAL CONVERTERS (MAIN) HV STATION GROUND CABLE SHORT 1 IOU CONVERTERS (AUX) 1 2 OG TEST JACK A TEST LOAD B A B 2 PFF OUTPUT A B BATTERY VOLTAGE + - + - A B ! EMPTY MODULE (USED AS INTERLOCK ALLOW SAFE REMOVAL OF PFE OUTPUT) Corporate Headquarters Hauppauge, New York USA +1-631-630-3000 FAX: +1-631-435-1620 e-mail: [email protected] For locations worldwide www.spellmanhv.com PFE REV. D Spellman High Voltage is an ISO 9001:2008 and ISO 14001:2004 registered company