Power inverter wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Mains electricity wikipedia , lookup
Buck converter wikipedia , lookup
Public address system wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Pulse-width modulation wikipedia , lookup
• • • • MiniDim3/4 3/4 Channel DMX or Stand Alone LED Dimmer DMX-512 or Trim Potentiometer Adjustable Selectable Pulse Width Modulation Frequency Liquid-Tungsten© Brightness Slewing The MiniDim3 or 4 has a total system capacity of 5 amps – this capacity can be used any way you wish across the outputs, as long as you don't exceed the total available 5 amps. The controlled output to the LEDs is via an output screw barrier strip -RGB or RGBW (+) (-) labeled. The DC input is via a standard "Barrel" connector (2.1mm center pin) or a 2 conductor screw barrier strip - your choice, and DMX is using RJ45’s or 3 conductor screw barrier strip - your choice again. Reset to Factory Default modes: DMX address: 999 then press the learn switch LED Power: Externally supplied, 8-24 Volts DC. Transient voltage suppression engages at 25 volts. Leds must include current limiting resistors or constant current circuitry. ***NOTE: LED’s must be capable of operation at the fixed voltage of the DC power supply attached*** DMX-512 Is connected using the RJ-45 connectors, or (if requested) the three conductor screw down barrier strip mounted on the circuit board. ***Uses standard (not crossover) Ethernet cables*** DMX Address is selected using the 3 Rotary Switches Channel 1 will be controlled at the address shown on the rotary switches Channel 2 will be controlled at the address chosen by the rotary switches plus 1 Channel 3 will be controlled at the address chosen by the rotary switches plus 2 Channel 4 will be controlled at the address chosen by the rotary switches plus 3 RJ45 Position 001 010 100 Fuse Holder Position Note the Shaft Arrows: Address is set to 990 Selectable Modes This requires the operator to set the rotary (DMX) switches to numbers above a valid DMX address, and then press the “Learn” momentary switch to store the new operational mode into non-volatile memory. From that point on, the selected modes will be in effect - unless changed manually. After programming the desired modes, choose a valid DMX address (001-512) or 000 to operate. ***The momentary switch is accessible via a small hole in the sheet metal cover, between the output connections and the DMX selector switches (near the chassis wall).*** Liquid-Tungsten© Brightness Slew Changing brightness quickly may not be the desired look. Liquid Tungsten is a software package that smoothes out the DMX steps, to make a LED act as if it were a quartz lamp. Liquid Tungsten© Brightness Slew Rate modes: DMX address: 800 Fastest DMX address: 801 *(Default) DMX address: 802 DMX address: 803 DMX address: 804 Slowest Pulse Width Modulation Base Frequency modes: DMX address: 901 DMX address: 902 DMX address: 903 DMX address: 904 250 HZ 500 HZ 1000 HZ *(Default) 4000 HZ Channel to DMX Address modes: DMX address: 701 *(Default) Ch-1 is controlled at the DMX address chosen, Ch-2 is controlled at the address chosen + 1, Ch-3 is controlled at the address chosen + 2, and Ch-4 is controlled at the address chosen + 3 (MiniDim4) DMX address: 702 All three/four outputs are controlled at the DMX address chosen. DMX address: 703 Ch-1 is at the DMX address, Ch-2 is at the next address, (Ch-3 & Ch-4) are at the next address. DMX address: 704 USITT DMX-512 (16-bit resolution) Two DMX addresses used per channel. Ch-1 is at the first two DMX addresses, Ch-2 is at the next two DMX addresses, Ch-3 is at the next two DMX addresses, Ch-4 is at the next two DMX addresses. (MiniDim4) ***Note: To give the most user control, Liquid Tungsten is disabled in this mode*** Digital Output modes: Dim or Non-Dim This changes the output from Pulse-Width-Modulation (PWM), to full On or Off (Digital). This can be used to drive an external relay or similar device. DMX data below 50% is off, above 50% is on. DMX address: 731 DMX address: 732 DMX address: 733 DMX address: 734 Ch-1 to Digital Ch-2 to Digital Ch-3 to Digital Ch-4 to Digital (MiniDim4) DMX address: 721 DMX address: 722 DMX address: 723 DMX address: 723 Ch-1 to PWM *(Default) Ch-2 to PWM *(Default) Ch-3 to PWM *(Default) Ch-4 to PWM *(Default) (MiniDim4) DMX indicator LED (position) 4 3 2 1 Fuse Holder (position) Stand Alone / Master With the rotary switch’s at DMX address zero (0 0 0), the three/four trim pots control the level of their corresponding output channel. Status Led The “DMX Status indicator LED” shines through an opening in the sheet metal located behind the RJ-45(s)/3-pin screw barrier strip. The green LED lights when DMX is present. ***Note: this does not confirm the quality of the DMX signal*** Demo modes: (subject to change per requests) No “Learn” switch press is required to set a Demo mode. Simply set the DMX address to go into Demo mode you wish. Ch-4 is only available on the MiniDim4 Demo mode 1. Ch-1, 2, 3, 4 Overlapped Smooth Up-Down Chase, all up, then down, Repeat. DMX address: 990 DMX address: 991 Demo mode 1, Speed is set by Potentiometer #2. Demo mode 1, Fixed speed. Demo mode 2. Color dissolve, Trim Pot #3 controls the dimming of Channel #4’s output DMX address: 992 DMX address: 993 Trim Pot #2 adjustable, faster speeds. Trim Pot #2 adjustable, slower speeds Demo mode 3. Channel Step, Trim Pot #2 controls the speed of stepping DMX address: 994 DMX address: 995 CH1 > CH2 > CH3 > CH4 then start again CH4 > CH3 > CH2 > CH1 then start again Demo mode 4. Up/Down bar-graph, Trim Pot #2 controls the speed of stepping DMX address: 996 DMX address: 997 CH1 > CH1+CH2 > CH1+CH2+CH3 > CH1+CH2+ CH3+CH4 then back out Same as 996 except at a non-adjustable speed Demo mode 5. Snake Chase, Trim Pot #2 controls the speed of stepping DMX address: 998 Black > CH1 > CH1+CH2 > CH1+CH2+CH3 > CH1+CH2+CH3+CH4 > CH2+CH3+CH4 > CH3+CH4 > CH4 > [Start again at Black] WARNING Do not supply less than 8 volts DC or more than 24 volts DC. Higher voltage will cause damage to the Transient Voltage Suppression. Using voltages outside 8-24 Volts DC will void the warranty. Operating Power Derived from external DC power supply. Control circuitry uses approximately 100ma. Fuse The DC power supply input is fused at a Maximum of 7.5 AMP MTA (automotive style fuse). MiniDim3/4s are shipped with a MTA 5 fuse installed Wiring LED power output connections are made using captive screw terminals. The circuit board has labels defining the input and outputs, including polarity RJ-45 connectors Pin-1 DMX (+) Pin-2 DMX (-) Pins 7 & 8 DMX GND Pins 3, 4, 5 & 6 are pass through. Operating Temperature -20-122°F / -28-50°C Finish Enclosure: Aluminum - Black Powder Coat Paint Dimensions (H x W x L) MD3 1” x 1.75” x 5.25” MD4 1” x 2.125” x 5.5” Weight Approx. 1/3 Lbs. Operating Humidity 5-95%, (Non-Condensing) USER INFORMATION DO NOT ATTEMPT TO INSTALL OR USE the MiniDim3/4 UNTIL YOU READ AND UNDERSTAND THE INSTALLATION INSTRUCTIONS AND SAFETY LABELS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR, INSTALLER, PURCHASER, OWNER AND USER TO INSTALL, MAINTAIN AND OPERATE MiniDim3/4 IN SUCH A MANNER AS TO COMPLY WITH ALL STATE AND LOCAL LAWS, ORDINANCES, REGULATIONS AND THE AMERICAN NATIONAL STANDARDS INSTITUTE SAFETY CODE. DO NOT MODIFY OR ALTER THE MiniDim3/4. CONFIRM THE VOLTAGE/CURRENT OF THE DC POWER SUPPLY REQUIRED FOR THE LED’S TO BE CONTROLLED. 8-24 VOLT DC ONLY!! OPERATE WITHIN SPECIFIED DC VOLTAGE. ENSURE THAT POWER IS DISCONNECTED BEFORE INSTALLING, WIRING OR SERVICING. DO NOT HOT SWAP. ENSURE THE MiniDim3/4 IS OFF BEFORE CONNECTING OR DISCONNECTING FIXTURES. BLOWN FUSES CAN BE REPLACED WITHOUT REMOVING COVER. SHUT POWER OFF BEFORE REPLACING FUSES USE ONLY RECOMMENDED FUSES. REPLACE WITH SAME RATED FUSE MOUNTING TABS PROVIDED ON BOTTOM OF CHASSIS – TO THE LEFT & RIGHT OF CIRCUIT BOARD USE TWO #6 SCREWS INSTALLATION OF THE MiniDim3/4 MUST BE DONE WHILE CONFORMING TO ALL APPLICABLE NEC AND LOCAL ELECTRICAL AND SAFETY STANDARDS. THE POWER SUPPLY CONNECTED TO THE MiniDim3/4 MUST BE UL OR ETL LISTED. ONLY QUALIFIED PERSONNEL SHOULD BE ALLOWED TO PERFORM INSTALLATIONS. FOR EXTERIOR USE, THE MiniDim3/4 MUST BE ENCLOSED IN WATER RESISTANT ENCLOSURE. CONSULT FACTORY.DAMAGE BY CORROSION WILL NOT BE HONORED AS A MATERIALS DEFECT CLAIM. IT IS THE USER’S RESPONSIBILITY TO PROVIDE SUITABLE PROTECTION AGAINST CORROSIVE AGENTS SUCH AS MOISTURE AND CONDENSATION AND OTHER HARMFUL ELEMENTS. THE INSTRUCTIONS AND PRECAUTIONS SET FORTH IN THIS USER GUIDE ARE NOT NECESSARILY ALL-INCLUSIVE, OR RELEVANT TO ALL APPLICATIONS AS EVENT SYSTEMS, INC. CANNOT ANTICIPATE ALL CONCEIVABLE OR UNIQUE SITUATIONS.