Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
LCM-40-SPEC 201 201 Features Output current level selectable by DIP S.W. 180~295VAC input only Built-in active PFC function Protections: Short circuit / Over voltage / Over temperature Cooling by free air convection Fully isolated plastic case Class II power unit, no FG Built-in 0~10Vdc or PWM signal or resistance dimming function (NTC is not used) Built-in 12V/50mA auxiliary output IP20 design Temperature compensation function by external NTC No load power consumption <1W (Note.7) Power supplies synchronization function up to 10 units Suitable for indoor LED lighting applications 3 years warranty 122 202 202 122 SPECIFICATION MODEL OUTPUT LCM-40 SELECTABLE CURRENT Note.3 350mA 500mA 600mA 700mA 900mA 1050mA DC VOLTAGE RANGE 2 ~ 100V 2 ~ 80V 2 ~ 67V 2 ~ 57V 2 ~ 45V 2 ~ 40V RATED POWER 42W RIPPLE CURRENT ±5.0% RIPPLE & NOISE (max.) Note.2 700mVp-p NO LOAD OUTPUT VOLTAGE (max.) 110V CURRENT ACCURACY SETUP, RISE TIME Note.5 500ms, 80ms / 230VAC at rated power HOLD UP TIME (Typ.) VOLTAGE RANGE 65V ±5.0% 16ms/230VAC at rated power Note.4 180 ~ 295VAC FREQUENCY RANGE 254 ~ 417VDC 47 ~ 63Hz POWER FACTOR (Typ.) INPUT PF≧0.975/230VAC, PF≧0.96/277VAC at rated power (Please refer to "Power Factor Characteristic" curve) TOTAL HARMONIC DISTORTION Total harmonic distortion will be lower than 20% when output loading is 75% or higher EFFICIENCY (Typ.) Note.6 91% AC CURRENT (Typ.) INRUSH CURRENT(Typ.) 0.23A/230VAC 0.2A/277VAC COLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC MAX. No. of PSUs on 16A CIRCUIT BREAKER 26 units (circuit breaker of type B) / 44 units (circuit breaker of type C) at 230VAC LEAKAGE CURRENT <0.5mA / 240VAC SHORT CIRCUIT Constant current limiting, recovers automatically after fault condition is removed 110 ~ 130V Protection type : Shutdown o/p voltage, re-power on to recover PROTECTION OVER VOLTAGE OVER TEMPERATURE AUXILIARY POWER FUNCTION TEMP. COMPENSATION DIMMING EMC Please see "Synchronization Operation" WORKING TEMP. -30 ~ +60℃ (Refer to "Derating Curve") -40 ~ +80℃, 10 ~ 95% RH ±0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 independent,GB19510.14,GB19510.1 approved WITHSTAND VOLTAGE I/P-O/P:3.75KVAC ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55015, EN61000-3-2 Class C(≧40% rated power) ; EN61000-3-3; GB17625.1,GB17743 EMC EMISSION EMC IMMUNITY DIMENSION PACKING NOTE 20 ~ 90% RH non-condensing VIBRATION MTBF OTHERS Please see "Dimming Operation" SYNCHRONIZATION WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT SAFETY & Shut down o/p voltage, re-power on to recover 12V @ 50mA for driving fan; Tolerance±5% By external NTC(not provide with the power supply), please see "Temperature Compensation Operation" Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2KV), criteria A 260.6K hrs min. MIL-HDBK-217F (25℃) 123.5*81.5*23mm (L*W*H) 0.24Kg ; 54pcs/15Kg/1.12CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 7. 5V when the load factor 0~50%, the switching power less is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. 8. The ambient temperature derating of 5°C/1000m is needed for operating altitude greater than 2000m(6500ft). 9. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) IP65 Mechanical Specification Case No.LCM-60A Unit:mm 123.5 6.75 ※ T case: Max. Case Temperature. 6.75 6.75 110 2 TB1 68 81.5 1 2 3 4 5 6 40 T case 2- 4.2 15 1 6.75 TB3 SYN. 1 CN101 2 3 CN100 4 1 2 TB5 ON 1 2 3 4 5 6 Bottom View Terminal Pin No. Assignment(TB3) 39.3 7.8 2-M3 4 7.8 Assignment + FA N -FAN +NTC Pin No. 1 2 3 65.5 Terminal Pin No. Assignment(TB5) Assignment +Vo -Vo 23 Pin No. 1 2 SYN. Connector(CN101/CN100):JST B2B-XH or equivalent Terminal Pin No. Assignment(TB1) Pin No. 1 2 Assignment -NTC DIM+ DIM- Pin No. 4 5 6 Pin No. 1,3 2,4 Assignment AC/L AC/N Assignment + - Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent PFC fosc : 60KHz PWM fosc : 80KHz Block Diagram EMI FILTER & RECTIFIERS I/P POWER SWITCHING PFC CIRCUIT O.L.P. PFC CONTROL RECTIFIERS +12Vaux RECTIFIERS & FILTER +V -V DIM+ DIM- CURRENT LIMIT DETECTION CIRCUIT PWM CONTROL O.T.P. O.V.P. D Derating erating Curve Curve Static Characteristics 100 100 Others 90 80 80 70 203 203 40 LOAD (%) LOAD (%) 60 1050mA 20 -30 -15 0 15 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 (HORIZONTAL) 60 50 40 180 190 200 210 220 230 240 250 260 INPUT VOLTAGE (V) 60Hz 270 280 295 122 204 204 122 DIP Switch Table LCM-40 is a multiple-stage output current supply, selection of output current through DIP switch as table below. DIP S.W. 1 2 3 4 5 6 350mA ---- ---- ---- ---- ---- ---- 500mA ON ---- ---- ---- ---- ---- 600mA ON ON ---- ---- ---- ---- 700mA(Factory Setting) ON ON ON ---- ---- ON 900mA ON ON ON ON ---- ON 1050mA ON ON ON ON ON ON Io Power Factor Characteristic Constant Current Mode Constant Current Mode 1.00 0.97 350 0.88 500 0.85 600 0.82 700 0.79 900 0.76 1050 PF PF 0.94 0.91 0.73 0.70 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD (230Vac Input) 0.98 0.95 0.92 0.89 0.86 0.83 0.80 0.77 0.74 0.71 0.68 0.65 0.62 0.59 0.56 0.53 0.50 350 500 600 700 900 1050 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% (40W) LOAD (277Vac Input) (40W) EFFICIENCY vs LOAD LCM-40 series possess superior working efficiency that up to 91% can be reached in field applications. 95.0% 95.0% 90.0% 90.0% 85.0% 80.0% 350 75.0% 500 70.0% 600 65.0% 700 60.0% 900 55.0% 1050 50.0% EFFICIENCY (%) EFFICIENCY (%) 85.0% 80.0% 350 75.0% 500 70.0% 600 65.0% 700 60.0% 900 55.0% 1050 50.0% 45.0% 45.0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD (230Vac Input) 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD (277Vac Input) IP65 DIMMING OPERATION Built-in 3 in 1 dimming function, output constant current level can be adjusted through output terminal by connecting a resistance or 0 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-. Please DO NOT connect "DIM-" to "-Vo". Reference resistance value for output current adjustment (Typical) Short 10KΩ 20KΩ 30KΩ 40KΩ 50KΩ 60KΩ 70KΩ 80KΩ 90KΩ 100KΩ Single driver Resistance Multiple drivers value (N=driver quantity for synchronized Short 10KΩ /N 20KΩ /N 30KΩ /N 40KΩ /N 50KΩ /N 60KΩ /N 70KΩ /N 80KΩ /N 90KΩ /N 100KΩ /N dimming operation) Percentage of rated current 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN ----100%~108% 0 ~ 10V dimming function for output current adjustment (Typical) Dimming value 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN Output current 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 100%~108% 10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz Duty value 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN Output current 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 100%~108% Duty cycle of output current VS Dimming input 100% when DIM+/DIM- are open circuit. 100% 90% Duty cycle of output current 80% Note 70% 60% 50% 40% 30% 20% 10% 0% 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N Dimming input 0~10V Duty cycle of 10V PWM (frequency range = 100~3KHz) Short~100KΩ /N resistance (N=driver quantity for synchronized dimming operation ) Note : 1. Min. dimming level is about 6% 2. The output current is not defined when 0%< I out<6% 3. The output current could drop down to 0% when dimming input is about 0 KΩ or 0Vdc, or 10V PWM signal with 0% duty cycle 205 205 122 206 206 122 SYNCHRONIZATION OPERATION 10 drivers(max.) synchronization (1 master + 9 slaves) Maximum cable length between each units : 20 meter. SYN. - - LCM-40 (Slave 1) + + + + LCM-40 (Master) 20m SYN. - - + + SYN. - - LCM-40 (Slave 2) 20m TEMPERATURE COMPENSATION OPERATION NTC derating curve 105 100 220KO 220KΩ Output Io (%) 95 330KO 330KΩ 470KO 470KΩ 90 85 80 75 70 65 55 60 65 70 75 80 85 90 95 Sensed Temperature(degree) LCM-40 have the built-in temperature compensation function (T↑,Io↓). By connecting a temperature sensor (NTC resistor) between th e NTC +/terminal of LCM-40 and the detecting point on the lighting system or the surrounding environment, output current of LCM-40 coul d be correspondingly changed to ensure the long life of LED. 1.LCM-40 can still be operated well when the NTC resistor is not connected and the value of output current will be the current level that you set through the DIP switch. 2. NTC resistance Output Current 220K < 60℃, 100% of the rated current (corresponds to the setting current level) > 60℃, output current begin to reduce, details please refer to the curve. 330K < 70℃, 100% of the rated current (corresponds to the setting current level) > 70℃, output current begin to reduce, details please refer to the curve. 470K < 80℃, 100% of the rated current (corresponds to the setting current level) > 80℃, output current begin to reduce, details please refer to the curve. Notes: 1. MW does not offer the NTC resistor and all the data above are measured by using THINKING TTC03 series. 2. If other brands of NTC resistor is applied,please check the temperature curve first. IP65