 2x22 AWG STP + 2 x18 AWG OUTDOOR CONTROL CABLE
Part Number:
9846229101
Applications:
Control and audio applications, Indoor and outdoor use,
Short-range, low-frequency signals
General Construction: The cable contains:
1 - 22 AWG shielded twisted pair for RS-485 protocol
application.
1 - 18 AWG unshielded twisted pair for AC application.
All pairs are cabled together and jacketed with Black PVC,
for indoor and outdoor use.
This cable has stranded conductors and can be used in
portable,
RS-485 data and control applications.
Outer Jacket Material: FR-PVC
Outer Diameter:
10.5 mm nom.
Weight:
95 kg/km
Design & Materials
Detailed Construction:
Teldor Cables & Systems Ltd. ("Teldor") reserves the right to make changes to the products described in this catalog without prior
notice. Teldor does not assume any liability which may occur due to the use of the products described herein. The information
contained in this catalog is the proprietary property of Teldor, and may not be used, reproduced or disclosed to others, in whole or in
part, without the written authorization of Teldor.
TELDOR Cables & Systems Ltd. - Ein-Dor, 19335 ISRAEL Tel: +972-4-6770555 Fax: +972-4-6770650
P/N: 9846229101
1 / 2
Detailed Construction:
Basic Wires:
22 AWG:
Conductor: Stranded TC, 19x0.16 mm, 22 AWG.
Insulation: FPE
Total number of pairs: 1
Color Code: White x Blue.
Individual Shield: Polyester-aluminum tape providing 100% coverage,
laid in close contact with 22 AWG TC (7x0.25) drain wire.
Electrical Properties:
DC Resistance: 53.1 Ohm/Km max. @ 20C.
Voltage Rating: 300 V rms.
Dielectric Strength: 1000 volts/1 minute between conductors.
500 volts/1 minute between
conductors to shield.
Impedance: 100 +/-20 Ohm.
Capacitance: 40 pF/m nom
18 AWG:
Conductor: Stranded TC, 19x0.25 mm, 18 AWG.
Insulation: PVC
Total number of pairs: 1
Color Code: Black x Red.
Electrical Properties:
DC Resistance: 22.0 Ohm/Km max. @ 20C.
Voltage Rating: 300 V rms.
Dielectric Strength: 1000 volts/1 minute
Cable Lay: All pairs are cabled together and wrapped with a separation tape.
Binder:
Polyester
Total number of wires:
4
Total number of conductor units:
2
Outer Jacket Thickness:
1.2 mm
Outer Jacket Color:
Black
Marking:
Per request
Standards
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
Performance
Dielectric Strength:
1000 V/minute
Dielectric Strength to Shield:
500 V/minute
Voltage Rating:
300 V
Max. Operating Temperature:
+70 °C
Min. Operating Temperature:
-30 °C
Prepared By
Revised By
Version Num
Modified on
Dov Shaham
Dov Shaham
1.3
27-01-2008
Teldor Cables & Systems Ltd. ("Teldor") reserves the right to make changes to the products described in this catalog without prior
notice. Teldor does not assume any liability which may occur due to the use of the products described herein. The information
contained in this catalog is the proprietary property of Teldor, and may not be used, reproduced or disclosed to others, in whole or in
part, without the written authorization of Teldor.
TELDOR Cables & Systems Ltd. - Ein-Dor, 19335 ISRAEL Tel: +972-4-6770555 Fax: +972-4-6770650
P/N: 9846229101