FLOWCOMPUTER WITH TEMPERATURE COMPENSATION FOR DATASHEET F126-EL – FLOWCOMPUTER CORRECTED LIQUID VOLUME Advantages Signal output • Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it! • Intrinsically Safe available - ATEX and IECEx approval for gas and dust applications. • Programming can be done by your own crew, with the sensible menu-driven structure, saving cost and irritation. Know one, know them all! • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors! • (0)4 - 20mA / 0 - 10V DC according to compensated flow rate. • Scaled pulse output according to accumulated total. Signal input Features • Calculates compensated flow rate, total and accumulated total. • Displays actual line temperature. • Selectable on-screen engineering units; volumetric or mass. • 7 digit resettable total. • 11 digit accumulated total. • Explosion/flame proof available. • Full Modbus communication RS232/485/TTL. • Loop or battery powered, 8 - 24V AC/DC or 115 - 230V AC power supply. • Sensor supply 3 / 8.2 / 12 / 24V DC. 1 Flow • Ability to process all types of flowmeter signals: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), Active pulse signals, (0)4 - 20mA, 0 - 10V DC. Temperature • PT100 - 2 or 3 wire. • (0)4 - 20mA / 0 - 10V DC. Applications • The F-Series is your first and safest choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, salty atmosphers and temperatures between -40°C up to +80°C (-40°F up to 176°F). • Applications where nett flow calculation at base conditions is desired without the influence of thermal product expansion. For DIN panel mount indicators, check our D-Series. General information Introduction Signal input The flowcomputer Model F126-EL has been developed to calculate corrected liquid volume at normal conditions for generic products. The corrected volumetric flow is calculated by using the thermal expansion coefficient algorithm stored in the flowcomputer. The reference temperature can be defined as desired, e.g. 15°C, 20°C or 60°F. A typical application is flow calculation of water, fuel or chemicals at base conditions. The flowcomputer measures the uncorrected volumetric flow and actual line temperature. The F126-EL will accept most pulse and analog input signals for flow. The analog flow input is available with lineair and square root calculation and even as 4 - 20mA input loop powered. For temperature measurement, 2 or 3 wire PT100 elements or sensors with a (0)4 - 20mA / 0 - 10V DC output signal can be used. Communication Display All process data and settings can be read and modified manually or through the Modbus communication link (RS232 / RS485). Full Modbus functionality remains available for the Intrinsically Safe version (TTL). The display has large 17mm (0.67”) and 8mm (0.31”) digits which can be set to show flow rate, total and temperature. On-screen engineering units are easily configured from a comprehensive menu. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute. Hazardous areas This model has been ATEX and IECEx certified Intrinsically Safe for gas and dust applications, with an allowed ambient temperature of -40°C to +70°C (-40°F to +158°F). A flame proof Configuration All configuration settings are accessed via a simple operator menu which can be password protected. Each setting is clearly indicated with an alphanumerical description, which avoids confusing abbreviations and baffling codes. Once familiar with one F-series product, you will be able to program all models in the series without a manual. All settings are safely stored in EEPROM memory in the event of sudden power failure. Ex d enclosure with ATEX certification is also available. Enclosures Various types of enclosures can be selected, all ATEX and IECEx approved. As standard the F126-EL is supplied in an GRP panel mount enclosure, which can be converted to an IP67 / NEMA Type4X GRP field mount enclosure by the addition of a back case. Most popular is our rugged aluminum field mount enclosure with IP67 / NEMA Type4X rating. Both European or U.S. cable gland entry threads are available. Analog output signal The calculated flow rate is re-transmitted with the (0)4 - 20mA or 0 - 10V DC output signal. The output signal is updated eight times per second with a filter function being available to smoothen out the signal if desired. The output value is user defined in relation to the flow rate, e.g. 4mA equals to 15Nm3/Hr and 20mA equals to 2000Nm3/Hr. The output signal can be passive, active or isolated where the passive output type will loop power the F126-EL as well. Overview application F126-EL Pulse output Pulse output The scaleable pulse output, reflects the count on the accumulated display. The pulse length is user defined from 0.001 second up to 9.999 seconds. The maximum output frequency is 500Hz. The output signal can be passive NPN, active PNP or an isolated electro-mechanical relay. Temperature input 2 Analog output Communication link Flowmeter input F126-EL 0.9" 0.9" 14mm 1 2 / "NPT 15mm 38mm F126-EL 24mm 24mm 36mm 36mm 1 2 / "NPT 15mm HP 1 2 / "NPT HT 6 x M12 HJ Ø22 ( 7/8") Ø22 ( 7/8") Ø22 ( 7/8") HK 1.18" 1.18" Flat bottom, no holes available. 1 /2"NPT HU 4 x M20 x 1.5 HV HZ 3 + Display example - 90 x 40mm (3.5” x 1.6”) + + PL: input loop powered (terminals GND - 1 - 2 are not available) PB / PC: battery powered Internal long life Lithium battery AP: 8 - 30V DC Output loop powered - ZB: Backlight: 12 - 24V DC - PX: 8 - 30V DC 30mm (1.18") 30mm (1.18") - Ø12 PM: 115 - 230V AC 24mm 24mm 36mm 36mm PF: 24V DC HH + M20 x 1,5 Ø20 + 12mm 12mm - Ø20 PF: 24V AC M20 x 1,5 + + = Note: Only available with Type:P = OR: mech. relay HG 07 08 I+ I+ I+ I+ I+ U U+ AU: 0 - 10V I AP: 4 - 20mA I- AI: 4 - 20mA I- AF: 4 - 20mA I AB: 0 - 20mA I - - + I+ I+ A - PL: 4 - 20mA U+ U: 0 - 10V A: (0)4 - 20mA + P: active signal P: namur P: PNP + + + + P: reed switch / NPN 11 U+ TU: 0 - 10V I+ TA: (0)4 - 20mA 12 + + 14 13 Ø16 10 09 P: coil Ø22 ( 7/8") OT: passive trans. 25mm 25mm - HO HF AA: 4 - 20mA M16 x 1,5 Ø20 06 30mm 30mm 05 HN 15 HD OA: active 24V DC M20 x 1,5 PG9 PD - XI: 16 - 30V DC 12mm 12mm 16 GRP PD: 8 - 24V DC M20 x 1,5 Ø16 04 25mm HM HE 03 25mm HL 17 112 mm (4.40") 02 /2"NPT 18 19 21 + TP: PT100 3-wire + TP: PT100 2-wire 20 22 TEMPERATURE INPUT Ø 7mm (0.27") TEMPERATURE INPUT Aluminum & GRP field / wall mount enclosures 01 30mm 30mm 23 24 panel cut-out 00 M20 x 1,5 25 26 27 A A DTR +12V RXD CT: TTL Intrinsically Safe CI: RS485 - 4 wire 28 RXD CH: RS485 - 2 wire DTR +12V CB: RS232 TXD B B TXD 29 COMMUNICATION 98 (3.86") 115 (4.53") FLOWMETER INPUT 60 mm (2.36") 130 mm (5.12") PD: 8 - 24V AC 1 ANALOG OUTPUT 1.18" 22,50mm Aluminum PULSE OUTPUT M16 x 1,5 Ø 7mm (0.27") POWER REQUIREMENTS / "NPT HA 22,50mm (0.9") 75 mm (2.95") 22,50mm 30mm 30mm 22,50mm HB & HC enclosures 17mm 0.9" 130 mm (5.12") 14mm 1 2 22,50mm 29 mm (1.14") 22,50mm (0.9") 22,50mm 1.18" 22,50mm PG9 17mm 31 mm (1.22") 15mm 120 mm (4.72") Y 30 Z 31 Aluminum & GRP panel mount enclosure + 16mm 120 mm (4.72") Dimensions enclosures Terminal connections Typical wiring diagram F126-P-(AP)-CH-EL-(OT)-PB-(PX)-TP Typical wiring diagram F126-P-AP-CH-EL-OT-PX-TA BATTERY POWERED TERMINAL CONNECTORS F100-series OUTPUT LOOP POWERED TERMINAL CONNECTORS F100-series Modbus communication type CH: RS485 - 2 wire 29 29 A 28 Common ground 26 Common ground 28 A B 26 B Modbus communication type CH: RS485 - 2 wire 22 Signal Temperature input type TP: PT100 3 - wire 21 Signal 20 Supply Common ground 10 14 Supply * 11 Circuit depends on type of signal 11 Flowmeter input type: P pulse Signal Signal Common ground 09 Circuit depends on type of signal Common ground Supply * 12 13 Signal Flowmeter input type: P pulse 10 AP-PX will power the unit; (the battery will be disabled automatically untill power is disconnected). Temperature input type TA: (0)4 - 20mA Supply * 09 Circuit depends on type of signal Please note: AP-PX may be used in combination with the battery! 08 123456 Common ground *Supply voltage: 1.2 / 3.2V DC to sensor 00 01 Power supply type PX: 8 - 30V DC (not used in this example) Pulse output type OT: passive transistor 05 Common ground 8 - 30V DC Analog output type AP: passive 4 - 20mA (loop powered) e.g. counter 06 07 07 Pulse output type OT: passive transistor (not used in this example) 05 06 Common ground 00 01 Common ground indicator Common ground - 08 + Common ground Analog output type AP: (not used in this example) Power supply type PX: 8 - 30V DC (not used in this example) *Supply voltage: 1.2 / 3.2V DC to sensor 4 F126-EL Typical wiring diagram F126-P-AI-CI-EL-OA-PD-TA 24V AC / DC POWER SUPPLY RXD 28 DTR +12V 26 Common ground 29 TXD 26 Common ground Modbus communication type CB: RS232 27 31 A Modbus communication type CI: RS485 - 4 wire 29 B 115 - 230V AC POWER SUPPLY TERMINAL CONNECTORS F100-series 28 Y 30 TERMINAL CONNECTORS F100-series Z Typical wiring diagram F126-A-AA-CB-EL-OX-PM-TP 22 Signal Temperature input type TP: PT100 3 - wire 21 Signal 14 Supply * Signal 13 12 08 8 - 30V DC 00 Analog output type AA: active 4 - 20mA 11 Note: Digital output not available with Type: A / U 02 Power supply type PM: 115 - 230V AC 01 Power supply type PD: 8 - 24V AC / DC 8 - 24V DC - - 02 Main supply 8 - 24V AC + + 01 10 06 Pulse output type OA: active 24V DC pulse Common ground *Supply voltage: 1.2 / 3.2 / 8.2 / 12 / 24V DC to sensor F126-EL indicator 05 e.g. counter 05 06 07 - Common ground - Common ground 123456 Common ground Analog output type AI: passive isolated 4 - 20mA 09 09 Common ground indicator Flowmeter input type A: (0)4 - 20mA Signal 08 Flowmeter input type: P pulse + Common ground 10 Signal Supply * 07 11 Circuit depends on type of signal Supply * 00 Common ground Circuit depends on type of signal Temperature input type TA: (0)4 - 20mA + Circuit depends on type of signal 20 Supply *Supply voltage: 3.2 / 8.2 / 12 / 24V DC to sensor 5 N L1 Hazardous area applications Configuration example IIB / IIIC and IIC F126-P-(AP)-(CT)-EL-(OT)-PC-TP-XI - Battery powered unit The F126-EL-XI has been certified according ATEX and IECEx by DEKRA for use in Intrinsically Safe applications with an ambient temperature of -40°C to +70°C (-40°F to +158°F). • The ATEX markings for gas and dust applications are: II 1 G Ex ia IIB/IIC T4 Ga II 1 D Ex ia IIIC T100 °C Da. • The IECEx markings for gas and dust applications are: Ex ia IIC/IIB T4 Ga and Ex ia IIIC T100 °C Da. It is allowed to connect up to four barriers in IIB/IIIC applications or one barrier in IIC applications. Consult the certificate for the maximum input and output values of the circuits. Full functionality of the F126-EL remains available, including 4 - 20mA output according to the flow rate and Modbus communication (type CT). Power supply type PD-XI offers a 8.2V sensor supply e.g. for one Namur sensor and a temperature sensor. An ATEX approved flame proof Ex d enclosure is available as well. Please contact your supplier for further details. HAZARDOUS AREA 29 RXD 28 DTR +12V Common ground SAFE AREA Modbus communication type CT: TTL Possible for battery powered applications (not used in this example). Please note: communciation type CT is not allowed in IIC applications. 26 TXD 27 TERMINAL CONNECTORS F100-series 22 Signal Temperature input type TP: PT100 3 - wire 21 Signal 20 Supply 11 Supply * Common ground Ci is negligibly small Flow meter input type: P pulse Analog output type AP: passive 4 - 20mA (not used in this example). Pulse output type OT: passive transistor (not used in this example) 05 06 Common ground 07 08 Common ground 10 Signal 09 Circuit depends on type of signal Certificate of conformity KEMA 03ATEX1074 X • IECEx DEK 11.0042X Please note: type AP may be used in combination with the battery (type PC), but only in IIB applications! Common ground 00 01 AP will power the unit (output loop powered); the battery will be disabled automatically till power is disconnected). * Note sensor supply voltage: 1.2V DC for coil sensors or 3.2V DC for other pulse sensors. 6 F126-EL Configuration example IIB / IIIC and IIC - F126-P-AP-(CT)-EL-OT-(PX)-TP-XI - Output loop powered HAZARDOUS AREA TERMINAL CONNECTORS F100-series SAFE AREA RXD Uo=max 30V 28 TXD 29 Modbus communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications. + 27 26 Common ground Po=max 850mW e.g. PC For example: MTL5051 - DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL * Note: Communication only allowed when configured as IIB / IIIC. 22 Signal Temperature input type TP: PT100 3 - wire 21 Signal 11 Supply * Flow meter input type: P pulse 09 Analog output type AP: passive 4 - 20mA (output loop powered) 06 Pulse output type OT: passive transistor 123456 e.g. counter 05 Ci is negligibly small Uo=max 30V Io=max 100mA 07 08 Ci = 17nF Po=max 750mW Uo=max 30V - Common ground e.g. indicator - Common ground Ci is negligibly small + Common ground 10 Signal + Circuit depends on type of signal 20 Supply Po=max 750mW Io=max 100mA POWER SUPPLY e.g. MTL 5525 and / or REPEATER e.g. MTL 5541 POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 e.g. indicator 123456 e.g. counter 01 Note: above values are safety values. Consult the technical specification for operational values. PX: Not used in this example 00 Common ground * Note sensor supply voltage: 1.2V DC for coil sensors or 3.2V DC for other pulse sensors. F126-EL 7 Configuration example IIB / IIIC and IIC - F126-A-AF-(CT)-EL-OX-PD-TA-XI - Power requirement 16 - 30V DC HAZARDOUS AREA TERMINAL CONNECTORS F100-series SAFE AREA RXD Uo=max 30V 28 TXD 29 Modbus communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications. Po=max 850mW e.g. PC For example: MTL 5051 26 - Common ground 27 + DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL * Note: Communication only allowed when configured as IIB / IIIC. 14 Supply * 13 Ci is negligibly small 12 Common ground 11 Supply * Flow meter input type: A (0)4 - 20mA Signal Ci is negligibly small Ci = 17nF Analog output type AF: passive floating 4 - 20mA e.g. indicator 07 08 Common ground 10 Circuit depends on type of signal Temperature input type: TA (0)4 - 20mA Signal 09 Circuit depends on type of signal TOTAL Co OF ALL CONNECTED ANALOG APPARATUS IN IIC APPLICATIONS MAY NOT EXCEED 66nF MINUS 17nF (17nF IS USED BY THE ANALOG OUTPUT SIGNAL TERMINAL 7 + 8). 02 Note: Digital output not available with Type: A / U Power supply type PD: 16 - 30V DC (please note: PD and battery supply (type PC) is NOT allowed in IIC applications). 00 Uo=max 30V Io=max 100mA - Common ground 01 + Main supply Po=max 750mW POWER SUPPLY For example MTL 5525 Note: above values are safety values. Consult the technical specification for operational values. * Note power supply type PD: the supply voltage to pulse sensors is maximum 8.7V (Uo=max 8.7V Io=max 25mA Po=max 150mW) and to analog sensors as connected to terminal 1 (internally linked). 8 F126-EL Configuration example IIB / IIIC - F126-A-AF-CT-EL-OX-(PC)-(PD)-TA-XI - Power requirement 16 - 30V DC or battery powered HAZARDOUS AREA TERMINAL CONNECTORS F100-series SAFE AREA TXD 29 Modbus communication type CT: TTL 28 Uo=max 30V RXD 26 14 12 Supply * 11 Ci is negligibly small + 09 e.g. indicator Ci = 17nF Uo=max 30V Io=max 100mA - 10 Po=max 750mW REPEATER For example MTL 5541 Flow meter input type A: (0)4 - 20mA Signal Analog output type AF: passive floating 4 - 20mA Po=max 750mW Uo=max 30V Io=max 100mA 07 - 08 Uo=max 30V Io=max 100mA + Circuit depends on type of signal Ci is negligibly small - 13 Signal Common ground For example: MTL5051 Temperature input type TA: (0)4 - 20mA + Circuit depends on type of signal Supply * Common ground Po=max 850mW e.g. PC - Common ground 27 + DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL REPEATER For example MTL 5541 REPEATER e.g. MTL 5541 Po=max 750mW e.g. indicator Note: above values are safety values. Consult the technical specification for operational values. 01 00 Common ground Uo=max 30V Io=max 100mA Power supply type PD: 16 - 30V DC - Main supply Due to analog output type AF, the unit has to be powered with battery type PC or with external power supply type PD. + 02 Note: Digital output not available with Type: A / U Po=max 750mW POWER SUPPLY For example MTL 5525 Note: above values are safety values. Consult the technical specification for operational values. * Note power supply type PD: the supply voltage to pulse sensors is maximum 8.7V (Uo=max 8.7V Io=max 25mA Po=max 150mW) and to analog sensors as connected to terminal 1 (internally linked). F126-EL 9 Data protection Technical specification Type General Display Type Dimensions Digits Refresh rate Option ZB Note ZB Password High intensity reflective numeric and alphanumeric LCD, UV-resistant. 90 x 40mm (3.5” x 1.6”). Seven 17mm (0.67") and eleven 8mm (0.31") digits. Various symbols and measuring units. User definable: fast, 1sec , 3sec, 15sec, 30sec, off. Transflective LCD with white LED-backlight. Good readings in full sunlight and darkness. Only available for safe area applications. Enclosure General Window Sealing Control keys Polycarbonate window. Silicone. Three industrial micro-switch keys. UV-resistant silicone keypad. Aluminum wall / field mount enclosures Ambient temperature General Safe areas -40°C to +80°C (-40°F to +176°F). Intrinsically Safe -40°C to +70°C (-40°F to +158°F). Dimensions Weight Power requirements Analog output loop powerd, 8 - 30V DC. Power consumption max 0.5 Watt. Type PB Long life Lithium battery - life-time depends upon settings and configuration - up to 5 years. (requires PD, PL or PX) Type PC Intrinsically Safe long life lithium battery - life-time depends upon settings and configuration - up to 5 years. (requires XI and PD or PX) Type PD 8 - 24V AC / DC ± 10%. Power consumption max. 10 Watt. Intrinsically Safe: 16 - 30V DC; power consumption max. 0.75 Watt. F Type P 24V AC / DC ± 10%. Power consumption max. 15 Watt. Type PL Input loop powered from sensor signal 4 - 20mA (type “A”) - requires types AI and OT (not Xi). Type PM 115 - 230V AC ± 10%. Power consumption max. 15 Watt. Type PX 8 - 30V DC. Power consumption max. 0.5 Watt. Type ZB 12 - 24V DC ± 10%. Power consumption max. 1 Watt. Note PB/PF/PM Not available Intrinsically Safe. Note PF/PM The total consumption of the sensors and outputs may not exceed 400mA @ 24V. Note For Intrinsically Safe applications, consult the safety values in the certificate. EEPROM backup of all settings. Backup of running totals every minute. Data retention at least 10 years. Configuration settings can be password protected. Type HA Type HL Type HM Type HN Type HO Type HP Type HT Type HU Type HV Type HZ Type AP Die-cast aluminum wall/field mount enclosure IP67 / NEMA Type4X with 2-component UV-resistant coating. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 1100 gr. Cable entry: 2 x PG9 and 1 x M20. Cable entry: 3 x 1/2" NPT. Cable entry: 2 x M16 and 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2" NPT. Cable entry: 3 x 1/2" NPT. Cable entry: 4 x M20. Cable entry: no holes. GRP wall / field mount enclosures General Dimensions Weight Type HD Type HE F Type H Type HG Type HH Type HJ Type HK GRP wall/field mount enclosure IP67 / NEMA Type4X, UV-resistant and flame retardant. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 600 gr. Cable entry: no holes. Cable entry: 2 x Ø 16mm and 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8"). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8"). Flat bottom, cable entry: no holes. Sensor excitation Type PB/PC/PX Note Type PD Type PD-XI Note Type PF / PM 3V DC for pulse signals and 1.2V DC for coil pick-up. This is not a real sensor supply. Only suitable for sensors with a very low power consumption like coils (sine wave) and reed-switches. 1.2 / 3 / 8.2 / 12 / 24V DC - max. 50mA @ 24V DC. 1.2 / 3 / 8.2V DC - max. 7mA @ 8.2V DC and mains power supply voltage (as connected to terminal 1). In case PD-XI and signal A or U: the sensor supply voltage is according to the power supply voltage connected to terminal 1. The sensor supply of the second analog input is fixed 8.2V DC. 1.2 / 3 / 8.2 / 12 / 24V DC - max. 400mA @ 24V DC. Panel mount enclosures Dimensions Panel cut-out Type HB Weight Type HC Weight Hazardous area Intrinsically Safe (Type XI) ATEX certification IECEx certification Ambient Ta Terminal connections Type Removable plug-in terminal strip. Wire max. 1.5mm2 and 2.5mm2. Directives & Standards EMC Low voltage RoHS ATEX / IECEx IP & NEMA Directive 2014/30/EU, FCC 47 CFR part 15. Directive 2014/35/EU Directive 2011/65/EU Directive 2014/34/EU, IEC 600079-0, IEC 60079-11. EN 60529 & NEMA 250 130 x 120 x 60mm (5.12" x 4.72" x 2.36") - W x H x D. 115 x 98mm (4.53" x 3.86") L x H. Die-cast aluminum panel mount enclosure IP65 / NEMA Type4X. 600 gr. GRP panel mount enclosure IP65 / NEMA Type4X, UV-resistant and flame retardant. 450 gr. II 1 G Ex ia IIB/IIC T4 Ga. II 1 D Ex ia IIIC T100 °C Da. Ex ia IIC/IIB T4 Ga. Ex ia IIIC T100 °C Da. -40°C to +70°C (-40°F to +158°F). Explosion proof (Type XF) ATEX certification F Type X Weight Note 10 II 2 G / Ex d IIB T5 Gb. II 2 D / Ex t IIIB T100 °C Db. Dimensions of enclosure: 300 x 250 x 200mm (11.8" x 9.9" x 7.9") L x H x D. Appr. 15kg. IECEx available on request. F126-EL Signal inputs Flowmeter Digital output Function Frequency Type P Coil / sine wave (HI: 20mVpp or LO: 80mVpp sensitivity selectable), NPN/PNP, open collector, reedswitch, Namur, active pulse signals 8 - 12 and 24V DC. Frequency Minimum 0Hz - maximum 7kHz for total and flow rate. Maximum frequency depends on signal type and internal low-pass filter. E.g. reed switch with low-pass filter: max. frequency 120Hz. K-Factor 0.000010 - 9,999,999 with variable decimal position. Low-pass filter Available for all pulse signals. Option ZF coil sensitivity 10mVpp. Type A (0)4 - 20mA. Analog input signal can be scaled to any desired range within 0 - 20mA. Type U 0 - 10V DC. Analog input signal can be scaled to any desired range within 0 - 10V DC. Accuracy Resolution: 14 bit. Error < 0.025mA / ± 0.125% FS. Low level cut-off programmable. Span 0.000010 - 9,999,999 with variable decimal position. Update time Four times per second. Voltage drop Type A: 2.5V @ 20mA. Load impedance Type U: 3kOhm. Relationship Linear and square root calculation. Note For signal type A and U: external power to sensor is required; e.g. type PD. Temperature Accuracy Update time Type TA Span Offset Voltage drop Type TP Range Option ZV Type TU Type OA Type OR Type OT Note: Communication option Function Protocol Speed Addressing Type CB Type CH Type CI Type CT Resolution: 14 bit. Error < 0.025mA / ± 0.125% FS. Low level cut-off programmable. Four times per second. (0)4 - 20mA. Analog input signal can be scaled to any desired range within 0 - 20mA. 0.000010 - 9,999,999 K with variable decimal position. Digits 11 digits. Units / decimals According to selection for total. Note Can not be reset to zero. Line temperature Digits Units Decimals 0.00 - 99,999.99 K. 2.5V @ 20mA. 2 or 3 wire PT100. -100°C to +200°C (-148°F to 392°F). Accuracy 3°C (5.4°F). Range: -200°C to +800°C (-328°F to 1832°F). Accuracy 3°C (5.4°F). 0 - 10V DC. Analog input signal can be scaled to any desired range within 0 - 10V DC. 0.000010 - 9,999,999 K with variable decimal position. Update time Type AA Type AB F Type A Type AI Type AP Type AU F126-EL 6 digits. °C, °F or K. 1. Operator functions Displayed functions • Compensated flow rate. • Compensated total and accumulated total. • Actual line temperature. • Total can be reset to zero by pressing the CLEARkey twice. Total Digits Units Decimals Note For signal TA and TU: power supply to temperature sensor is required; e.g. PD. 7 digits. L, m3, GAL, USGAL, kg, lb, bbl, no unit. 0 - 1 - 2 or 3. Total can be reset to zero. Flow rate Signal outputs Analog output Function Accuracy Reading display information, reading / writing all configuration settings. Modbus RTU. 1200 - 2400 - 4800 - 9600 baud. Maximum 255 addresses. RS232 RS485 2-wire RS485 4-wire TTL Intrinsically Safe. Operational Accumulated total Span Offset 0.00 - 99,999.99 K. Load impedance 3kOhm. Note 1 Pulse output - transmitting accumulated total. Max. 500Hz. Pulse length user definable between 0.001 second up to 9.999 seconds. One active 24V DC transistor output (PNP); max. 50mA per output (requires -PD, PF, PM or PX). One electro-mechanical relay output - isolated; max. switch power 230V AC (N.O.) - 0.5A per relay (requires PF or PM). One passive transistor output (NPN) - not isolated. Max. 50V DC - 300mA per output. Digital output only available for Type: P (pending for Type: A / U) Digits Units Transmitting compensated flow rate. 10 bit. Error < 0.05%. Analog output signal can be scaled to any desired range. Eight times per second. Active 4 - 20mA output (requires PD, PF, PM or PX). Active 0 - 20mA output (requires PD, PF, PM or PX). Passive floating 4 - 20mA output for Intrinsically Safe applications (requires XI + PD or PX). Passive galvanically isolated 4 - 20mA output - also available for battery powered models. Passive 4 - 20mA output - not isolated. Unit will be loop powered. Active 0 - 10V DC output (requires PD, PF, PM or PX). Decimals Time units 7 digits. mL, L, m3, Gallons, kg, Ton, lb, bl, cf, RND, ft3, scf, Nm3, Nl, igal - no units. 0 - 1 - 2 or 3. /sec - /min - /hr - /day. Flow equations Type EL Formula Normal temp. 11 Corrected liquid volume. Qnormal = Q x (1 + _ (Tnormal - T)) where _ = thermal expansion coefficient. Default: 273.15 K - any temperature can be set. Ordering information Standard configuration: F126-P-AP-CX-EL-HC-OT-PX-TA-XX-ZX. Ordering information: F126 -_ -A _ Flowmeter input signal A P U -C _ -EL -H _ -O _ -P _ -T _ -X _ -Z _ (0)4 - 20mA input. (Digital ouput is pending) Pulse input: coil, npn, pnp, namur, reed-switch. 0 - 10V DC input. (Digital ouput is pending) Analog output signal AA AB F A AI AP AU Active 4 - 20mA output - requires PD, PF, PM or PX. Active 0 - 20mA output - requires PD, PF, PM or PX. I.S. floating 4 - 20mA output - requires XI + PD or PX. Isolated 4 - 20mA output. Passive 4 - 20mA output, loop powered unit. Active 0 - 10V DC output - requires PD, PF, PM or PX. Communication CB CH CI CT CX Communication RS232 - Modbus RTU. Communication RS485 - 2wire - Modbus RTU. Communication RS485 - 4 wire - Modbus RTU. Intrinsically Safe TTL - Modbus RTU. No communication. EL Corrected liquid volume. HB HC Aluminum enclosure. GRP enclosure. Flow equations Panel mount enclosures - IP65 / NEMA Type4X GRP field / wall mount enclosures - IP67 / NEMA Type4X HD HE F H HG HH HJ HK Cable entry: no holes. Cable entry: 2 x Ø 16mm & 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8”). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8”). Flat bottom, cable entry: no holes. Aluminum field / wall mount enclosures - IP67 / NEMA Type4X HA HL HM HN HO HP HT HU HV HZ Cable entry: 2 x PG9 + 1 x M20. Cable entry: 2 x 1/2”NPT. Cable entry: 2 x M16 + 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2”NPT. Cable entry: 3 x 1/2”NPT. Cable entry: 4 x M20. Cable entry: no holes. OA OR OT One active transistor outputs - requires PD, PF, PM or PX. One mechanical relay outputs - requires PF or PM. One passive transistor outputs - standard configuration. requires P Digital output signal Power requirements PD F P PL PM PX 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC. 24V AC/DC + sensor supply. Input loop powered from sensor signal type “A” - requires AI (not XI). 115 - 230V AC + sensor supply. Basic power supply 8 - 30V DC (no real sensor supply). Additional battery supply (optional) PB PC Lithium battery powered - requires PD, PL or PX. Lithium battery powered - Intrinsically Safe - requires XI, and PD or PX. TA TP TU (0)4 - 20mA input. PT100 input. 0 - 10V DC input. Temperature input signal XI F X XX Intrinsically Safe, according ATEX and IECEx. Ex d enclosure - 3 keys according ATEX. Safe area only. ZB F Z ZV ZX Backlight. Coil input 10mVpp. PRTD-range -200°C / +800°C. No options. Other options The bold marked text contains the standard configuration. Available Intrinsically Safe. Specifications are subject to change without notice. Fluidwell bv P.O. Box 6 5460 AA - Veghel - The Netherlands Telephone: +31 (0)413 343 786 Telefax: +31 (0)413 363 443 email: [email protected] Internet: www.fluidwell.com 12 Copyright: Fluidwell bv - 2017 - F126EL-DATA-EN-V1704 Hazardous area