Download Now!

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
NEW STANDARD AC DRIVE
NEW STANDARD AC DRIVE
S100
1] LV Drive Line-up
2] Target application
LV Drive Line-up
Línea Starvert vigente
Futura línea de drivers LS
Performance
• Variador para elevadores
L100
(5.5~22kW)
3] Fame design
4] General spec.
5] Features
6] Option
iV5
(2.2~800kW)
• Alto rendimiento
7] Comparison
8] Launching schedule
• Variador premiun
• Variador vector type
X100
(0.75~800kW)
iS7
(0.75~375kW)
• Ventilación y bombeo
iP5A
(5.5~450kW)
• Variador HVAC
H100
S100
(0.4~75kW) (5.5~800kW)
• Variador estándar
• Alto rendimiento compacto
iG5A
(0.4~22kW)
iC5
/iE5
(0.1~2.2kW)
1/32
• Clase económica
Capacity(kW)
C100
/E100
(0.1~7.5kW)
• Compactos y económicos
Capacity(kW)
NEW STANDARD AC DRIVE
S100
Aplicaciones objetivo
Dificultad técnica
1] LV Drive Line-up
3] Fame design
5] Features
6] Option
Heavy Duty applications
Press, Winding
& Cart
S100 Target areas
2/32
Crane, Hoist
& E/L
Rotation / Fluid
8] Launching schedule
Normal Duty applications
Horizontal / Friction
7] Comparison
Steel, Paper &
Web Processing
Vertical / gravity
4] General spec.
Impact/Inertia
In-line
Interlocking
2] Target application
Metal
Fan, Pump &
processing,
Blower
textile &
packaging
NEW STANDARD AC DRIVE
Diseño de la carcasa
S100
1] LV Drive Line-up
550mm
2] Target application
3] Fame design
4] General spec.
128mm
5] Features
6] Option
7] Comparison
0.4~4kW
5.5~22kW
30~75kW
256.6mm
460mm
8] Launching schedule
0.4~22kW
3/32
NEW STANDARD AC DRIVE
Especificaciones generales
S100
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
• Capacidad del modelo
- 200V, Single-phase, 0.4~2.2kW(2.5~11A, HD)
- 200V, Three-phase, 0.4~15kW(2~55.9A, HD)
- 400V, Three-phase, 0.4~75kW(1.8~152A, HD)
• Capacidad de sobrecarga (rango dual)
- 150% for 60sec. (Heavy Duty)
- 120% for 60sec. (Normal Duty)
• Rangos de voltajes de entrada
- 200~240V Single/Three-phase (-15%/+10%)
- 380~480V Three-phase (-15%/+10%)
• Métodos de control
- V/f, Sensorless vector, PM Sensorless(customized)
• Salida de frecuencia
- 0~400Hz (Sensorless: 0~120Hz)
• Frecuencia de portadora
- Heavy Duty: 1~15kHz / Normal Duty: 1~5kHz
• Grado de protección
- Standard: IP20, Optional: NEMA1/NEMA4X(IP66)
• Certificaciones globales
- CE, UL, cUL, RoHS
Inbuilt EMC Filter, DC Reactor, LCD Keypad
6] Option
IP20 400V/3Φ
7] Comparison
8] Launching schedule
Inbuilt EMC Filter, LED keypad
IP20 400V/3Φ (C3)
IP20 200V/1Φ (C2)
Inbuilt LED Keypad
IP20 400V/3Φ
IP20 200V/3Φ
IP20 200V/1Φ
Inbuilt EMC Filter, LED keypad, Discharge switch(IP66, NEMA4X)
IP66 400V/3Φ
IP66 200V/3Φ
4/32
0.4
0.75
1.5
2.2
3.7 4.0
5.5
7.5
11
15
18.5
22
30
37
55
75
kW
NEW STANDARD AC DRIVE
S100
1] LV Drive Line-up
Especificaciones generales
Drive capacity(kW)
0.4~4kW
5.5~22KW
30~75kW
2] Target application
3] Fame design
Diseño
4] General spec.
5] Features
6] Option
7] Comparison
Control terminal I/O
8] Launching schedule Keypad
Inbuilt comm.
Standard I/O: 27pins(3.5mm pitch, three-stage)
2nd I/O: 23pins(5mm pitch, three-stage)
27pins(5mm pitch, two-stage)
Inbuilt 7 segment keypad as standard
(Graphic LCD keypad as external option)
Inbuilt Graphic LCD keypad as standard
Inbuilt in RS485(Modbus RTU / LS Bus) as standard (Max. speed 115kbps)
CANopen, Profibus DP, Ethernet(Modbus TCP / Ethernet I/P)
Optional Comm.
EMC Filter
Inbuilt EMC filter
as option:
200V/1Φ(C2)
400V/3Φ(C3)
Inbuilt DC reactor as standard
Inbuilt Dynamic braking transistor as standard
N/A
Side by Side (2mm)
N/A (50mm)
External option installation type
Internal option installation type
Side by Side
(Zero stack)
Communication option
installation
5/32
Top ventilation cover
Inbuilt EMC filter as option:
400V/3Φ(C3)
N/A
DC Reactor
Dynamic Braking
Transistor
Inbuilt EMC filter as
standard:
400V/3Φ(C3)
Open
Close
NEW STANDARD AC DRIVE
S100
General specifications
7 segmentos (0.4~22kW)
1] LV Drive Line-up
LCD Gráfica (30~75kW)
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
6/32
Display
• 7-Segments, 4 Digit
Display
• Graphic LCD (128x64 Pixels)
LED
•4
LED
•3
Key
• 8 key
- 4 directions
- Run
- Stop / Reset
- Enter (SET)
- ESC*
Key
• 11 key
- 4 directions
- Mode
- Stop / Reset
- FWD / REV
- ESC / MULTI*
- PROG ENT
NEW STANDARD AC DRIVE
S100
Especificaciones generales
No. of Pins
Standard
I/O
(0.4~22kW)
27 pins
Standard
I/O
(30~75kW)
27 pins
Fault relay output
A1,B1,C1
A1,B1,C1
A1,B1,C1
24V output
24
24
24
Analog input voltage (+12V)
VR
VR
VR
Analog voltage input
V1
V1
V1
Analog voltage/Current input
I2
I2
I2
Analog voltage/Current output
AO
AO1
AO
Analog voltage output
-
AO2
-
RS485 signal / Ground
S+,S- / SG
S+,S- / SG
S+,S- / SG
Safety input
SA,SB,SC
SA,SB,SC
I/O Ground(Except for comm.)
CM
CM
CM
Multifunctional TR output
Q1,EG
Q1,EG
Q1,EG
Multifunctional digital input
(PNP/NPN)
P1~P7
P1~P7
P1~P5
Pulse train input(0~32kHz)
TI
TI
P5(Common)
Pulse train output(0~32kHz)
TO
TO
Q1(Common)
Terminal pitch
3.5mm
5mm
5mm
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
7/32
2nd I/O
(0.4~22kW)
23 pins
SA,SB,SC
NEW STANDARD AC DRIVE
S100
Especificaciones generales
FWD
Turn on in FWD operation, Flash in Acc./Dec.
REV
Turn on in REV operation, Flash in Acc./Dec.
1] LV Drive Line-up
RUN
Turn on in operation
2] Target application
SET
Turn on when user setting,
Flash when ESC is used as Multi-function Key
3] Fame design
7-Segment
Status & Parameter Information
4] General spec.
STOP
RESET
RUN
5] Features
ESC
ENT
6] Option
7] Comparison
8] Launching schedule
ON
SW4
CN4
OFF
PNP NPN IO VO
SW1
SW3
V
I
SW2
CN2
8/32
Flash in
trip
mode
RUN
Run command
STOP/RESET
STOP : Stop command, RESET : Reset command

Up
Moving code / Increase parameter value

Down
Moving code / Decrease parameter value

Left
Moving group / Moving cursor to left

Right
Moving group / Moving cursor to right
ENT
Enter
Changing parameter / Saving parameter
ESC
Multi-key
JOG / Remote-Local / Cancel
Switch Position
LEFT
RIGHT
SW1
NPN / PNP
PNP
NPN
SW2
Analog Input Select
SW3
Analog Output Select
SW4
Terminal Resistor
CN2
Graphic LCD Port
Port for connecting iS7 Keypad
CN4
Field bus Port
CANopen, Ethernet/IP, Profibus-DP
Current
Voltage
ON
OFF
UP
DOWN
Voltage
Current
NEW STANDARD AC DRIVE
General specifications
S100
1] LV Drive Line-up
2] Target application
3] Fame design
iS7 Normal Cable
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
1
1
[RJ45 to 9 Pin Cable]
9/32
2
2
[9 Pin to USB Converter]
NEW STANDARD AC DRIVE
S100
General specifications
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
Filtro EMC
- Integrado C3 or C2
Ventiladores
- Tipo succión
- Ventiladores fácil de quitar
5] Features
6] Option
7] Comparison
8] Launching schedule
Disipador de calor
- Tamaño reducido
Soporte para cableado
- Guía para cableado
Banco de capacitores
- Larga duración
10/32
NEW STANDARD AC DRIVE
S100
Características (rendimiento)
1] LV Drive Line-up
2] Target application
Dual CPU Topology
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
I/O MCU*
Main DSP*
11/32
Speed
60MIPS*
Memory
System
Clock
Flash: 256kByte
RAM: 36kByte
Memory
• DSP: Digital Signal Processor
• MIPS: million Instructions Per Second
48Mhz
Flash: 32kByte
RAM: 16kByte
•MCU: Micro Controller Unit
NEW STANDARD AC DRIVE
S100
Características (rendimiento)
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
Torque characteristics
5] Features
6] Option
7] Comparison
8] Launching schedule
12/32
• Test drive: S100 7.5kW 400V class , heavy duty, at rotating Auto-tuning
• Test motor: Heigen induction motor 7.5kW, 3-phase, 4 poles,
NEW STANDARD AC DRIVE
S100
Características (rendimiento)
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
Effect of
Terminal
resistor
13/32
NEW STANDARD AC DRIVE
S100
Características (rendimiento)
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
Flying start(Speed search) realiza suaves reestablecimiento sintonizando la velocidad en vuelo
del motor
14/32
NEW STANDARD AC DRIVE
S100
Características (Ahorro de espacio)
El mejor en tamaño compacto
1] LV Drive Line-up
2] Target application
Instalación lado a lado (Zero stack)
70mm
iG5A
70mm
S100
3] Fame design
50mm
50mm
50mm
50mm
290mm
4] General spec.
5] Features
6] Option
410mm
7] Comparison
68mm
8] Launching schedule
180mm
* Size comparison between S100 and
previous model based on 11kW 400V class
Aproximadamente
60% más pequeño
15/32
70mm
68mm
68mm
30mm
30mm
2mm
2mm
268mm
142mm
NEW STANDARD AC DRIVE
S100
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
16/32
Características (confiabilidad)
NEW STANDARD AC DRIVE
S100
Características (confiabilidad)
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
Code
17/32
Display
Range
Unit
Default
PRT-86
Fan Time Perc
(Read Only)
%
0
PRT-87
Fan Exchange
0.0 ~ 100.0
%
90.0
PRT-88
Fan Time Rst
0 : No
1 : Yes
-
0 (No)
OUT-74
Relay 2
38 : Fan Exchange
-
14 : Run
CNF-74
Fan Time
(Read Only)
-
-
1) PRT-86 : Actual counted value of use (50000hrs = 100%)
2) PRT-87 : Value to exchange the fan (Fan Diagnosis not activated when it is set to 0)
3) PRT-88 : Initializing running time of the fan
NEW STANDARD AC DRIVE
S100
Características (confiabilidad)
[Description of the related parameters]
1] LV Drive Line-up
1) PRT-82 : Percentage of test current
(100% = Rated current of INV CT)
2) PRT-83~85 are displayed when PRT-82 is not set to 0
3) PRT-83
a) CAP Diag 1 : Measuring initial value of Capacitance
b) CAP Diag 2 : Measuring current Capacitance based
on the operation
c) CAP Init : Initializing the measured capacitance
4) PRT-84 : Initial capacitance
It is the Reference value for exchange
5) PRT-85 : Current Capacitance
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
Code
PRT-82
18/32
Display
Range
Unit
Default
CAP Diag Perc
0 / 10 ~100
%
0
PRT-83
CAP Diag
0
1
2
3
-
0 : None
PRT-84
CAP Level 1
0.0 / 50.0 ~ 95.0
%
-
PRT-85
CAP Level 2
-
%
-
OUT-32
Relay 2
37 : Cap Warning
:
:
:
:
None
CAP Diag 1
CAP Diag 2
CAP Init
NEW STANDARD AC DRIVE
S100
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
19/32
Características (confiabilidad)
NEW STANDARD AC DRIVE
S100
Características (conveniencia de usuario)
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
Master
Slave 1
Slave 2
Slave 2
•••
RS485 communication
20/32
*LCD keypad of S100 is the same as IS7’s one. It is a external option for S100 0.4~22kW, but is inbuilt for
30~75kW.
NEW STANDARD AC DRIVE
S100
Características (conveniencia de usuario)
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
Inbuilt RS485
communication
7] Comparison
8] Launching schedule
Master
21/32
Slave
NEW STANDARD AC DRIVE
S100
Características (conveniencia de usuario)
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
Control
Circuit
8] Launching schedule
Gate Block
M
Esta función cumple la normativa EN60204-1, stop category 0 (Paro por corte de energía a su
salida). Esta diseñado para cumplir los requerimientos de la EN954-1, Safety Category 3 y
EN61508, SIL2 y EN ISO 13849-1 PL d. quitando el voltaje en los terminales SA, SB activa el
corte de energía en la salida, esto significa que la salida de los IGBTs es cortada
completamente.
22/32
* Note : Output is cut in less than 1ms (SA is activated) or 20ms (SB is activated), but general response time is
1ms (SA and SB are activated coincidently.
NEW STANDARD AC DRIVE
S100
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
23/32
Características (conveniencia de usuario)
NEW STANDARD AC DRIVE
S100
Características (conveniencia de usuario)
1] LV Drive Line-up
2] Target application
Inverter
Controller
Synchronizing
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
Normal
LAN cable
[Características]
• Guarda 1 firmware a descargar
• Guarda 4 grupos de parámetros
• Batería integrada
(80 veces para descargar firmware)
(1000 veces descarga de parámetros)
[Smart Copier]
24/32
NEW STANDARD AC DRIVE
S100
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
25/32
Características (conveniencia de usuario)
NEW STANDARD AC DRIVE
S100
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
26/32
Opciones
NEW STANDARD AC DRIVE
S100
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
27/32
Opciones
NEW STANDARD AC DRIVE
S100
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
28/32
Opciones
NEW STANDARD AC DRIVE
S100
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
29/32
Opciones
NEW STANDARD AC DRIVE
S100
1] LV Drive Line-up
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
8] Launching schedule
30/32
Opciones
NEW STANDARD AC DRIVE
S100
Comparativo
Competitor
(Series)
1] LV Drive Line-up
Yaskawa
(V1000)
Mitsubishi
(E700)
ABB
(ACS355)
Danfoss
(FC51)
LSIS
(S100)
0.1~3.7KW
0.1~15KW
0.2~15KW
Semi
0.1~2.2KW
0.1~15KW
0.4~15KW
No
0.37~2.2KW
0.37~11KW
0.37~22KW
No
0.18~2.2KW
0.18~3.7KW
0.18~22KW
No
0.4~2.2KW
0.4~15KW
0.4~75KW
Semi
Category 3
(External Option)
Category 3
(External Option)
Category 3
(Built-in)
Category 1/2
(Built-in)
Category 2/3
(Built-in or External)
STO, SIL2
X
STO, SIL3
X
STO, SIL2
IP20/IP40
IP20/UL Open
NEMA1/
IP66/67/NEMA4X
(~7.5kW)
IP20
IP21/NEMA 1
IP20/UL Open
NEMA1/
IP66/NEMA4X
(~22kW)
-10~50°C
-10~40°C
50°C:10% Derating
50°C
(40°C : 24hr.)
-10~50°C
(Heavy Duty)
-10~40°C
(Normal Duty)
X
Yes
Smart Logic
Yes
Built-in 0.4~15KW
Built-in as standard
Built-in 1.5~22KW
Built-in as standard
up to 22kW
V/f, SLV 1,2
V/f, SLV, SV
V/f, SLV
V/f, SLV(IM) / SLV(PM)
Appearance
2] Target application
3] Fame design
4] General spec.
5] Features
6] Option
7] Comparison
1Ф 200V class
3Ф 200V class
3Ф 400V class
Dual rating
EMC filter
Machinery
Directive(Safety)
8] Launching schedule
Enclosure
Temperature
User sequence
(Simple PLC)
IP20
NEMA1
IP66/NEMA4X
-10~50°C
(Open Chasis)
40°C:10% Derating
(NEMA1)
Yes
Braking chopper Built-in as standard
Control Mode
Fieldbus
31/32
V/f, SLV(IM) / SLV(PM)
Modbus RTU,
Modbus RTU,
Mechatrolink-II, CCProfibus DP,
CC-Link, DeviceNet,
Link, DeviceNet,
DeviceNet, CANopen,
Profibus DP,
Profibus DP,
Modbus, Ethernet
LonWorks
CANopen, LonWorks
Modbus RTU
Modbus RTU,
Profibus-DP,
CANopen, Ethernet
NEW STANDARD AC DRIVE
S100
1. Line up
Lanzamiento
1] LV Drive Line-up
2] Target application
’14.07
3] Fame design
4] General spec.
’14.07
5] Features
6] Option
7] Comparison
8] Launching schedule
’14.08
’14.07
’14.09
32/32
Related documents