Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
NEW STANDARD AC DRIVE NEW STANDARD AC DRIVE S100 1] LV Drive Line-up 2] Target application LV Drive Line-up Línea Starvert vigente Futura línea de drivers LS Performance • Variador para elevadores L100 (5.5~22kW) 3] Fame design 4] General spec. 5] Features 6] Option iV5 (2.2~800kW) • Alto rendimiento 7] Comparison 8] Launching schedule • Variador premiun • Variador vector type X100 (0.75~800kW) iS7 (0.75~375kW) • Ventilación y bombeo iP5A (5.5~450kW) • Variador HVAC H100 S100 (0.4~75kW) (5.5~800kW) • Variador estándar • Alto rendimiento compacto iG5A (0.4~22kW) iC5 /iE5 (0.1~2.2kW) 1/32 • Clase económica Capacity(kW) C100 /E100 (0.1~7.5kW) • Compactos y económicos Capacity(kW) NEW STANDARD AC DRIVE S100 Aplicaciones objetivo Dificultad técnica 1] LV Drive Line-up 3] Fame design 5] Features 6] Option Heavy Duty applications Press, Winding & Cart S100 Target areas 2/32 Crane, Hoist & E/L Rotation / Fluid 8] Launching schedule Normal Duty applications Horizontal / Friction 7] Comparison Steel, Paper & Web Processing Vertical / gravity 4] General spec. Impact/Inertia In-line Interlocking 2] Target application Metal Fan, Pump & processing, Blower textile & packaging NEW STANDARD AC DRIVE Diseño de la carcasa S100 1] LV Drive Line-up 550mm 2] Target application 3] Fame design 4] General spec. 128mm 5] Features 6] Option 7] Comparison 0.4~4kW 5.5~22kW 30~75kW 256.6mm 460mm 8] Launching schedule 0.4~22kW 3/32 NEW STANDARD AC DRIVE Especificaciones generales S100 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features • Capacidad del modelo - 200V, Single-phase, 0.4~2.2kW(2.5~11A, HD) - 200V, Three-phase, 0.4~15kW(2~55.9A, HD) - 400V, Three-phase, 0.4~75kW(1.8~152A, HD) • Capacidad de sobrecarga (rango dual) - 150% for 60sec. (Heavy Duty) - 120% for 60sec. (Normal Duty) • Rangos de voltajes de entrada - 200~240V Single/Three-phase (-15%/+10%) - 380~480V Three-phase (-15%/+10%) • Métodos de control - V/f, Sensorless vector, PM Sensorless(customized) • Salida de frecuencia - 0~400Hz (Sensorless: 0~120Hz) • Frecuencia de portadora - Heavy Duty: 1~15kHz / Normal Duty: 1~5kHz • Grado de protección - Standard: IP20, Optional: NEMA1/NEMA4X(IP66) • Certificaciones globales - CE, UL, cUL, RoHS Inbuilt EMC Filter, DC Reactor, LCD Keypad 6] Option IP20 400V/3Φ 7] Comparison 8] Launching schedule Inbuilt EMC Filter, LED keypad IP20 400V/3Φ (C3) IP20 200V/1Φ (C2) Inbuilt LED Keypad IP20 400V/3Φ IP20 200V/3Φ IP20 200V/1Φ Inbuilt EMC Filter, LED keypad, Discharge switch(IP66, NEMA4X) IP66 400V/3Φ IP66 200V/3Φ 4/32 0.4 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11 15 18.5 22 30 37 55 75 kW NEW STANDARD AC DRIVE S100 1] LV Drive Line-up Especificaciones generales Drive capacity(kW) 0.4~4kW 5.5~22KW 30~75kW 2] Target application 3] Fame design Diseño 4] General spec. 5] Features 6] Option 7] Comparison Control terminal I/O 8] Launching schedule Keypad Inbuilt comm. Standard I/O: 27pins(3.5mm pitch, three-stage) 2nd I/O: 23pins(5mm pitch, three-stage) 27pins(5mm pitch, two-stage) Inbuilt 7 segment keypad as standard (Graphic LCD keypad as external option) Inbuilt Graphic LCD keypad as standard Inbuilt in RS485(Modbus RTU / LS Bus) as standard (Max. speed 115kbps) CANopen, Profibus DP, Ethernet(Modbus TCP / Ethernet I/P) Optional Comm. EMC Filter Inbuilt EMC filter as option: 200V/1Φ(C2) 400V/3Φ(C3) Inbuilt DC reactor as standard Inbuilt Dynamic braking transistor as standard N/A Side by Side (2mm) N/A (50mm) External option installation type Internal option installation type Side by Side (Zero stack) Communication option installation 5/32 Top ventilation cover Inbuilt EMC filter as option: 400V/3Φ(C3) N/A DC Reactor Dynamic Braking Transistor Inbuilt EMC filter as standard: 400V/3Φ(C3) Open Close NEW STANDARD AC DRIVE S100 General specifications 7 segmentos (0.4~22kW) 1] LV Drive Line-up LCD Gráfica (30~75kW) 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 6/32 Display • 7-Segments, 4 Digit Display • Graphic LCD (128x64 Pixels) LED •4 LED •3 Key • 8 key - 4 directions - Run - Stop / Reset - Enter (SET) - ESC* Key • 11 key - 4 directions - Mode - Stop / Reset - FWD / REV - ESC / MULTI* - PROG ENT NEW STANDARD AC DRIVE S100 Especificaciones generales No. of Pins Standard I/O (0.4~22kW) 27 pins Standard I/O (30~75kW) 27 pins Fault relay output A1,B1,C1 A1,B1,C1 A1,B1,C1 24V output 24 24 24 Analog input voltage (+12V) VR VR VR Analog voltage input V1 V1 V1 Analog voltage/Current input I2 I2 I2 Analog voltage/Current output AO AO1 AO Analog voltage output - AO2 - RS485 signal / Ground S+,S- / SG S+,S- / SG S+,S- / SG Safety input SA,SB,SC SA,SB,SC I/O Ground(Except for comm.) CM CM CM Multifunctional TR output Q1,EG Q1,EG Q1,EG Multifunctional digital input (PNP/NPN) P1~P7 P1~P7 P1~P5 Pulse train input(0~32kHz) TI TI P5(Common) Pulse train output(0~32kHz) TO TO Q1(Common) Terminal pitch 3.5mm 5mm 5mm 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 7/32 2nd I/O (0.4~22kW) 23 pins SA,SB,SC NEW STANDARD AC DRIVE S100 Especificaciones generales FWD Turn on in FWD operation, Flash in Acc./Dec. REV Turn on in REV operation, Flash in Acc./Dec. 1] LV Drive Line-up RUN Turn on in operation 2] Target application SET Turn on when user setting, Flash when ESC is used as Multi-function Key 3] Fame design 7-Segment Status & Parameter Information 4] General spec. STOP RESET RUN 5] Features ESC ENT 6] Option 7] Comparison 8] Launching schedule ON SW4 CN4 OFF PNP NPN IO VO SW1 SW3 V I SW2 CN2 8/32 Flash in trip mode RUN Run command STOP/RESET STOP : Stop command, RESET : Reset command Up Moving code / Increase parameter value Down Moving code / Decrease parameter value Left Moving group / Moving cursor to left Right Moving group / Moving cursor to right ENT Enter Changing parameter / Saving parameter ESC Multi-key JOG / Remote-Local / Cancel Switch Position LEFT RIGHT SW1 NPN / PNP PNP NPN SW2 Analog Input Select SW3 Analog Output Select SW4 Terminal Resistor CN2 Graphic LCD Port Port for connecting iS7 Keypad CN4 Field bus Port CANopen, Ethernet/IP, Profibus-DP Current Voltage ON OFF UP DOWN Voltage Current NEW STANDARD AC DRIVE General specifications S100 1] LV Drive Line-up 2] Target application 3] Fame design iS7 Normal Cable 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 1 1 [RJ45 to 9 Pin Cable] 9/32 2 2 [9 Pin to USB Converter] NEW STANDARD AC DRIVE S100 General specifications 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. Filtro EMC - Integrado C3 or C2 Ventiladores - Tipo succión - Ventiladores fácil de quitar 5] Features 6] Option 7] Comparison 8] Launching schedule Disipador de calor - Tamaño reducido Soporte para cableado - Guía para cableado Banco de capacitores - Larga duración 10/32 NEW STANDARD AC DRIVE S100 Características (rendimiento) 1] LV Drive Line-up 2] Target application Dual CPU Topology 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule I/O MCU* Main DSP* 11/32 Speed 60MIPS* Memory System Clock Flash: 256kByte RAM: 36kByte Memory • DSP: Digital Signal Processor • MIPS: million Instructions Per Second 48Mhz Flash: 32kByte RAM: 16kByte •MCU: Micro Controller Unit NEW STANDARD AC DRIVE S100 Características (rendimiento) 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. Torque characteristics 5] Features 6] Option 7] Comparison 8] Launching schedule 12/32 • Test drive: S100 7.5kW 400V class , heavy duty, at rotating Auto-tuning • Test motor: Heigen induction motor 7.5kW, 3-phase, 4 poles, NEW STANDARD AC DRIVE S100 Características (rendimiento) 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule Effect of Terminal resistor 13/32 NEW STANDARD AC DRIVE S100 Características (rendimiento) 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule Flying start(Speed search) realiza suaves reestablecimiento sintonizando la velocidad en vuelo del motor 14/32 NEW STANDARD AC DRIVE S100 Características (Ahorro de espacio) El mejor en tamaño compacto 1] LV Drive Line-up 2] Target application Instalación lado a lado (Zero stack) 70mm iG5A 70mm S100 3] Fame design 50mm 50mm 50mm 50mm 290mm 4] General spec. 5] Features 6] Option 410mm 7] Comparison 68mm 8] Launching schedule 180mm * Size comparison between S100 and previous model based on 11kW 400V class Aproximadamente 60% más pequeño 15/32 70mm 68mm 68mm 30mm 30mm 2mm 2mm 268mm 142mm NEW STANDARD AC DRIVE S100 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 16/32 Características (confiabilidad) NEW STANDARD AC DRIVE S100 Características (confiabilidad) 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule Code 17/32 Display Range Unit Default PRT-86 Fan Time Perc (Read Only) % 0 PRT-87 Fan Exchange 0.0 ~ 100.0 % 90.0 PRT-88 Fan Time Rst 0 : No 1 : Yes - 0 (No) OUT-74 Relay 2 38 : Fan Exchange - 14 : Run CNF-74 Fan Time (Read Only) - - 1) PRT-86 : Actual counted value of use (50000hrs = 100%) 2) PRT-87 : Value to exchange the fan (Fan Diagnosis not activated when it is set to 0) 3) PRT-88 : Initializing running time of the fan NEW STANDARD AC DRIVE S100 Características (confiabilidad) [Description of the related parameters] 1] LV Drive Line-up 1) PRT-82 : Percentage of test current (100% = Rated current of INV CT) 2) PRT-83~85 are displayed when PRT-82 is not set to 0 3) PRT-83 a) CAP Diag 1 : Measuring initial value of Capacitance b) CAP Diag 2 : Measuring current Capacitance based on the operation c) CAP Init : Initializing the measured capacitance 4) PRT-84 : Initial capacitance It is the Reference value for exchange 5) PRT-85 : Current Capacitance 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule Code PRT-82 18/32 Display Range Unit Default CAP Diag Perc 0 / 10 ~100 % 0 PRT-83 CAP Diag 0 1 2 3 - 0 : None PRT-84 CAP Level 1 0.0 / 50.0 ~ 95.0 % - PRT-85 CAP Level 2 - % - OUT-32 Relay 2 37 : Cap Warning : : : : None CAP Diag 1 CAP Diag 2 CAP Init NEW STANDARD AC DRIVE S100 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 19/32 Características (confiabilidad) NEW STANDARD AC DRIVE S100 Características (conveniencia de usuario) 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule Master Slave 1 Slave 2 Slave 2 ••• RS485 communication 20/32 *LCD keypad of S100 is the same as IS7’s one. It is a external option for S100 0.4~22kW, but is inbuilt for 30~75kW. NEW STANDARD AC DRIVE S100 Características (conveniencia de usuario) 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option Inbuilt RS485 communication 7] Comparison 8] Launching schedule Master 21/32 Slave NEW STANDARD AC DRIVE S100 Características (conveniencia de usuario) 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison Control Circuit 8] Launching schedule Gate Block M Esta función cumple la normativa EN60204-1, stop category 0 (Paro por corte de energía a su salida). Esta diseñado para cumplir los requerimientos de la EN954-1, Safety Category 3 y EN61508, SIL2 y EN ISO 13849-1 PL d. quitando el voltaje en los terminales SA, SB activa el corte de energía en la salida, esto significa que la salida de los IGBTs es cortada completamente. 22/32 * Note : Output is cut in less than 1ms (SA is activated) or 20ms (SB is activated), but general response time is 1ms (SA and SB are activated coincidently. NEW STANDARD AC DRIVE S100 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 23/32 Características (conveniencia de usuario) NEW STANDARD AC DRIVE S100 Características (conveniencia de usuario) 1] LV Drive Line-up 2] Target application Inverter Controller Synchronizing 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule Normal LAN cable [Características] • Guarda 1 firmware a descargar • Guarda 4 grupos de parámetros • Batería integrada (80 veces para descargar firmware) (1000 veces descarga de parámetros) [Smart Copier] 24/32 NEW STANDARD AC DRIVE S100 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 25/32 Características (conveniencia de usuario) NEW STANDARD AC DRIVE S100 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 26/32 Opciones NEW STANDARD AC DRIVE S100 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 27/32 Opciones NEW STANDARD AC DRIVE S100 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 28/32 Opciones NEW STANDARD AC DRIVE S100 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 29/32 Opciones NEW STANDARD AC DRIVE S100 1] LV Drive Line-up 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 8] Launching schedule 30/32 Opciones NEW STANDARD AC DRIVE S100 Comparativo Competitor (Series) 1] LV Drive Line-up Yaskawa (V1000) Mitsubishi (E700) ABB (ACS355) Danfoss (FC51) LSIS (S100) 0.1~3.7KW 0.1~15KW 0.2~15KW Semi 0.1~2.2KW 0.1~15KW 0.4~15KW No 0.37~2.2KW 0.37~11KW 0.37~22KW No 0.18~2.2KW 0.18~3.7KW 0.18~22KW No 0.4~2.2KW 0.4~15KW 0.4~75KW Semi Category 3 (External Option) Category 3 (External Option) Category 3 (Built-in) Category 1/2 (Built-in) Category 2/3 (Built-in or External) STO, SIL2 X STO, SIL3 X STO, SIL2 IP20/IP40 IP20/UL Open NEMA1/ IP66/67/NEMA4X (~7.5kW) IP20 IP21/NEMA 1 IP20/UL Open NEMA1/ IP66/NEMA4X (~22kW) -10~50°C -10~40°C 50°C:10% Derating 50°C (40°C : 24hr.) -10~50°C (Heavy Duty) -10~40°C (Normal Duty) X Yes Smart Logic Yes Built-in 0.4~15KW Built-in as standard Built-in 1.5~22KW Built-in as standard up to 22kW V/f, SLV 1,2 V/f, SLV, SV V/f, SLV V/f, SLV(IM) / SLV(PM) Appearance 2] Target application 3] Fame design 4] General spec. 5] Features 6] Option 7] Comparison 1Ф 200V class 3Ф 200V class 3Ф 400V class Dual rating EMC filter Machinery Directive(Safety) 8] Launching schedule Enclosure Temperature User sequence (Simple PLC) IP20 NEMA1 IP66/NEMA4X -10~50°C (Open Chasis) 40°C:10% Derating (NEMA1) Yes Braking chopper Built-in as standard Control Mode Fieldbus 31/32 V/f, SLV(IM) / SLV(PM) Modbus RTU, Modbus RTU, Mechatrolink-II, CCProfibus DP, CC-Link, DeviceNet, Link, DeviceNet, DeviceNet, CANopen, Profibus DP, Profibus DP, Modbus, Ethernet LonWorks CANopen, LonWorks Modbus RTU Modbus RTU, Profibus-DP, CANopen, Ethernet NEW STANDARD AC DRIVE S100 1. Line up Lanzamiento 1] LV Drive Line-up 2] Target application ’14.07 3] Fame design 4] General spec. ’14.07 5] Features 6] Option 7] Comparison 8] Launching schedule ’14.08 ’14.07 ’14.09 32/32