Segment Design Tool
The Segment Design Tool (SDT) is specifically designed to verify physical limitations of a FOUNDATION™ fieldbus
Segment, operating under an H1 Card on an Emerson Process Management DeltaV™ Controller.
Note. This tool is not supported on Servers.
New In Release 6.0.1
Issue Resolved:
1. Revisions were not shown correctly for Honeywell ST700 Pressure Transmitter for different segment types.
Known Errata / Limitations:
1. Certification of the Field Devices with respect to the segment type is not correct.
Example:
For an Entity Segment created from a Blank Template, the certification for field devices is shown as NON-IS,
even if ENTITY certification is available for the device.
2. Support for multiple certifications for Power Conditioners.
Example:
For MTL-Relcom power conditioners, F101-P* and F102-P* there are two certifications NON-IS and Entity.
New In Release 6.0.0
Main objective of this release is to implement the heuristic evaluation comments given by the Human Centered
Design Team who had conducted the heuristic usability evaluation review for Segment Design Tool.
1) Property Window Panel Requirement.
A common property window panel shows the properties for components like H1 Cards, Connectors,
Segments, Power Conditioners, Cables, Cable Types and Devices.
2) Registration page modified.
Fax number label and text box removed from the registration web page.
3) “Go to” feature is added above the components tree view (since they are related) and removed from the
toolbar.
4) Excel Icon changed on toolbar.
5) No double clicking option available to display properties for components. Single click on the component
present on the segment editor to view its property on the property window panel (except for Cable Type
properties which open on a single click on the cables in the components tree view).
6) Obsolete mark shown on the description for components which are obsolete.
Below components are marked as obsolete:
 5300 Coriolis Meter
 4081FG Flue Gas Transmitter
 4081C/T Conductivity Transmitter
 4081pH Transmitter
Below components are not obsolete:
 700XA Gas Chromatograph


1500XA Gas Chromatograph
OCX 8800 Oxygen and Combustible Gas Analyzer
7) Description added for segment types on opening a blank segment.
8) Description added for View properties dialog.
9) Consistency in showing user message for example: messages should be different for Format Error, Missing
Value and Input Data Error.
10) Remove tabs from the form wherever it is not required.
11) “Apply” button is not required on forms.
12) Save message modified to “Please save your changes to continue”.
13) Help file and manual updated.
14) Added 18 devices to the SDT Component Library.
Bug fixes:
1. When we create a large segment on the segment design area and generate HTML report for it, the snapshot
shown in the HTML report does not capture the whole segment.
2. Copy Segment feature copies the tags of the components which is incorrect. There cannot be two
components with same tag.
3. For 8800 Vortex Flow Meter, model number shown is “8800” which needs to be modified as “8800D”.
New In Release 5.4.0
Main objective of this release is :
1) To decouple the library components from the main setup (main application) of SDT to ease the process of
library update in the future without impacting the main application.
2) To update the library for DeltaV approved passive components as per Device install Kits.

Segment Design Tool Component Library is decoupled from Segment Design Tool Main setup. By this the
release management of the library components will be more efficient and also will have the advantage
of any change in the library components list will not impact the main SDT application.

Given Support for DeltaV approved passive components registered under Device install kits.

Given Support to Windows 7 Chinese Operating System.

Major Bug Fixes
-
Tool was not working properly for Non-Admin user.
-
Draging S-Series H1 card on to design area gave an error.
-
Fail to drag new component on design area.
-
Renaming a Segment Component while in the tree view gave an error.
New In Release 5.3.0

Given Support to Windows 7.

Given support for both Simplex and Redundant H1 cards of S series with Integrated Power Supply.

Given support for below devices

2700FF Coriolis Flow Meter (Micro Motion)

8732F Rosemount Magnetic Flow (Rosemount Inc.)

Prosonic Flow 92 Ultrosonic Flow Meter (Endress+Hauser)

700XA Gas Chromatograph (Rosemount Analytical)

TopWorx D2-FF Discrete Valve Controller (Topworx Inc)

MT5000 Guided Wave Radar (KTEK)

3051S Pressure Transmitter (Rosemount Inc)

DLC3020F Fieldbus Level controller/Transmitter (Fisher)

Flowserve LX3400MD Actuator (Flowserve)

FFX Pressure Transmitter (Dynisco Instruments)

Polytron 7000FB Modular fixed intrinsically safe gas detector (Drager)

OCX 8800 Oxyzen and Combustible Gas Analyzer (Rosemount Analytical)

SITRANS LR250 Pulse Radar Level Transmitter (SITRANS)

DY/DYA Vortex Flowmeter (Yokogawa)

YPK110 Fieldbus-to-Pneumatic Converter (Yokogawa)

IM461052A FF I/O Module 2DI, 2DO (StoneL)

IM461054A FF I/O Module 2DI,2DO,1AI,1AO

IM465015A FF I/O Module 2DI,2DO,1AI,1AO (Din Rail) (StoneL)

IM461087A FF I/O Module 2DI,2 (Relay-Independant) DO,1AI, 1AO (StoneL)

IM465022A FF I/O Module 2DI,2 (Relay-Independant) DO,1AI,1AO (Din Rail) (StoneL)

IM461088A FF I/O Module 2DI,2 (Relay-Interlocked) DO,1AI,1AO (StoneL)

IM465023A FF I/O Module 2DI,2 (Relay-Interlocked) DO,1AI,1AO (Din Rail) (StoneL)

4449 ASCO Controls Valve Controller (ASCO Controls)

1500XA Gas Chromatograph (Rosemount Analytical)

Enable Discrete or Analog Foundation Fieldbus Control of EIM DCM Electric Actuator (Microcyber,
Inc.)

9413/21-21*-84-FF Digital I/O Coupler (R STALH)

ES-FF Electronic 2-wire transmitter ES-FF for converting a pointer position into a digital signal
(Heinrichs Messtechnik GmbH)

EJX910A (Yokogawa)

LB491 Density and Concentration Measurement (Berthold Technologies)

LB490 Level Transmitter (Berthold Technologies)

LTM 300FF Magnetostrictive Level Transmitter (ISE-Magtech)

FDVC6200F Fieldbus Digital Valve Actuator (Fisher)

FF700 M700 Module (Mettler Toledo)

O2 4100e FF DO FF Transmitter (Mettler Toledo)

JRBS-49SC-*R 4,6,8,10,12 Port Device Coupler (Turck/InterlinkBT)

JRBS-49TR Fieldbus Terminator (Turck/InterlinkBT)

9412 Series Fieldbus Power Supply Module (R.STAHL Schaltgeraete GmbH)

HCD2-FBPS-1.500 Power Supply, 28-30 Volt (Pepperl+Fuchs)

HCD2-FBPS-1.23.500 Power Supply, 21-23 Volt (Pepperl+Fuchs)

9378-FT Fieldbus Terminator (MTL Instruments)

FS32 Fieldbus Surge Protector (MTL Instruments)

DP-LBF-I1.34 Surge Protector (Pepperl+Fuchs)
New In Release 5.2.1
-Minor Bug Fixes
* Updated calculations for P+F Field Barrier considering open circuit voltage 13V, series resistance 75 ohm and short
circuit current 40mA
* Added KLD2-PC-1.1.IEC Fieldbus Power Supply to component database
New In Release 5.2.0
FUNCTIONALITY
1.
2.
3.
4.
5.
6.
Support for Microsoft Windows Vista
Ability to add user defined Power Conditioner
Ability to search component in the existing segment designs
Segment Checkout Form
Go To Component in the TreeView so as to minimize time in finding components
Improved GUI
New In Release 5.1.1
-Minor Bug Fixes
* Removal of communication current of 10mA
* Power Supply calculations modified for HPT segment
* Modified voltage calculations for the device connected to field barrier on HPT Segment
New In Release 5.1.0
FIELD BARRIERS
- *-FB-Ex4.* Zone 1/Div2 FieldBarrier with 4-spur intrinsically safe outputs
- 9411/21-* Zone 1, 2/Class I, Div 2 FieldBarrier with 4 spur outputs
- 9311-FB-* Zone 1, 2/Class I, Div 2 FieldBarrier with 4 spur outputs
SEGMENT PROTECTORS
- *-JBSC-4.* Zone2/Div2 Segment Protector with 4-spur outputs
- *-JBSC-6.* Zone2/Div2 Segment Protector with 6-spur outputs
- *-JBSC-8.* Zone2/Div2 Segment Protector with 8-spur outputs
- R-SP-N12 Zone2/Div2 Segment Protector with 12-spur outputs
- R-SP-E12 Zone1 Segment Protector with 12-spur outputs
FUNCTIONALITY
1.
2.
Ability to design and validate HPT Segments.
Improved GUI.
New In Release 5.0.0
FIELD DEVICES
1.
Support for the following Beka Associates Devices
2.
- BA488CF Fieldbus Display
- BA414DF Fieldbus Display
Support for the following Yokogawa Devices
3.
- DO202-F Dissolved Oxygen Transmitter
- Rotamass Coriolis Mass Flowmeter
Support for the following Pepperl+Fuchs Devices
4.
- F2D0-TI-Ex8.FF.* Temperature Multiplexer
Support for the following Dynisco Instruments Devices
- FFX Series Pressure Transmitter
HOST
- Ovation H1 Card
- Ovation H1 Redundant Card
POWER SUPPLIES
- F89x Power Supply with F801 Power Module
- F89x Power Supply with F802 Power Module
- 9412/PS-I Redundant Fieldbus Power Supply with Terminator
TERMINATORS
- FBT1-IS Fieldbus IS Terminator
- RSEV 49 TR Eurofast Fieldbus Terminator
FUNCTIONALITY
1.
2.
3.
4.
5.
Interface for adding new cables to the SDT database has been added.
Additional parameters available for Segment design with this version. These include the option for adding Visitor
Device, Spare Field Devices to the Segment, performing SC Check for the Segment and setting the value of Min.
Voltage Threshold for the Segment.
IS certifications for which a field device has been certified are displayed as a tooltip in the components TreeView
and in the Intrinsic Safety tab of the Device Properties dialog.
Power Conditioner Rated Current is displayed in Power Conditioner Properties dialog.
Added a hyperlink to the Registration form that takes the user to the Registration page of the SDT.
New In Release 4.1.3
FIELD DEVICES
1.
2.
3.
4.
Support for the following ABB Devices
- 2600T-263/265 Pressure Transmitter
- 2600T-262/264 Pressure Transmitter
- 2600T-267/269 Pressure Transmitter
- FSM4000 Electromagnetic Flowmeter
- FXE4000 Electromagnetic Flowmeter
- TZIDC-120 Electro-Pneumatic Positioner
Support for the following Anderson Instrument Co. Devices
- FPP Series Pressure Transmitter
- FPT Series Temperature Transmitter
Support for the following CSI Devices
- 9210 Machinery Health Transmitter
Support for the following Endress+Hauser GmbH Devices
- Liquiline M CM42 Conductivity Transmitter
- Liquiline M CM42 pH/ORP Transmitter
- Prowirl72 Vortex Swirl Flowmeter
- Prowirl73 Vortex Swirl Flowmeter
5. Support for the following Fisher Controls Devices
- DVC6000f Digital Valve Controller
6. Support for the following Foxboro Devices
- RTT15-F Intelligent Temperature Transmitter
7. Support for the following Knick Elektronische Messgerate GmbH & Co. Devices
- Stratos 2232X Torodial Conductivity Transmitter
- Stratos FF 2231X Oxygen Transmitter
- Stratos FF 2231X pH Transmitter
8. Support for the following KTEK Corporation Devices
- AT100 Magnetostrictive Level Transmitter
9. Support for the following Magnetrol Devices
- Eclipse 705 Advanced Guided Wave Radar (GWR) Level Transmitter
- Eclipse 705 3x Enhanced Guided Wave Radar (GWR) Level Transmitter
10. Support for the following Metso Devices
- ND9000F Valve controller
11. Support for the following Mettler Toledo GmbH Devices
- 7100e Conductivity Transmitter
- DO 4100e Dissolved Oxygen transmitter
- pH 2100e pH transmitter
12. Support for the following Oval Corporation Devices
- Ex-Delta Vortex Flowmeter
13. Support for the following PR Electronics Devices
- 5350 Temperature Transmitter
- 6350 Temperature Transmitter
14. Support for the following Rosemount Devices
- 752 Fieldbus Remote Display
- 3144 Temperature Transmitter
- 3900 Tank Radar REX Level Transmitter
- 5400 Tank Radar Level Transmitter
- 3095MV Multivariable Transmitter
- 848L Logic Transmitter
- 644 Temperature Transmitter.
15. Support for the following Rosemount Analytical Devices
- 5081A Amperometric Transmitter
- 5000 Oxygen Transmitter
- BINOS 1000 Continuous Gas Analyzer
- MLT 1100 Continuous Gas Analyzer
- XMT Series Fieldbus Transmitter
16. Support for the following Rotork Devices
- FF01 MK2 Valve Positioner
17. Support for the following Samson AG Devices
- 373X-5 Positioner
18. Support for the following Siemens AG Devices
- SIPART-PS2-FF Fieldbus Valve Positioner
- SITRANS P DSIII FF Pressure Transmitter
19. Support for the following El-O-Matic International Devices
- ELQ 22C0 Advanced On/Off Valve Actuator
- ELQ F800 Basic On/Off Valve Actuator
- ELQ 8000 Basic Modulating Valve Actuator
- ELQ A2C0 Pneumatic On/Off Valve Actuator
- ELQ DD30 Advanced Modulating Valve Actuator
20. Support for the following VEGA Grieshaber KG Devices
- Vegabar Pressure Transmitter
- Vegacal Level Transmitter
- Vegaflex Guided microwave Transmitter
- Vegapuls RADAR-level Transmitter
- Vegason Ultrasonic-level Transmitter
21. Support for the following Yokogawa Electric Devices
- AV550G Zirconia Oxygen Analyzer
- ADMAG AXF Magnetic Flowmeter
POWER SUPPLIES
- 9121-IS Fieldbus FISCO Power supply
- 9122-IS Fieldbus FISCO Power supply
- 9111-NI Fieldbus FNICO Power supply
- 9112-NI Fieldbus FNICO Power supply
- HD2-FBPS-1.500 Power Supply Module with MB-FB-1R motherboard
- HD2-FBPS-1.23.500 Power Supply Module with MB-FB-1R motherboard
- HD2-FBPS-1.17.500 Power Supply Module with MB-FB-1R motherboard
- KLD2-FBPS-1.25.360 Fieldbus Power Supply
FIELD CONNECTORS
- FCS-MB10-T 10 Device Connection Megablock with Fixed Terminator
- FCS-MB2-T 2 Device Connection Megablock with Fixed Terminator
- FCS-MB4-T 4 Device Connection Megablock with Fixed Terminator
- FCS-MB8-T 8 Device Connection Megablock with Fixed Terminator
- FCS-MB12-SG-T 12 Device Connection Megablock with SpurGuards & Fixed Terminator
- FCS-MB2-SG-T 2 Device Connection Megablock with SpurGuards & Fixed Terminator
- FCS-MB4-SG-T 4 Device Connection Megablock with SpurGuards & Fixed Terminator
- FCS-MB8-SG-T 8 Device Connection Megablock with SpurGuards & Fixed Terminator
- FCS-MB10-SG-T 10 Device Connection Megablock with SpurGuards & Fixed Terminator
- F118 10 Device Connection Megablock with SpurGuards & Internal Switchable Terminator
- F241 2 Device Connection IS Megablock with SpurGuards
- F245 4 Device Connection IS Megablock with SpurGuards
- F247 4 Device Connection IS Megablock with SpurGuards & Fixed Terminator
- F251 8 Device Connection IS Megablock with SpurGuards
- F253 8 Device Connection IS Megablock with Spur Guards & Fixed Terminator
- F259 10 Device Connection IS Megablock with Spur Guards & Fixed Terminator
- F261 10 Device Connection IS Megablock with SpurGuards & Internal Switchable Terminator
- F245-XE 4 Device Connection ME Megablock with SpurGuards
- F251-XE 8 Device Connection ME Megablock with SpurGuards
- F259-XE 10 Device Connection ME Megablock with SpurGuards & Fixed Terminator
- JBBS-49SC-E813 8 Device Connection Junction Block with Short Circuit Protection
- JBBS-49SC-E613 6 Device Connection Junction Block with Short Circuit Protection
- JBBS-49SC-E413 4 Device Connection Junction Block with Short Circuit Protection
TERMINATORS
- FN-FT-Ex1.D.IEC Fieldbus Terminator (Threaded)
- FN-FT-Ex1.I.IEC Fieldbus IS Terminator (Threaded)
- F100 Fieldbus Terminator with Surge Protection
- FCS-MBT-XE ME Megablock Terminator with Surge Protection
- RSV 49 TR Minifast Fieldbus Terminator
FUNCTIONALITY
1.
Added support for the 3420 Fieldbus Interface Module.
2.
Modified interface for adding new field devices to the SDT field device list. The interface now captures
device certification information and revision information for each certification.
3.
Ability to design and validate FISCO and FNICO Segments.
4.
Improved ENTITY IS design and validation algorithm.
New In Release 3.9.2 (Beta)
1.
3420 Fieldbus Interface Module
FUNCTIONALITY
1.
Added support for the 3420 Fieldbus Interface Module.
New In Release 3.8.1
FIELD DEVICES
1.
Support for the following ABB Devices
* ABB Instrumentation TB82TE
* ABB Instrumentation TB82EC
* ABB Instrumentation TB82pH
2.
Support for the following Fisher Devices
* Fisher DVC5000f AO/PID/IS Digital Valve Controller 5420
3.
Support for the following FlowServe Devices
* FlowServe BuSwitch
* Limitorque MX100 Rev 1
4.
Support for the following Krohne Devices
* Krohne BM100A
* Krohne IFC090
5.
Support for the following Dresser Devices
* Masoneillan Dresser Valve Positioner
6.
Support for the following Rosemount Devices
* Rosemount 5600
7.
Support for the following Rosemount Analytical Devices
* Rosemount Analytical 5081-C
8.
Support for the following Valve Automation Devices
* Valve Automation Pneumatic Actuator D3A0-FieldQ
9.
Support for the following Yamatake Devices
* Yamatake AVP 303 Valve Positioner
* Yamatake Pressure Transmitter DST
* Yamatake Temperature Transmitter ATT
FUNCTIONALITY
1.
Reorganized TreeView layout. Major categories are now System, Host Interface, Physical Layer, and Field
Devices. Individual suppliers are listed under each major category.
2.
An Interface for adding new field devices to the SDT field device list has been added.
3.
Initial segment now includes only H1 card so other power supplies besides MTL can be used.
4.
A Disclaimer has been added on the opening screen releasing Emerson from any liability related to the
segment design.
New In Release 3.7.99
1.
Hawke Route Master 100 Series
* RouteMaster Series 100 IS Power Supply
* 4-Way RouteMaster 114 Device Coupler - IIB
* 8-Way RouteMaster 118 Device Coupler - IIB
2.
Relcom Inc.
* Relcom Redundant Power Supply FPS-I
* Relcom Dual Fieldbus Power Supply FPS-DT
* Relcom FCS-MB2-SG 2 Port MegaBlock with SpurGuard
* Relcom FCS-MB4-SG 4 Port MegaBlock with SpurGuard
* Relcom FCS-MB8-SG 8 Port MegaBlock with SpurGuard
* Relcom FCS-MB2 2 Port MegaBlock
* Relcom FCS-MB4 4 Port MegaBlock
* Relcom FCS-MB8 8 Port MegaBlock
* Relcom Terminator FCS-MBT
3.
MTL
* MTL Terminator FBT-1
4.
SpurGuardTM / Current limiting Bricks
* Will alert user if current limit is exceeded on spur under normal load conditions.
* Will alert user if when shorted a Spur will cause any device to drop off the Segment through low voltage or cause
any Power Conditioner to exceed specified current.
5.
Terminator Devices
* The ability to add terminators as individual devices to support the Relcom FCS-MBT and MTL FBT-1
6.
I.S. Terminators
* The ability to add none, one or two Terminators to an IS Segment with validation depending on the Power
Conditioner type.
New In Release 3.6.90
1.
H1 Redundant Cards
- New Style H1 Cards Power Requirements
- Full Support for Redundancy
2.
Additional Device Support
* Support for the following ABB Devices
- ABB 600T EN Pressure Transmitter
- ABB 2000T Pressure Transmitter
- ABB TRIO_WIRL Vortex/Swirl Flow Meter
- ABB TF02 Temperature Transmitter
* Support for the following Buerkert Werke Devices
* 8643 Power I/O Box
* Support for the following Dresser Devices
* FVP110 Dresser Flow Control
* Support for the following EIM Devices
- EA00 Valve Positioner
- ED00 On/Off Valve
* Support for the following El-O-Matic Devices
- 22C0 ELQ On/Off Advanced
- DD30 ELQ On/Off Advanced
- 8000 ELQ On/Off Basic
- F800 ELQ Positioner Basic
- A2C0 ELQ On/Off Pneumatic
- 0990 ELQ On/Off Extended
- 7360 ELQ Positioner Extended
* Support for the following Endress+Hausser GmbH Devices
- PROMAG53 Electromagnetic Flowmeter
- PROSONIC93 Ultrasonic Flowmeter
- TMT 165 Temperature Transmitter
- CERABAR S Pressure Transmitter
- DELTABAR S Pressure Transmitter
- DELTAPILOT S Radar Level Transmitter
- LEVELFLEX M Radar Level Transmitter
- Promass 83 Coriolis Flow Meter
- Micropilot II Radar Level Meter
- Micropilot M Radar Level Meter
* Support for the following Fisher Controls Devices
- DVC5000f AO/PID/IS Digital Valve Controller
- DVC5000f DI/DO Digital Valve Controller
* Support for the following Fisher Rosemount Systems Devices
- VE4052 H1 Carrier
* Support for the following Flowserve Devices
- Logix 1400 Valve Controller
- NVUF20P3NR Buswitch
* Support for the following Fuji Electric Devices
- FCX-A2 Pressure Transmitter
* Support for the following Honeywell Devices
- ST3000FF Pressure Transmitter
- ST35F Temperature Transmitter
* Support for the following Invensis Devices
- SRD991 Invensis Intelligent Positioners
- SRD960 Invensis Intelligent Positioners
* Support for the following KROHNE Messtechnik GmbH Devices
- BM 70A/P Radar Level Meter
- BM 100 Reflex Radar Level Meter
- IFC090 Magnetic Flow Meter
* Support for the following Ledeen Devices
- LFFC-LD-1.0 Dresser Ledeen Actuator
- Support for the following Metso Automation Devices
- ND 800 Positioner
* Support for the following MicroMotion Devices
- MVD2700 Coriolis Mass Flow Meter
- 5300 Coriolis Flow Meter
* Support for the following Pepperl+Fuchs Devices
- FDO-VC-Ex4 Valve Coupler
* Support for the following Rosemount Analytical Devices
- 1000 BINOS Continuous Gas Analyzer
- 4081 C/T Conductivity Toroid Transmitter
- 4081 pH pH Transmitter
- 4081 F/G Flue Gas Transmitter
- OXT 5000 Oxygen Meter
- 5081A Oxygen Analyzer
* Support for the following Rosemount Devices
- 848T Temperature Transmitter IS Support
- 3051 Pressure Transmitter
- 3244MV Temperature Transmitter
- 8742 Magnetic Flow Meter
- 8800 Vortex Flow Meter
- 5600 Radar Level Transmitter
* Support for the following Samson AG Devices
- Type 3787 Advanced Positioner
* Support for the following SMAR Devices
- FP302 Advanced Positioner Transmitter
- FY302 Basic Positioner Transmitter
- LD302 Pressure Transmitter
- TT302 Temperature Transmitter
- IF302 Current Transmitter
- FI302 Current Output Transmitter
* Support for the following StoneL Corporation Devices
- FF VCT Valve Actuator
* Support for the following Topworx Devices
- DVC-FF Discrete Valve Controller
* Support for the following Westlock Devices
- EL40106 Discrete Valve Controller
* Support for the following Yamatake Corporation Devices
- MagneW3000 Magnetic Flow Meter
* Support for the following Yokogawa Devices
- YTA320 Temperature Transmitter
- YVP Valve Positioner
- EJA100A Pressure Transmitter
- YF100 Vortex Flow Meter
- ADMAG AE 100 Magnetic Flow Meter
- DAQSTATION Chart Recorder
- SC202-F Inductance Conductivity
- PH202-F pH/ORP
- ISC202-F Conductivity/Resistivity
3.
Minor Bug Fixes
* H1 Card now treated as a Device in Spur Length Calculations
* H1 Redundancy Cards now treated as two Devices in Spur Length Calculations
* H1 Card Number now restricted when Redundancy is selected
* Dropping wire on Connected Device no longer causes crash
New In Release 3.5.84
1.
Intrinsic Safety
* IS Power Conditioners
* IS sub-segments highlighting
* IS sub-segment Capacitance checking
* Non-IS Device checking
2.
Cabling
* New Type A and Type B Cables
* Change Cable Type through right-click context menu
* Length Displayed and Changed from Diagram
* Cable Connector Details added to cable properties dialog box
* Set Default Cable Type
* Imperial and Metric Support
* Easy linking to Devices and H1. No need to link to hotspots
* Removed Second Terminal Connection on H1 Card. Due to the internal linkage of the H1 card.
3.
Device Support
* Support for the following El-O-Matic Devices
- 0990 ELQ On/Off Extended
- 7360 ELQ Positioner Extended
* Support for the following Endress+Hausser GmbH Devices
- CERABAR S Pressure Transmitter
- DELTABAR S Pressure Transmitter
- DELTAPILOT S Level Transmitter
- MICROPILOT II Level Transmitter
- MICROPILOT M Level Transmitter
* Support for the following Fisher Controls Devices
- DVC5000f AO/PID Digital Valve Controller
- DVC5000f DO/DI Digital Valve Controller
- DVC5000f Fieldbus Digital Valve Controller
* Support for the following Fisher-Rosemount Systems, Inc. Devices
- H1 Smart Carrier
* Support for the following Flowserve Devices
- Logix 1400 Valve Controller
* Support for the following Krohne Devices
- BM 70 A Radar Level Transmitter
* Support for the following Micro Motion Inc. Devices
- 5300 Coriolis Meter
* Support for the following Rosemount Analytical Devices
- 4081 Flu Gas Transmitter
- 4081C/T Conductivity Transmitter
- 4081pH Transmitter
- 5000 Oxymeter
* Support for the following Rosemount Devices
- 3051 Pressure Transmitter
- 3244MV Temperature Transmitter
- 848T Temperature Transmitter
- 8742C Magnetic Flow Meter
- 8800 Vortex Flow Meter
* Support for the following SMAR Devices
- FI302 Current Output Transmitter
- IF302 Current Transmitter
- LD302 Pressure Transmitter
- TT302 Temperature Transmitter
* Support for the following Yokogawa Devices
- EJA Series Pressure Transmitter
- YEWFLO Series Vortex Flow Meter
4.
Other Supported Items
* DeltaV H1 Card
* DeltaV Redundant H1 Card
* MTL5995 Power Conditioner
* MTL5053 IS Power Conditioner
* SD32R Surge Protector
* Interlink BT 6, 8 and 10 Port Brick
* Interlink BT T Connector
* Interlink BT Terminator
* 5, 10 and 15 point Terminal Blocks
* Terminal Block Terminator
5.
Reporting
* Full Report with Diagrams and Summary Tables
6.
Item Dialogs
* H1 Card Details
* Power Conditioner Details and IS Summary
* Connector Linkage and Termination Details
* Device Details
* Cable Details and Linkage Details
7.
Diagram Details
* Drag and Drop Interface from Item Hierarchy
* Draw Text Boxes with optional Outline
* Draw Lines and Boxes with different Widths
* Display Terminators on Power Conditioners and Connectors
* Highlight Warnings and Errors on Diagram
* Cable Errors is Red
* Item Warning with Yellow Bullet with !
* Item Errors with Red Bullet with X
* Predefined starting Segment Templates for Quick Start
* Segment copy facility
* Auto Device Addressing
* Auto Device Revisions
* Backup LAS Support
8.
General
* Reorganised Tree Layout
* Segment Trees Added
* New Toolbar Options
* Added Pre-built Templates to Start Segment
* Add Windows Explorer support, open existing .seg files by double click
* Fixed several minor bugs
* Online Help
New In Release 3.5.82
1.
Online Help
The Help System has been rebuilt using HTML Help, this can be accessed from the Help -> Online Help menu.
2.
Device Addressing
Devices can now be addressed, the system will automatically assign addresses using the DeltaV addressing scheme.
Auto addressing can also be user defined
3.
Device Description Revision
Devices now have a Device Description Revision, this feature has been added to aid the fhx export that will be
added in a future release.
4.
Backup LAS
Devices that support Backup LAS can be configured to use this option. This forces the address to 20 to comply with
DeltaV. This feature has been added to aid the fhx export that will be added to a future release.
5.
Polyethylene and PVC Cables
The number of cable types has been doubled to include PVC Cables, these have double the capacitance of
equivalent Polyethylene cables.
6.
Registration Process
The Registration Screen has been prevented from covering other applications. This should make it much easier to
use during the online registration process.
7.
Registration Key
You can now view your Registration Key from the Splash screen and About Screen.
8.
Metric / Imperial Measurement
The tool will remember on a Per User basis the default Measurement Units.
9.
Device Connector Options
Support has been added to allow device connector options to be selected.
10.
Segment Tree Layout
Each Segment is built in the TreeView with a Connection Based Hierarchy, rooted with the H1 Card. The Tree will
also display all warning and error message.
Known Errata / Limitations
1.
Termination and sub segments
The Segment Design Tool does not take into account sub-segment classification nor does it take into account
validation and positioning of the terminators on such Segments.
2.
Non-Physical Limitation Checks
The Segment Design Tool does not perform the following checks, and these should be verified manually
- Total Function Block Limit Per H1 Card
- Total VCR Limit Per H1 Card
- Total VCR Limit Per Fieldbus Device
- Communication Overloading
Proposed New Functionality
1.
Export FHX
The ability to export an FHX from the tool ready to be imported in to DeltaV Explorer. Automatically creating
Controllers, Cards, Ports and Devices for each Segment Defined
2.
Creation of Segment Graphics
The ability to generate DeltaV Operate Graphics with the Segments detailed, including links to each Devices
Communication Status, and ability to launch AMS Inside from these
3.
Online Mode
The ability to switch to an online mode where status information would be collected via OPC for each device and
the ability to analyse errors to determine probable issues on the Segment
END OF FILE