In this training module you will learn
about surge protection solutions for:
CCTV / Surveillance Systems
 Access Control Systems
 Fire & Burg Alarm Systems
 Voice & Data Communication Systems
 AC Power


Understand the causes and effects of
power surges

Easily select the proper DITEK surge
protection products for your customer’s
application



Founded in 1985 with headquarters in Largo,
Florida (in the Tampa Bay Area – the Lightning Capital of the U.S!)
Named one of Florida’s Top 50 Fastest Growing
Technology companies
Recipient of Governor’s Leadership award




Founded in 1985 with headquarters in Largo,
Florida (in the Tampa Bay Area – the Lightning Capital of the U.S!)
Named one of Florida’s Top 50 Fastest Growing
Technology companies
Recipient of Governor’s Leadership award
JIT Manufacturer





Founded in 1985 with headquarters in Largo,
Florida (in the Tampa Bay Area – the Lightning Capital of the U.S!)
Named one of Florida’s Top 50 Fastest Growing
Technology companies
Recipient of Governor’s Leadership award
JIT Manufacturer
24/7 Technical Support
Active participants in shaping of
UL,IEEE, IEC,ANSI, and SIA
standards

Surges and Spikes are an
increase in “normal”
electrical line voltage that
can cause serious damage
to equipment.

Surges can be present on
any metallic conductor
including utility power lines,
telephones, computer data
lines, CCTV and CATV cable
feeds.

Lightning Transients

Utility Grid/Capacitor
Switching

Inductive Loads
The effects of surges and spikes are:
of Equipment – gradual
deterioration of internal circuitry
 Degradation
 Destruction – resulting in expensive
equipment replacement costs
 Downtime – lost productivity, loss of life

Reduced Downtime

Reduced Non-Billable Service Calls

Increased Profits

Surge protectors shunt the voltage
surge to ground

A good ground is imperative

NEC code maximum resistance at
ground is 25 Ohms
Whatever equipment your customer
can’t afford to lose.

Surveillance Systems

Access Control Systems

Fire & Burg Alarm Systems

Voice & Data Communication
Systems

AC Power
PTZ Camera Surge Protection
DTK-DP4P
3-in-1 protection –
Coax, power and data
(RS485) feeds
Fixed Camera Surge Protection
DTK-PVP27B
Protects 12V/24V
power and BNC coax
video feed
Video Camera Surge Protection
DTK-VSP-BNC-A
Analog or Digital Video
Available in single or
dual coax feeds
In-line Camera Surge Protection
DTK-iBNC
Designed for camera
locations where no
ground is available for
surge protection
DVR Surge Protection
DTK-DRP16
Complete protection for
4 AC outlets, 16 coax, 1
RJ11, 1 RJ45 feeds and
450VA UPS
2.8 volt clamping
RS485 / 422 Data Line Surge Protection
DTK-LVLP-D
Protects matrix
controllers or DVR from
induced surges on
RS485/422 data lines
Available in 1-8 pair
configurations
Rack Mount Video Surge Protection
DTK-RM16NM
Features 16 in/out
BNC coax
connections with a
single point ground
Rack Mount AC Power Surge Protection
DTK-RMAC9
9 protected outlets
System Status at-aglance via multiple
diagnostics
Available in 15 or 20
amp configurations
RS485 / 422 Data Line Surge Protection
DTK-LVLP-D
Protects matrix
controllers or DVR from
induced surges on
RS485/422 data lines
Available in 1-8 pair
configurations
Card Reader / Keypad Surge Protector
DTK-4LVLP-CR
One unit protects 12 or 24
volt power, data, and LED
wires
Ideal for both pedestal
and wall mount
applications
(For Wiegand Type Readers use
DTK-3LVLP-X)
Door Strike Surge Protector
DTK-ESS
Self-dissipating
No independent
grounding necessary
Control Panel AC Power Surge Protector
DTK-8FF
Heavy duty - 4 standard
outlets, 4 transformer
size outlets, and 1 telco
port
Diagnostic LEDs for
ground presence and
unit function
Door Access Kits
Protection for Panel,
Reader, and Door Strikes
DPK1:
Contains (1) DTK-8F, (2) DTKESS, and (1) DTK-4LVLP-CR
DPK2: for Wiegand-type
readers
Includes: (1) DTK-8F, (2) DTKESS and (1) DTK-3LVLP-X
Telephone Entry Panel Surge Protector
DTK-4LVTEP
Protects 1 Telco line,
1 data line, and 12 / 24
volt power
Series connection
Single point ground
Card Reader / Keypad Surge Protector
DTK-4LVLP-CR
One unit protects 12 or
24 volt power, data, and
LED wires
Ideal for both pedestal
and wall mount
applications
(For Wiegand Type Readers use
DTK-3LVLP-X)
Gate Controller AC Power Surge Protector
DTK-120HW
Hardwire 120 volt surge
protector with a parallel
connection - UL 1449
Diagnostic indicator
confirms ground
presence, unit function,
and power on
Exit & Safety Loop Circuit Surge Protector
DTK-4LVLP-D
Protects ≤ 6V Circuits
including Loop
Detectors & Controller
Data line
Available in 2,4,6,8 pair
configurations
Series connection
Commercial Gate Access Kit
DTK-GPK1
Protects 120V Power,
Telco Entry Panel, Card
Reader/Keypad, Data
Lines & Loop Detectors
Kit includes (1) DTK120HW, (1) DTK-4LVLPCR, (1) DTK-4LVTEP, &
(1) DTK-4LVLP-D
Gate Controller AC Power Surge Protector
DTK-120HW
Hardwire 120 volt surge
protector with a parallel
connection - UL 1449
Diagnostic indicator
confirms ground
presence, unit function,
and power on
Telephone Entry Panel Surge Protector
DTK-4LVXR
Protection for 12 / 24
volt power and two
telephone lines
Series connection
Single point ground
Residential Gate Access Kit
DTK-GPK2
Protects 120V Power
and Telco Entry Panel
Kit includes (1) DTK120HW, (1) DTK-4LXR
Exit & Safety Loop Circuit Surge Protector
DTK-2LVLP-D
Protects ≤ 6V Circuits
including Loop
Detectors & Controller
Data line
Available in 2,4,6,8 pair
configurations
Series connection
Is downtime an option in your
life safety installations?
Alarm Panel AC Power Surge Protector
DTK-120HW
Hardwire 120 volt surge
protector with a parallel
connection - UL 1449
Diagnostic indicator
confirms ground
presence, unit function,
and power on
Alarm Panel AC Power Surge Protector
DTK-120S15A
120 volt critical load
surge protector
allowing for a series
connection
Features include:
multiple diagnostics,
user replaceable fuse,
and RFI/EMI filtering
Alarm Panel Dialer Surge Protector
DTK-MRJ31XSCPWP
Provides over-voltage
and over-amperage
protection for
telephone lines via a
modular connection
in/out
Fire Protection Kit
DTK-FPK
Complete protection for
power and two dialers
Kit contains:
(1) DTK-120HW and
(2) DTK-MRJ31XSCPWP
Notification & Signaling Circuit Surge Protection
DTK-LVLP-LV
Ideal for “Off Premise”
or “At Risk” circuits
Available in 1-8 pair
(2-16 wire) configurations
Screw terminal
connection
Voltage Specific SLC Data Line Protection
DTK-2LVLP-D
(5V Typ.)
DTK-2LVLP-F
(24V Typ.)
DTK-2MLP24B
(24V Typ. Modular)
DTK-2MHLP36B
(36V Typ. Hybrid)
AC Power Surge Protector
DTK-1F
One outlet plug-in with 2 ¼
security screw to secure
transformer & surge protector
to outlet
Diagnostic indicator shows
ground presence and unit
function
Alarm Dialer Surge Protector
DTK-MRJ31XSCP-WP
Over voltage and overamperage protection
Modular Design – ease of
installation
Resettable fusing and patch
cord
Remote Zone Circuit
Surge Protector
DTK-2LVLP-X
Protects 7-14 volt circuits
Two pair configuration
Series connection
Power & Telco Surge Protector
DTK-1F31X
Protects 1 outlet and 1
telephone line
Ideal for use where telco
ground is not easily accessible
Security Screw
Diagnostic indicator
Alarm Dialer Surge Protector
DTK-2LVLPSCP-RUV
Protects incoming phone line
and alarm panel dialer
Two pair configuration
Resettable fusing
Burglar Alarm Surge Protector Kit
DTK-APK1
Used when telco ground is present
at alarm panel
Contains: (1) DTK-1F and (1) DTKMRJ31XSCP-WP
DTK-APK2
Used when telco ground is only
accessible at D-Mark.\
Contains (1) DTK-1F and (1) DTK2LVLPSCP-RUV
Industry
Average Cost of Downtime
Cellular Communications
$41,000 per hour*
Airline Reservations
$90,000 per hour**
Credit Card Operations
$2,580,000 per hour**
Brokerage Operations
$6,480,000 per hour**
•Teleconnect Magazine
**Contingency Planning Research - 1996
KSU AC Power Surge Protector
DTK-3GTP
3 protected outlets
Chassis ground lug
Diagnostic LED
indicates unit function
and ground presence
KSU AC Power Surge Protector
DTK-8FF
Heavy duty
4 standard outlets,
4 transformer size
outlets, and 1 telco
port
Diagnostic LEDs for
ground presence and
unit function
KSU AC Power Surge Protector
DTK-BU450
Protection for 7 AC
outlets, telephone/
modem and optional
CAT5
450VA battery back up
keeps system running
for approx. 15-20
minutes
66 Block Snap-On Surge Protector
DTK-SL & SI SERIES
Modular design allows
multiple voltages on one
block
Over voltage protection
DTK-SL-130A – 130 volt
DTK-SL-50A – 50 volts
DTK-SI-6A – 6 volts
Multi-function diagnostic
LED and self-resetting fuse
Designed for use on
standard 25 pair wiring
SnapLite Ground Bar
DTK-SIGB
Provides single point
ground for up to 25
pairs
Required with use of
DTK-SL devices
Telephone Protection Kit
DTK-TPK-L8
Includes eight
SL-XXX*, one
DTK-SIGB, and one
DTK-3GTP
*specify voltage
Alternate 66 Block Surge Protection
DTK-MT25PSCP
RJ21X to RJ21X 25
pair surge protector
Mass terminating Amphenol
connections
Provides over- voltage
protection (6V, 14V, 30V,
50V, 75V, 95V, 130V), selfresetting fuse
Alternate 66 Block Surge Protection
DTK-P SERIES
Parallel punch down
hard wire surge
protector
Available in 1-25 pairs
Provides over-voltage
protection (6V, 14V,
30V, 50V, 75V, 95V,
130V)
Alternate 66 Block Surge Protection
DTK-MRJ45SCP
Over voltage
protection for T1 lines
Available in 6V, 14V,
30V, 50V, 75V, 95V, and
130V configurations
Easy installation via
plug-and-play RJ45
jack
Alternate 66 Block Surge Protection
DTK-LVLP SERIES
C.O. line surge
protector
Available in 7 voltages
1-8 pair wiring
configurations
available
KSU AC Power Surge Protector
DTK-3GTP
3 protected outlets
Chassis ground lug
Diagnostic LED
indicates unit function
and ground presence
KSU AC Power Surge Protector
DTK-8FF
Heavy duty
4 standard outlets,
4 transformer size
outlets, and 1 telco
port
Diagnostic LEDs for
ground presence and
unit function
KSU AC Power Surge Protector
DTK-BU450
Protection for 7 AC
outlets, telephone/
modem and optional
CAT5
450VA battery back up
keeps system running
for approx. 15-20
minutes
66 Block Snap-On Surge Protector
DTK-SL SERIES
Modular design allows
multiple voltages on one
block
Over voltage protection
DTK-SL-30A – 30 volts
DTK-SL-95A – 95 volts
DTK-SL-50A – 50 volts
Multi-function diagnostic
LED and self-resetting fuse
Designed for use on
standard 25 pair wiring
SnapLite Ground Bar
DTK-SIGB
Provides single point
ground for up to 25
pairs
Required with use of
DTK-SL devices
Network Server Surge Protector
DTK-BU450
Protection for 7 AC
outlets, telephone/
modem and optional
CAT5
450VA battery back up
keeps system running
for approx. 15-20
minutes
Fax Machine Surge Protector
DTK-1FF
Protects single AC
outlet and fax /
modem line
Intercom AC Power Surge Protector
DTK-8FF
Heavy duty
4 standard outlets,
4 transformer size
outlets, and 1 telco
port
Diagnostic LEDs for
ground presence and
unit function
Rack Mount AC Power Surge Protector
DTK-RMAC9
9 protected outlets
System Status at-aglance via multiple
diagnostics
Available in 15 or 20
amp configurations
66 Block Snap-On Surge Protector
DTK-SL & DTK-SLS SERIES
Modular design allows
multiple voltages on one
block
Provides over voltage
protection (30V, 50V, 75V, 95V,
130V) and self-resetting fuse
Multi-function diagnostic
LED
SL Series designed for use
on standard 25 pair wiring
SLS Series is for use on split
block wiring for 50 pairs
SnapLite Ground Bar
DTK-SIGB
Provides single point
ground for 25 to 50
pairs
Required with use of
DTK-SL and DTK-SLS
devices
Alternate 66 Block Surge Protection
DTK-MT25PSCP
RJ21X to RJ21X 25
pair surge protector
Mass terminating Amphenol
connections
Provides over- voltage
protection (6V, 14V, 30V,
50V, 75V, 95V, 130V), selfresetting fuse
DTK-P SERIES
Parallel punch down
hard wire surge
protector
Available in 1-25 pairs
Provides over-voltage
protection (6V, 14V,
30V, 50V, 75V, 95V,
130V)
Power quality issues cost US industries
$26 billion per year!*
*Electric Light & Power Magazine – March 2001
DTGXL Series
Category C Surge Protector
Available in 12 voltage/wiring
configurations (120-1, 120/240-1,
120/208-3Y, 120/240-3HL,220/380-3Y,
277/480-3Y, 347/600-3Y, 208-3D, 240-3D,
380-3D, 480-3D, 600-3D)
RFI/EMI noise filtering
Options include NEMA 4X or
flush enclosure, audible alarm,
dry contacts, and surge counter
UL1449
DTG & DTGX Series
Main & Sub Panel Surge
Protector
Available in 12 voltage/wiring
configurations (120-1, 120/240-1,
120/208-3Y, 120/240-3HL,220/380-3Y,
277/480-3Y, 347/600-3Y, 208-3D, 240-3D,
380-3D, 480-3D, 600-3D)
RFI/EMI noise filtering
Options include NEMA 4X or
flush enclosure, audible alarm,
dry contacts, and surge counter
UL1449
DTK-D75
Commercial Sub Panel Surge
Protector
Available in 4 voltage/wiring
configurations (120T, 120Y, 220Y,
277Y)
Excellent RFI/EMI noise filtering
Options include flush enclosure,
audible alarm, dry contacts, and
surge counter
UL1449
DTK-D50
Commercial Sub Panel Surge
Protector
Available in 4 voltage/wiring
configurations (120T, 120Y, 220Y,
277Y)
Excellent RFI/EMI noise filtering
Options include flush enclosure,
audible alarm, dry contacts, and
surge counter
UL1449
DTK-120/240/480 CM + Series
Secondary Surge Arrester
Economical protection for
pumps, motors, and HVAC
condensers
Available for single phase and
three phase
Weatherproof – Indoor/Outdoor
use
Parallel connection
UL listed
DTK-120/240SA
Class C Residential Service
Entrance Surge Arrester
Designed for meter base or
panel installation
Excellent RFI/EMI noise filtering
Weatherproof enclosure
Unique “ground quality”
diagnostic circuit
DTK-120/240 CM Plus
Secondary Surge Arrester
Economical protection for pumps,
motors, and HVAC condensers
Weatherproof – Indoor/Outdoor
use
Parallel connection
Diagnostic indictor confirms
ground presence, unit function,
and power on
UL listed
DTK-120/240 HD Series
Designed for meter base or
panel installation
Available for surface or flush
mount panels
Super tight clamping
Excellent RFI/EMI noise
attenuation
Weatherproof enclosure
Dual diagnostic lights
UL1449
DTK-2LVLPSCP-RUV
Two pair telephone line
surge protector
Sneak current protection
Protects all connected
telephone and modems
within a home
DTK-VSP-A Series
Video line coax cable surge
protector
Protect two incoming video lines
and all cable / satellite jacks
within the home
DTK-WH2 - Whole House Kit
Contains (1) DTK-120/240 CM Plus, (1) DTK2LVLPSCP-RUV, and (1) DTK-VSP-A
DTK-WH5 - Whole House Kit
Contains (1) DTK-120/240 HD2, (1) DTK2LVLPSCP-RUV, and (1) DTK-VSP-A
DTK-WH8 - Whole House Kit
Contains (1) DTK-120/240 HD3 (audible alarm), (1)
DTK-2LVLPSCP-RUV, (1) DTK-VSP-A2 (protection for 4
coax feeds) and (1) DTK-120/240CM Plus
DTK-1FF
Protects single AC
outlet and one fax /
modem line
DTK-8FF
Heavy duty surge
protector with telco
protection – 4 standard
outlets and 4 transformer
size outlets
Diagnostic LEDs for
ground presence and unit
function
DTK-DSS
Ideal for cable/satellite systems
Features surge protection for 8
AC outlets, one telephone /
modem line, and two video
feeds
RFI/EMI noise filtering
DTK-PCU1
Designed for high-end audio /
video and home theater systems
Capacitive filter bank improves
sound and picture quality
Protects power, video, data, and
phone in one unit
Multiple diagnostics monitor
power, ground, and surge
protection
1.
What is the type of equipment to protect?
2.
What is the maximum continuous operating
voltage (MCOV)?
3.
What is the maximum current?
4.
How many conductors or wires?
5.
How does the application terminate?
1.
ABC RULE – The conductor length between ‘A’ (your equipment) and ‘B’
(DITEK) should be greater than the conductor length between ‘B’ (DITEK) and
‘C’ (Ground Rod)
A---------------------------------------------B----------------C
Equipment
DITEK
Ground Reference
2.
THREE FOOT RULE – The conductor length between ‘A’ and ‘B’ should be 3-6
feet
3.
PARALLEL CONNECTION RULE – Keep conductor to ground as short and
straight as possible
4.
GROUND RESISTANCE RULE – Max ground resistance is 25 ohms. Five
ohms or less preferred
5.
BONDED GROUND RULE – In a system with multiple ground rods, the rods
should be directly connected with no equipment in ground path
6.
PMI – PREVENTATIVE MAINTENANCE INSPECTIONS – Should be monthly
and immediately following local lightning strikes
Suggested Grounding Points
(ranked by optimum performance)
1. Grounded Building Steel
2. Electrical Service Ground
3. Cold Water Pipe (verify no PVC!)
4. Dedicated Driven Rod
5. Local Electrical Ground
TIP: Always verify the quality of the ground – never assume!

Website: www.ditekcorp.com
