Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
This is not the International Symbol for Surge Protection… But it should be! In this training module you will learn about surge protection solutions for: CCTV / Surveillance Systems Access Control Systems Fire & Burg Alarm Systems Voice & Data Communication Systems AC Power Understand the causes and effects of power surges Easily select the proper DITEK surge protection products for your customer’s application Founded in 1985 with headquarters in Largo, Florida (in the Tampa Bay Area – the Lightning Capital of the U.S!) Named one of Florida’s Top 50 Fastest Growing Technology companies Recipient of Governor’s Leadership award Founded in 1985 with headquarters in Largo, Florida (in the Tampa Bay Area – the Lightning Capital of the U.S!) Named one of Florida’s Top 50 Fastest Growing Technology companies Recipient of Governor’s Leadership award JIT Manufacturer Founded in 1985 with headquarters in Largo, Florida (in the Tampa Bay Area – the Lightning Capital of the U.S!) Named one of Florida’s Top 50 Fastest Growing Technology companies Recipient of Governor’s Leadership award JIT Manufacturer 24/7 Technical Support Active participants in shaping of UL,IEEE, IEC,ANSI, and SIA standards Surges and Spikes are an increase in “normal” electrical line voltage that can cause serious damage to equipment. Surges can be present on any metallic conductor including utility power lines, telephones, computer data lines, CCTV and CATV cable feeds. Lightning Transients Utility Grid/Capacitor Switching Inductive Loads The effects of surges and spikes are: of Equipment – gradual deterioration of internal circuitry Degradation Destruction – resulting in expensive equipment replacement costs Downtime – lost productivity, loss of life Reduced Downtime Reduced Non-Billable Service Calls Increased Profits Surge protectors shunt the voltage surge to ground A good ground is imperative NEC code maximum resistance at ground is 25 Ohms Whatever equipment your customer can’t afford to lose. Surveillance Systems Access Control Systems Fire & Burg Alarm Systems Voice & Data Communication Systems AC Power PTZ Camera Surge Protection DTK-DP4P 3-in-1 protection – Coax, power and data (RS485) feeds Fixed Camera Surge Protection DTK-PVP27B Protects 12V/24V power and BNC coax video feed Video Camera Surge Protection DTK-VSP-BNC-A Analog or Digital Video Available in single or dual coax feeds In-line Camera Surge Protection DTK-iBNC Designed for camera locations where no ground is available for surge protection DVR Surge Protection DTK-DRP16 Complete protection for 4 AC outlets, 16 coax, 1 RJ11, 1 RJ45 feeds and 450VA UPS 2.8 volt clamping RS485 / 422 Data Line Surge Protection DTK-LVLP-D Protects matrix controllers or DVR from induced surges on RS485/422 data lines Available in 1-8 pair configurations Rack Mount Video Surge Protection DTK-RM16NM Features 16 in/out BNC coax connections with a single point ground Rack Mount AC Power Surge Protection DTK-RMAC9 9 protected outlets System Status at-aglance via multiple diagnostics Available in 15 or 20 amp configurations RS485 / 422 Data Line Surge Protection DTK-LVLP-D Protects matrix controllers or DVR from induced surges on RS485/422 data lines Available in 1-8 pair configurations Card Reader / Keypad Surge Protector DTK-4LVLP-CR One unit protects 12 or 24 volt power, data, and LED wires Ideal for both pedestal and wall mount applications (For Wiegand Type Readers use DTK-3LVLP-X) Door Strike Surge Protector DTK-ESS Self-dissipating No independent grounding necessary Control Panel AC Power Surge Protector DTK-8FF Heavy duty - 4 standard outlets, 4 transformer size outlets, and 1 telco port Diagnostic LEDs for ground presence and unit function Door Access Kits Protection for Panel, Reader, and Door Strikes DPK1: Contains (1) DTK-8F, (2) DTKESS, and (1) DTK-4LVLP-CR DPK2: for Wiegand-type readers Includes: (1) DTK-8F, (2) DTKESS and (1) DTK-3LVLP-X Telephone Entry Panel Surge Protector DTK-4LVTEP Protects 1 Telco line, 1 data line, and 12 / 24 volt power Series connection Single point ground Card Reader / Keypad Surge Protector DTK-4LVLP-CR One unit protects 12 or 24 volt power, data, and LED wires Ideal for both pedestal and wall mount applications (For Wiegand Type Readers use DTK-3LVLP-X) Gate Controller AC Power Surge Protector DTK-120HW Hardwire 120 volt surge protector with a parallel connection - UL 1449 Diagnostic indicator confirms ground presence, unit function, and power on Exit & Safety Loop Circuit Surge Protector DTK-4LVLP-D Protects ≤ 6V Circuits including Loop Detectors & Controller Data line Available in 2,4,6,8 pair configurations Series connection Commercial Gate Access Kit DTK-GPK1 Protects 120V Power, Telco Entry Panel, Card Reader/Keypad, Data Lines & Loop Detectors Kit includes (1) DTK120HW, (1) DTK-4LVLPCR, (1) DTK-4LVTEP, & (1) DTK-4LVLP-D Gate Controller AC Power Surge Protector DTK-120HW Hardwire 120 volt surge protector with a parallel connection - UL 1449 Diagnostic indicator confirms ground presence, unit function, and power on Telephone Entry Panel Surge Protector DTK-4LVXR Protection for 12 / 24 volt power and two telephone lines Series connection Single point ground Residential Gate Access Kit DTK-GPK2 Protects 120V Power and Telco Entry Panel Kit includes (1) DTK120HW, (1) DTK-4LXR Exit & Safety Loop Circuit Surge Protector DTK-2LVLP-D Protects ≤ 6V Circuits including Loop Detectors & Controller Data line Available in 2,4,6,8 pair configurations Series connection Is downtime an option in your life safety installations? Alarm Panel AC Power Surge Protector DTK-120HW Hardwire 120 volt surge protector with a parallel connection - UL 1449 Diagnostic indicator confirms ground presence, unit function, and power on Alarm Panel AC Power Surge Protector DTK-120S15A 120 volt critical load surge protector allowing for a series connection Features include: multiple diagnostics, user replaceable fuse, and RFI/EMI filtering Alarm Panel Dialer Surge Protector DTK-MRJ31XSCPWP Provides over-voltage and over-amperage protection for telephone lines via a modular connection in/out Fire Protection Kit DTK-FPK Complete protection for power and two dialers Kit contains: (1) DTK-120HW and (2) DTK-MRJ31XSCPWP Notification & Signaling Circuit Surge Protection DTK-LVLP-LV Ideal for “Off Premise” or “At Risk” circuits Available in 1-8 pair (2-16 wire) configurations Screw terminal connection Voltage Specific SLC Data Line Protection DTK-2LVLP-D (5V Typ.) DTK-2LVLP-F (24V Typ.) DTK-2MLP24B (24V Typ. Modular) DTK-2MHLP36B (36V Typ. Hybrid) AC Power Surge Protector DTK-1F One outlet plug-in with 2 ¼ security screw to secure transformer & surge protector to outlet Diagnostic indicator shows ground presence and unit function Alarm Dialer Surge Protector DTK-MRJ31XSCP-WP Over voltage and overamperage protection Modular Design – ease of installation Resettable fusing and patch cord Remote Zone Circuit Surge Protector DTK-2LVLP-X Protects 7-14 volt circuits Two pair configuration Series connection Power & Telco Surge Protector DTK-1F31X Protects 1 outlet and 1 telephone line Ideal for use where telco ground is not easily accessible Security Screw Diagnostic indicator Alarm Dialer Surge Protector DTK-2LVLPSCP-RUV Protects incoming phone line and alarm panel dialer Two pair configuration Resettable fusing Burglar Alarm Surge Protector Kit DTK-APK1 Used when telco ground is present at alarm panel Contains: (1) DTK-1F and (1) DTKMRJ31XSCP-WP DTK-APK2 Used when telco ground is only accessible at D-Mark.\ Contains (1) DTK-1F and (1) DTK2LVLPSCP-RUV Industry Average Cost of Downtime Cellular Communications $41,000 per hour* Airline Reservations $90,000 per hour** Credit Card Operations $2,580,000 per hour** Brokerage Operations $6,480,000 per hour** •Teleconnect Magazine **Contingency Planning Research - 1996 KSU AC Power Surge Protector DTK-3GTP 3 protected outlets Chassis ground lug Diagnostic LED indicates unit function and ground presence KSU AC Power Surge Protector DTK-8FF Heavy duty 4 standard outlets, 4 transformer size outlets, and 1 telco port Diagnostic LEDs for ground presence and unit function KSU AC Power Surge Protector DTK-BU450 Protection for 7 AC outlets, telephone/ modem and optional CAT5 450VA battery back up keeps system running for approx. 15-20 minutes 66 Block Snap-On Surge Protector DTK-SL & SI SERIES Modular design allows multiple voltages on one block Over voltage protection DTK-SL-130A – 130 volt DTK-SL-50A – 50 volts DTK-SI-6A – 6 volts Multi-function diagnostic LED and self-resetting fuse Designed for use on standard 25 pair wiring SnapLite Ground Bar DTK-SIGB Provides single point ground for up to 25 pairs Required with use of DTK-SL devices Telephone Protection Kit DTK-TPK-L8 Includes eight SL-XXX*, one DTK-SIGB, and one DTK-3GTP *specify voltage Alternate 66 Block Surge Protection DTK-MT25PSCP RJ21X to RJ21X 25 pair surge protector Mass terminating Amphenol connections Provides over- voltage protection (6V, 14V, 30V, 50V, 75V, 95V, 130V), selfresetting fuse Alternate 66 Block Surge Protection DTK-P SERIES Parallel punch down hard wire surge protector Available in 1-25 pairs Provides over-voltage protection (6V, 14V, 30V, 50V, 75V, 95V, 130V) Alternate 66 Block Surge Protection DTK-MRJ45SCP Over voltage protection for T1 lines Available in 6V, 14V, 30V, 50V, 75V, 95V, and 130V configurations Easy installation via plug-and-play RJ45 jack Alternate 66 Block Surge Protection DTK-LVLP SERIES C.O. line surge protector Available in 7 voltages 1-8 pair wiring configurations available KSU AC Power Surge Protector DTK-3GTP 3 protected outlets Chassis ground lug Diagnostic LED indicates unit function and ground presence KSU AC Power Surge Protector DTK-8FF Heavy duty 4 standard outlets, 4 transformer size outlets, and 1 telco port Diagnostic LEDs for ground presence and unit function KSU AC Power Surge Protector DTK-BU450 Protection for 7 AC outlets, telephone/ modem and optional CAT5 450VA battery back up keeps system running for approx. 15-20 minutes 66 Block Snap-On Surge Protector DTK-SL SERIES Modular design allows multiple voltages on one block Over voltage protection DTK-SL-30A – 30 volts DTK-SL-95A – 95 volts DTK-SL-50A – 50 volts Multi-function diagnostic LED and self-resetting fuse Designed for use on standard 25 pair wiring SnapLite Ground Bar DTK-SIGB Provides single point ground for up to 25 pairs Required with use of DTK-SL devices Network Server Surge Protector DTK-BU450 Protection for 7 AC outlets, telephone/ modem and optional CAT5 450VA battery back up keeps system running for approx. 15-20 minutes Fax Machine Surge Protector DTK-1FF Protects single AC outlet and fax / modem line Intercom AC Power Surge Protector DTK-8FF Heavy duty 4 standard outlets, 4 transformer size outlets, and 1 telco port Diagnostic LEDs for ground presence and unit function Rack Mount AC Power Surge Protector DTK-RMAC9 9 protected outlets System Status at-aglance via multiple diagnostics Available in 15 or 20 amp configurations 66 Block Snap-On Surge Protector DTK-SL & DTK-SLS SERIES Modular design allows multiple voltages on one block Provides over voltage protection (30V, 50V, 75V, 95V, 130V) and self-resetting fuse Multi-function diagnostic LED SL Series designed for use on standard 25 pair wiring SLS Series is for use on split block wiring for 50 pairs SnapLite Ground Bar DTK-SIGB Provides single point ground for 25 to 50 pairs Required with use of DTK-SL and DTK-SLS devices Alternate 66 Block Surge Protection DTK-MT25PSCP RJ21X to RJ21X 25 pair surge protector Mass terminating Amphenol connections Provides over- voltage protection (6V, 14V, 30V, 50V, 75V, 95V, 130V), selfresetting fuse DTK-P SERIES Parallel punch down hard wire surge protector Available in 1-25 pairs Provides over-voltage protection (6V, 14V, 30V, 50V, 75V, 95V, 130V) Power quality issues cost US industries $26 billion per year!* *Electric Light & Power Magazine – March 2001 DTGXL Series Category C Surge Protector Available in 12 voltage/wiring configurations (120-1, 120/240-1, 120/208-3Y, 120/240-3HL,220/380-3Y, 277/480-3Y, 347/600-3Y, 208-3D, 240-3D, 380-3D, 480-3D, 600-3D) RFI/EMI noise filtering Options include NEMA 4X or flush enclosure, audible alarm, dry contacts, and surge counter UL1449 DTG & DTGX Series Main & Sub Panel Surge Protector Available in 12 voltage/wiring configurations (120-1, 120/240-1, 120/208-3Y, 120/240-3HL,220/380-3Y, 277/480-3Y, 347/600-3Y, 208-3D, 240-3D, 380-3D, 480-3D, 600-3D) RFI/EMI noise filtering Options include NEMA 4X or flush enclosure, audible alarm, dry contacts, and surge counter UL1449 DTK-D75 Commercial Sub Panel Surge Protector Available in 4 voltage/wiring configurations (120T, 120Y, 220Y, 277Y) Excellent RFI/EMI noise filtering Options include flush enclosure, audible alarm, dry contacts, and surge counter UL1449 DTK-D50 Commercial Sub Panel Surge Protector Available in 4 voltage/wiring configurations (120T, 120Y, 220Y, 277Y) Excellent RFI/EMI noise filtering Options include flush enclosure, audible alarm, dry contacts, and surge counter UL1449 DTK-120/240/480 CM + Series Secondary Surge Arrester Economical protection for pumps, motors, and HVAC condensers Available for single phase and three phase Weatherproof – Indoor/Outdoor use Parallel connection UL listed DTK-120/240SA Class C Residential Service Entrance Surge Arrester Designed for meter base or panel installation Excellent RFI/EMI noise filtering Weatherproof enclosure Unique “ground quality” diagnostic circuit DTK-120/240 CM Plus Secondary Surge Arrester Economical protection for pumps, motors, and HVAC condensers Weatherproof – Indoor/Outdoor use Parallel connection Diagnostic indictor confirms ground presence, unit function, and power on UL listed DTK-120/240 HD Series Designed for meter base or panel installation Available for surface or flush mount panels Super tight clamping Excellent RFI/EMI noise attenuation Weatherproof enclosure Dual diagnostic lights UL1449 DTK-2LVLPSCP-RUV Two pair telephone line surge protector Sneak current protection Protects all connected telephone and modems within a home DTK-VSP-A Series Video line coax cable surge protector Protect two incoming video lines and all cable / satellite jacks within the home DTK-WH2 - Whole House Kit Contains (1) DTK-120/240 CM Plus, (1) DTK2LVLPSCP-RUV, and (1) DTK-VSP-A DTK-WH5 - Whole House Kit Contains (1) DTK-120/240 HD2, (1) DTK2LVLPSCP-RUV, and (1) DTK-VSP-A DTK-WH8 - Whole House Kit Contains (1) DTK-120/240 HD3 (audible alarm), (1) DTK-2LVLPSCP-RUV, (1) DTK-VSP-A2 (protection for 4 coax feeds) and (1) DTK-120/240CM Plus DTK-1FF Protects single AC outlet and one fax / modem line DTK-8FF Heavy duty surge protector with telco protection – 4 standard outlets and 4 transformer size outlets Diagnostic LEDs for ground presence and unit function DTK-DSS Ideal for cable/satellite systems Features surge protection for 8 AC outlets, one telephone / modem line, and two video feeds RFI/EMI noise filtering DTK-PCU1 Designed for high-end audio / video and home theater systems Capacitive filter bank improves sound and picture quality Protects power, video, data, and phone in one unit Multiple diagnostics monitor power, ground, and surge protection 1. What is the type of equipment to protect? 2. What is the maximum continuous operating voltage (MCOV)? 3. What is the maximum current? 4. How many conductors or wires? 5. How does the application terminate? 1. ABC RULE – The conductor length between ‘A’ (your equipment) and ‘B’ (DITEK) should be greater than the conductor length between ‘B’ (DITEK) and ‘C’ (Ground Rod) A---------------------------------------------B----------------C Equipment DITEK Ground Reference 2. THREE FOOT RULE – The conductor length between ‘A’ and ‘B’ should be 3-6 feet 3. PARALLEL CONNECTION RULE – Keep conductor to ground as short and straight as possible 4. GROUND RESISTANCE RULE – Max ground resistance is 25 ohms. Five ohms or less preferred 5. BONDED GROUND RULE – In a system with multiple ground rods, the rods should be directly connected with no equipment in ground path 6. PMI – PREVENTATIVE MAINTENANCE INSPECTIONS – Should be monthly and immediately following local lightning strikes Suggested Grounding Points (ranked by optimum performance) 1. Grounded Building Steel 2. Electrical Service Ground 3. Cold Water Pipe (verify no PVC!) 4. Dedicated Driven Rod 5. Local Electrical Ground TIP: Always verify the quality of the ground – never assume! Website: www.ditekcorp.com 24/7 Tech Support: 1-888-472-6100 DITEK Sales Team: 1-800-753-2345