• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Tap 128- 2: How many bulbs will a capacitor light
Tap 128- 2: How many bulbs will a capacitor light

EE – 3410 Electric Power Electromechanical Energy Conversion
EE – 3410 Electric Power Electromechanical Energy Conversion

the limits of the beam sag under influence of static magnetic and
the limits of the beam sag under influence of static magnetic and

... The magnetic flux lines are crossing twice the air gap of width d, as shown in Fig. 1; μ0 is the permeability of air and lΦ is the middle flux line length in the ferromagnetic material of relative permeability μr . A more thorough magnetic field analysis by FEM approach would be beyond the scope of thi ...
non-conventional energy using foot step by converting mechanical
non-conventional energy using foot step by converting mechanical

TRIPURA UNIVERSITY Syllabus
TRIPURA UNIVERSITY Syllabus

... Meter bridge, Carey Foster’s bridge: Working principle and their applications, concept of end corrections in case of meter bridge. Working principle of Potentiometer and its applications, inadequacy of Wheatstone bridge. Thermoelectricity: Seebeck, Peltier and Thomson’s effect, Peltier and Thomson’s ...
Force on Moving Charges in a Magnetic Field
Force on Moving Charges in a Magnetic Field

1.2kV Class Super Energy Efficient K
1.2kV Class Super Energy Efficient K

... the Canadian Energy Efficiency Regulations (SOR/94-651). Total transformer losses are reduced by 30% from the DOE10 CFR Part 431 and/or CSA C802.2 as referenced in the Canadian Energy Efficiency Regulations (SOR/94-651) levels when measured under a linear load (K1) profile at 35% load. There is no e ...
tesfaq 27KB Aug 20 2001 09:27:16 AM - hot
tesfaq 27KB Aug 20 2001 09:27:16 AM - hot

... extinguished. It is much easier to start a gap firing than it is to put it out once it has fired. In Tesla coils quenching the arc is critical to good coil performance. A cold, non-firing, spark gap is "clean". It contains no plasma or hot ions. On applying voltage to the gap, a tension is establish ...
Circuit Monitor - E-MAX Instruments, Inc.
Circuit Monitor - E-MAX Instruments, Inc.

... except that a 30 uF capacitor has been added in parallel with the relay coil (Figure 2). The original purpose of this capacitor was to provide a delay in the dropout of the relay. The 30 uF value provides a release delay of about 200 ms in the DC-operated relays. The presence of this capacitor, in c ...
Manual LED Pulser Driver
Manual LED Pulser Driver

... As will be seen from the sample ‘scope traces the rise and fall time of the units is approx 180nS and some over shoot is present prior to the output pulse settling the overshoot is dependent on the type of diode used and on the current through the diode. The MON output should be used to observe the ...
Pulse Capacitors
Pulse Capacitors

Ideal Transformers
Ideal Transformers

Here - Hot-Spark Performance Products
Here - Hot-Spark Performance Products

Specifying a Solenoid
Specifying a Solenoid

Tests to determine short characteristics of GlueX Solenoid coils one
Tests to determine short characteristics of GlueX Solenoid coils one

... The vulnerability of vapor cooled current leads (VCL) for SC magnets is well documented. The long discharge time of 3960 seconds is a challenge even at 1800 Amps but is solvable. The cost of no burnout current leads with this long discharge time will be some loss of cryogenic efficiency, large size ...
Lecture 3 mathematical example , halfwave rectifier
Lecture 3 mathematical example , halfwave rectifier

Chip tantalum capacitors with built–in open–function
Chip tantalum capacitors with built–in open–function

I B.Tech ISemester (MR15 Regulations)
I B.Tech ISemester (MR15 Regulations)

... 14.A terminal where three or more branches meet is known as__________ 15.A closed path made by several branches of the network is known as__________ 16.An ideal voltage source has __________Internal Resistance 17.Kirchhoff’s law is applicable to__________ 18.example of bilateral element__________ 19 ...
Beakman`s Motor - Rensselaer Polytechnic Institute
Beakman`s Motor - Rensselaer Polytechnic Institute

MOBILE BUG
MOBILE BUG

... Mobile phone uses RF with a wavelength of 30cm at 872 to 2170 MHz. That is the signal is high frequency with huge energy. When the mobile phone is active, it transmits the signal in the form of sine wave which passes through the space. The encoded audio/video signal contains electromagnetic radiatio ...
waves - Island Physics
waves - Island Physics

... • understand and use distance–time graphs • recall and use the relationship between average speed, distance moved and time recall and use the relationship between acceleration, velocity and time • interpret velocity–time graphs • determine acceleration from the gradient of a velocity–time graph and ...
- Eagle Harbor Technologies, Inc.
- Eagle Harbor Technologies, Inc.

... • Reduced switching losses • Lower capacitance due to high current density and small die size. • Operation at 2-5 times the switching frequencies than IGBTs. • Lowest gate drive energy (QG <100 nC) across the recommended input voltage range. • Lower operating temperatures due to higher component eff ...
- Universiti Teknikal Malaysia Melaka Repository
- Universiti Teknikal Malaysia Melaka Repository

CoppeR SHeATHeD CAbLe — SHeATH CuRReNTS
CoppeR SHeATHeD CAbLe — SHeATH CuRReNTS

... single conductor cable. The 60 Hz alternating current flowing in the conductor itself (termed primary current) generates a changing magnetic field which surrounds the entire cable assembly. That field then acts to induce a voltage in the metal sheath of the cable. If the metal sheath is grounded at ...
Bipolar Tesla Coils
Bipolar Tesla Coils

< 1 ... 95 96 97 98 99 100 101 102 103 ... 209 >

Coilgun



A coilgun (or Gauss rifle, in reference to Carl Friedrich Gauss, who formulated mathematical descriptions of the magnetic effect used by magnetic accelerators) is a type of projectile accelerator consisting of one or more coils used as electromagnets in the configuration of a linear motor that accelerate a ferromagnetic or conducting projectile to high velocity. In almost all coilgun configurations, the coils and the gun barrel are arranged on a common axis.Coilguns generally consist of one or more coils arranged along a barrel, so the path of the accelerating projectile lies along the central axis of the coils. The coils are switched on and off in a precisely timed sequence, causing the projectile to be accelerated quickly along the barrel via magnetic forces. Coilguns are distinct from railguns, as the direction of acceleration in a railgun is at right angles to the central axis of the current loop formed by the conducting rails. In addition, railguns usually require the use of sliding contacts to pass a large current through the projectile or sabot but coilguns do not necessarily require sliding contacts. Whilst some simple coilgun concepts can use ferromagnetic projectiles or even permanent magnet projectiles, most designs for high velocities actually incorporate a coupled coil as part of the projectile.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report