• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AYK 550 Air-Modulator
AYK 550 Air-Modulator

... Johnson Controls and other HVAC suppliers have, traditionally, offered Variable Inlet Vanes (VIV) on air handling units to provide this variable air volume capability. VIVs unload the fan by adding a pre-swirl to the air as it enters the fan in such a way as to provide a reduction in head pressure a ...
Hydraulic and Industrial Clutch Catalog
Hydraulic and Industrial Clutch Catalog

... 6-2/3 HP, or the same pump operating at 1500 PSI would need 10 HP, etc. Another rule-of-thumb states that about 5% of the pump maximum rated horsepower is required to idle that pump when it is “unloaded” and the oil is circulating at zero PSI. This amount of power is consumed in flow losses plus me ...
DC Shunt Motors - PSSurvival.com
DC Shunt Motors - PSSurvival.com

... When the shunt motor reaches full rpm, its speed will remain fairly constant. The reason the speed remains constant is due to the load characteristics of the armature and shunt coil. You should remember that the speed of a series motor could not be controlled since it was totally dependent on the si ...
Sensored Field Oriented Control of 3
Sensored Field Oriented Control of 3

... structure of the rotor is designed for the number of desired poles, and the desired flux gradients. The interaction between the stator and the rotor fluxes produces a torque. Since the stator is firmly mounted to the frame, and the rotor is free to rotate, the rotor will rotate, producing a useful m ...
s What is your drive? Lead instead of follow?
s What is your drive? Lead instead of follow?

... High degree of flexibility for successful machine concepts As a member of the new SINAMICS drive family, the SINAMICS S120® drive is part of the modular drive system for high-performance applications in machinery and plant construction. SINAMICS S120 offers high-performance single and multi-axis dri ...
Brushless DC Motor Unit - User`s Guide
Brushless DC Motor Unit - User`s Guide

... for any purpose other than its intended use. Use a direct current power supply with reinforced insulation between the primary and secondary circuits. The manufacturer shall not be held liable for the compensation of any damage caused as a result of neglecting this warning. The performance, specifica ...
weather proof intelli+® actuators
weather proof intelli+® actuators

... Thanks to ABSOLUTE SENSORS, which constantly measure the position & torque of your valve, get precise and reliable information. • Proven measurement principles Torque is measured by a dynamometric balance (calibrated springs) offering a high level of precision, an excellent repeatability as well a ...
view EM-I Question Bank
view EM-I Question Bank

... developed by a D.C. motor?[L2] 10M 4.a)Distinguish between generator and motor action.Derive the equation for the back e.m.f of D.C motor?[L4] 5M b).A 220V shunt motor takes 60A when running at 800 r.p.m It has an armature resistance of 0.1ohms .Find the speed and armature current if the magnetic fl ...
AN3234: Washing Machine Three-Phase AC Induction Motor Drive
AN3234: Washing Machine Three-Phase AC Induction Motor Drive

... Good candidates for this job are vector control techniques. The presented algorithm is based on the implementation of the indirect vector control technique. The control structure overview is illustrated in Figure 3. Similarly, as with other vector control oriented techniques, the implemented algorit ...
practical motor basics
practical motor basics

... is running, the start winding can be cut out of the circuit, and the motor will continue to run on a rotating field that now exists due to the motion of the rotor interacting with the single-phase stator magnetic field. In recent years, the development of power semiconductors and microprocessors has ...
EE2403-QB
EE2403-QB

... 31. What is the step angle of a 5 phases SRM and commutation frequency in each phase for the speed of 6000 rpm. SRM is having 10 stator poles and 4 rotor poles. 32. A SRM with 6 stator poles and 4 rotor poles has a stator pole arc of 30 degree and rotor pole arc of 32 degree. The aligned inductance ...
QUESTION BANK SPECIAL ELECTRICAL MACHINES
QUESTION BANK SPECIAL ELECTRICAL MACHINES

... 31. What is the step angle of a 5 phases SRM and commutation frequency in each phase for the speed of 6000 rpm. SRM is having 10 stator poles and 4 rotor poles. 32. A SRM with 6 stator poles and 4 rotor poles has a stator pole arc of 30 degree and rotor pole arc of 32 degree. The aligned inductance ...
THE FUNDAMENTALS OF AC ELECTRIC INDUCTION MOTOR
THE FUNDAMENTALS OF AC ELECTRIC INDUCTION MOTOR

... slotted ferromagnetic material, but the rotor winding may be either the squirrel-cage type or the wound-rotor type. The latter is of a form similar to that of the stator winding. The winding terminals are brought out to three slip rings. This allows an eternal threephase resistor to be connected to ...
best practice manual-electric motors
best practice manual-electric motors

... Slip represents the inability of the rotor to fully keep up with the moving AC voltage waves generated on the stator. Slip of an induction motor defined as: ...
gTB 2 track guide trouble-shooting guide error/LED codes
gTB 2 track guide trouble-shooting guide error/LED codes

... • Excessive current to motor—Use a milder motor or a smaller pinion gear. • Untidy wires or signal and power wired bundled together. Input harness and servo wires should be bundled separately. Power wires should be as short as possible. ...
Lesson-42
Lesson-42

... attached to each end of the coil as shown in Fig. 42.1(a). These hairsprings are not only supplying a restoring torque but also provide an electric connection to the rotating coil. With the use of hairsprings, the coil will return to its initial position when no current is flowing though the coil. T ...
DESIGN AND SIMULATION BY USING SMART POWER MODULE
DESIGN AND SIMULATION BY USING SMART POWER MODULE

... Universal motors's armatures typically have far more coils and plates than a DC motor, and hence less windings per coil. This reduces the inductance. Motor damage may occur from over-speeding (running at a rotational speed in excess of design limits) if the unit is operated with no significant mech ...
LEESON Basic Training
LEESON Basic Training

... Another commonly used motor in industrial applications is the direct current motor. It is often used in applications where adjustable speed control is required. Permanent magnet DC designs are generally used for motors that produce less than 5 HP. Larger horsepower applications use shunt-wound direc ...
DC Motors and Generators Unit 2
DC Motors and Generators Unit 2

... In the first part of the exercise, you will set up the equipment in the Workstation, connect the equipment as shown in Figure 2-14, and make the appropriate settings on the equipment. In the second part of the exercise, you will measure the armature resistance ܴ஺ of the DC Motor/Generator. It is not ...
KL3518001806
KL3518001806

... quality. The carried out experiments shows that an asymmetrical configuration provides nearly sinusoidal voltages with very low distortion, using less switching devices. In addition, torque ripples are greatly reduced: asymmetrical multilevel inverter enables a DTC solution for high-power induction ...
Chapter 2 Review Solutions SPH4C
Chapter 2 Review Solutions SPH4C

... Students should write equations under appropriate headings, such as torques on levers, mechanical advantage, and percent efficiency. The heading torques on levers should include the equations involved and the three classes of levers. The heading mechanical advantage can also include the different eq ...
DIGIPLAN 1054 STEPPER MOTOR DRIVE INSTRUCTION
DIGIPLAN 1054 STEPPER MOTOR DRIVE INSTRUCTION

... Resistor values for regulated boost Resistor values for peak boost Power supply voltages Resistor values for 208 translator ...
dc motor control card - Country Living Grain Mills
dc motor control card - Country Living Grain Mills

... Under no circumstances should power and logic leads be bundled together. Induced voltage can cause unpredictable behavior in any electronic device, including motor controls. ...
ISL8200MEVAL2PHZ User Guide
ISL8200MEVAL2PHZ User Guide

... The analysis of the circuit in Figure 4 will begin with a discussion of the operation of the HIP2100. HIP2100, U6, is a non-inverting half bridge MOSFET driver capable of driving up to 2A of gate drive into MOSFETs Q17 and Q19. Figure 6 depicts the simplified functional block diagram for the HIP2100 ...
When to use a Soft Starter or an AC Variable... White Paper
When to use a Soft Starter or an AC Variable... White Paper

... an external bypass is used for emergency run (not using the soft start for control), an AC-3 utilization rating is needed. ...
< 1 ... 3 4 5 6 7 8 9 10 11 ... 44 >

Dynamometer



A dynamometer or ""dyno"" for short, is a device for measuring force, torque, or power. For example, the power produced by an engine, motor or other rotating prime mover can be calculated by simultaneously measuring torque and rotational speed (RPM).A dynamometer can also be used to determine the torque and power required to operate a driven machine such as a pump. In that case, a motoring or driving dynamometer is used. A dynamometer that is designed to be driven is called an absorption or passive dynamometer. A dynamometer that can either drive or absorb is called a universal or active dynamometer.In addition to being used to determine the torque or power characteristics of a machine under test (MUT), dynamometers are employed in a number of other roles. In standard emissions testing cycles such as those defined by the United States Environmental Protection Agency (US EPA), dynamometers are used to provide simulated road loading of either the engine (using an engine dynamometer) or full powertrain (using a chassis dynamometer). In fact, beyond simple power and torque measurements, dynamometers can be used as part of a testbed for a variety of engine development activities, such as the calibration of engine management controllers, detailed investigations into combustion behavior, and tribology.In the medical terminology, hand-held dynamometers are used for routine screening of grip and hand strength, and the initial and ongoing evaluation of patients with hand trauma or dysfunction. They are also used to measure grip strength in patients where compromise of the cervical nerve roots or peripheral nerves is suspected.In the rehabilitation, kinesiology, and ergonomics realms, force dynamometers are used for measuring the back, grip, arm, and/or leg strength of athletes, patients, and workers to evaluate physical status, performance, and task demands. Typically the force applied to a lever or through a cable is measured and then converted to a moment of force by multiplying by the perpendicular distance from the force to the axis of the level.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report