How to Construct a Cable for the Garmin eTrex or eMap
... Thank you for obtaining a GPS connector for the Garmin eTrex or eMap receiver from us. This document will provide you with the information you need to construct virtually any type of cable you may require, whether you want to connect your GPS to a computer, or to provide power to your GPS. Technical ...
... Thank you for obtaining a GPS connector for the Garmin eTrex or eMap receiver from us. This document will provide you with the information you need to construct virtually any type of cable you may require, whether you want to connect your GPS to a computer, or to provide power to your GPS. Technical ...
HMC224MS8 / 224MS8E
... SPDT switches in 8-lead MSOP packages for use in transmit-receive applications. The device can control signals from 5.0 to 6.0 GHz and is especially suited for 5.2 GHz UNII and 5.8 GHz ISM applications with only 1.2 dB loss. The design provides exceptional power handling performance; input P1dB = +3 ...
... SPDT switches in 8-lead MSOP packages for use in transmit-receive applications. The device can control signals from 5.0 to 6.0 GHz and is especially suited for 5.2 GHz UNII and 5.8 GHz ISM applications with only 1.2 dB loss. The design provides exceptional power handling performance; input P1dB = +3 ...
methods to enhance optical performance of lenticular lens
... NiMH batteries will self-discharge over time much faster than alkaline batteries. NiMH batteries can self-discharge as much as 1% per day while the shelf life of alkaline batteries can be 5-7 years. W4WB and AB4MT have experienced storage times of several months with the OPP-817 in their FT-817s; ho ...
... NiMH batteries will self-discharge over time much faster than alkaline batteries. NiMH batteries can self-discharge as much as 1% per day while the shelf life of alkaline batteries can be 5-7 years. W4WB and AB4MT have experienced storage times of several months with the OPP-817 in their FT-817s; ho ...
this is a partial SAMPLE of the full manual PAS3-Z modification Overview
... that are generated by solid-state diodes themselves. We continue to use the original power transformer in this modification not only to save an expensive replacement but also because our original SP6 preamp design was optimized to use this transformer in it's design, thus no changes are needed for v ...
... that are generated by solid-state diodes themselves. We continue to use the original power transformer in this modification not only to save an expensive replacement but also because our original SP6 preamp design was optimized to use this transformer in it's design, thus no changes are needed for v ...
Chapter 5 Digital Input Circuit
... 5.2 Structure and Wiring of FBN DC5V High Speed Differential Input Circuit X0~X3 of FBN-19MCT, X0~X7 of FBN-26MCT and X0~X15 of FBN-36MCT are all DC5V high-speed differential inputs (the others are DC24V inputs). The working frequency of these high speed inputs can go up to 512KHz, which is mainly ...
... 5.2 Structure and Wiring of FBN DC5V High Speed Differential Input Circuit X0~X3 of FBN-19MCT, X0~X7 of FBN-26MCT and X0~X15 of FBN-36MCT are all DC5V high-speed differential inputs (the others are DC24V inputs). The working frequency of these high speed inputs can go up to 512KHz, which is mainly ...
Mains Power And Home Audio
... from outside the home that we need to protect our equipment from. Do we need some sort of power conditioner or filter to protect the equipment and remove interference from the incoming mains? Because the designers of our power supply system do not want troublesome ‘noise’ on the mains supply – they ...
... from outside the home that we need to protect our equipment from. Do we need some sort of power conditioner or filter to protect the equipment and remove interference from the incoming mains? Because the designers of our power supply system do not want troublesome ‘noise’ on the mains supply – they ...
VSV300 VibroSmart® DMS vibration monitoring module
... equipment. VibroSmart DMS modules can be mounted directly on machinery, eliminating the need for costly cabling, because it is designed and certified to work in extremes, such as harsh industrial environments characterized by potentially explosive atmospheres (Ex Zone 2), high temperatures (70 °C) a ...
... equipment. VibroSmart DMS modules can be mounted directly on machinery, eliminating the need for costly cabling, because it is designed and certified to work in extremes, such as harsh industrial environments characterized by potentially explosive atmospheres (Ex Zone 2), high temperatures (70 °C) a ...
Mounting the STK503
... Placing the AVR in the ZIF socket The ZIF socket on STK503 takes AVRs in 100-pin TQFP packages. To use STK500 and 100-pin AVR devices with LCD controller such as the ATmega3290 and ATmega6490, you must use the STK504 top module, not STK503. 1. Make sure the STK500 power is switched off. 2. Make sure ...
... Placing the AVR in the ZIF socket The ZIF socket on STK503 takes AVRs in 100-pin TQFP packages. To use STK500 and 100-pin AVR devices with LCD controller such as the ATmega3290 and ATmega6490, you must use the STK504 top module, not STK503. 1. Make sure the STK500 power is switched off. 2. Make sure ...
HMC284MS8G(E)
... 1. Set A/B control to 0/+5V, Vdd = +5V and use HCT series logic to provide a TTL driver interface. 2. Control inputs A/B can be driven directly with CMOS logic (HC) with Vdd = +5 Volts applied to the CMOS logic gates. 3. DC blocking capacitors are required for each RF port as shown. Capacitor value ...
... 1. Set A/B control to 0/+5V, Vdd = +5V and use HCT series logic to provide a TTL driver interface. 2. Control inputs A/B can be driven directly with CMOS logic (HC) with Vdd = +5 Volts applied to the CMOS logic gates. 3. DC blocking capacitors are required for each RF port as shown. Capacitor value ...
True RMS Digital Multimeter Model MN62
... manual before operating the meter. Always remove the test leads before replacing the battery or fuses. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Use great care when making measurements if the voltages are greater than 30VAC rms ...
... manual before operating the meter. Always remove the test leads before replacing the battery or fuses. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Use great care when making measurements if the voltages are greater than 30VAC rms ...
Industry photo: should be a the same image as larger
... style or portrait of engineer. This image and the one above can be of the same individual(s) with different angle or crop. This image will partially be obscured by orange overlay. ...
... style or portrait of engineer. This image and the one above can be of the same individual(s) with different angle or crop. This image will partially be obscured by orange overlay. ...
doc - Ignitech
... Continuous setting start limiter revolution is posible to do by connecting ponciometer in input POT (13). Potenciometer is supplied by reference voltage + 5 V (3) a GND (4, 16, 17). Start limiter revolution is determined by voltage value from 0 to 5 V at input POT and by two values of start limiter ...
... Continuous setting start limiter revolution is posible to do by connecting ponciometer in input POT (13). Potenciometer is supplied by reference voltage + 5 V (3) a GND (4, 16, 17). Start limiter revolution is determined by voltage value from 0 to 5 V at input POT and by two values of start limiter ...
TWR-K21D50M Tower Module Freescale Semiconductor, Inc. 1 TWR-K21D50M Contents
... Three FlexTimers with a total of 12 channels Hardware dead-time insertion and quadrature decoding for motor control Carrier modulator timer for infrared waveform generation in remote control applications Four-channel 32-bit periodic interrupt timer provides time base for RTOS task scheduler, or trig ...
... Three FlexTimers with a total of 12 channels Hardware dead-time insertion and quadrature decoding for motor control Carrier modulator timer for infrared waveform generation in remote control applications Four-channel 32-bit periodic interrupt timer provides time base for RTOS task scheduler, or trig ...
Phone connector (audio)
In electronics, a phone connector, also known as phone jack, audio jack or jack plug, is a common family of connector typically used for analog signals, primarily audio. It is cylindrical in shape, typically with two, three or four contacts. Three-contact versions are known as TRS connectors, where T stands for ""tip"", R stands for ""ring"" and S stands for ""sleeve"". Similarly, two- and four-contact versions are called TS and TRRS connectors respectively.The phone connector was invented for use in telephone switchboards in the 19th century and is still widely used. In its original configuration, the outside diameter of the ""sleeve"" conductor is 1⁄4 inch (exactly 6.35 mm). The ""mini"" connector has a diameter of 3.5 mm (approx. 1⁄8 inch) and the ""sub-mini"" connector has a diameter of 2.5 mm (approx. 3⁄32 inch).