- Integrated
... [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...
... [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...
AC (120V) Isolated Output Module, 16 Outputs Installation Instructions
... on each output circuit. The total continuous current the module supports is 8A (2A maximum per channel). If this rating is exceeded, the module overheats and damage may occur. ...
... on each output circuit. The total continuous current the module supports is 8A (2A maximum per channel). If this rating is exceeded, the module overheats and damage may occur. ...
XEB-26-CFZ - Barron Lighting Group
... 3. CAUTION – This is a sealed unit. The integral, high temperature Ni-Cad battery is not replaceable. Replace the entire unit when necessary and recycle or dispose of the nickel-cadmium battery properly. 4. DO NOT USE OUTDOORS. The XEB-26-CFZ is for use with grounded, UL Listed, indoor fixture ...
... 3. CAUTION – This is a sealed unit. The integral, high temperature Ni-Cad battery is not replaceable. Replace the entire unit when necessary and recycle or dispose of the nickel-cadmium battery properly. 4. DO NOT USE OUTDOORS. The XEB-26-CFZ is for use with grounded, UL Listed, indoor fixture ...
COOPER POWER SERIES Sectionalizing switch installation instructions OEM Equipment
... Sectionalizing switches can be used on single- and threephase grounded wye or delta systems. They are used in underground residential applications with loop feed, and in three-phase commercial industrial installations where the ability to use an alternative source of power is necessary. They can als ...
... Sectionalizing switches can be used on single- and threephase grounded wye or delta systems. They are used in underground residential applications with loop feed, and in three-phase commercial industrial installations where the ability to use an alternative source of power is necessary. They can als ...
ULD-360DMX and ULD-360DMX-HP USER`S MANUAL
... and acceptable cable, see the Appendix at the end of this manual. For convenience, DMX in and out connectors are provided on the ULD-360DMX. This allows easy connection to additional dimmer packs. The DMX standard allows up to 32 dimmers to be connected to a single DMX controller. For proper operati ...
... and acceptable cable, see the Appendix at the end of this manual. For convenience, DMX in and out connectors are provided on the ULD-360DMX. This allows easy connection to additional dimmer packs. The DMX standard allows up to 32 dimmers to be connected to a single DMX controller. For proper operati ...
ULD Series Dimmer Manual
... and acceptable cable, see the Appendix at the end of this manual. For convenience, DMX in and out connectors are provided on the ULD-360DMX. This allows easy connection to additional dimmer packs. The DMX standard allows up to 32 dimmers to be connected to a single DMX controller. For proper operati ...
... and acceptable cable, see the Appendix at the end of this manual. For convenience, DMX in and out connectors are provided on the ULD-360DMX. This allows easy connection to additional dimmer packs. The DMX standard allows up to 32 dimmers to be connected to a single DMX controller. For proper operati ...
Audio Amplifiers
... the TPA3123D2 eliminates the need for an external heat sink when playing music. It supports dual channel amplification and each such channel is rated at 8W which helps producing state-of-the-art sound quality. Integrating high-quality SMD and MKP plug-in capacitors ensures Hi-Fi amplification output ...
... the TPA3123D2 eliminates the need for an external heat sink when playing music. It supports dual channel amplification and each such channel is rated at 8W which helps producing state-of-the-art sound quality. Integrating high-quality SMD and MKP plug-in capacitors ensures Hi-Fi amplification output ...
Evaluation Board Procedure Document
... 5.9(b) Connect a wire from the negative (-) terminal of electronic load #2 (or to one terminal of a resistive load #2) to the negative (-) output terminal Vout- (connector J02 pins 1,2,3) of the Evaluation Board. Connect a wire from the positive (+) terminal of electronic load #2 (or the other termi ...
... 5.9(b) Connect a wire from the negative (-) terminal of electronic load #2 (or to one terminal of a resistive load #2) to the negative (-) output terminal Vout- (connector J02 pins 1,2,3) of the Evaluation Board. Connect a wire from the positive (+) terminal of electronic load #2 (or the other termi ...
Chapter 3 - Geeky Solutions
... PCI Express (PCI-E) - I PCIe 2.0 doubles bandwidth from 0.25 GByte/s to 0.5 GByte/s, meaning a x32 connector can transfer data at up to 16 GByte/s for both video cards PCIe 2.0 have two 32 bits channels for each GPU (2x16), while first version only 1x16 and operating at 2 GHz. PCIe 2.0 is bac ...
... PCI Express (PCI-E) - I PCIe 2.0 doubles bandwidth from 0.25 GByte/s to 0.5 GByte/s, meaning a x32 connector can transfer data at up to 16 GByte/s for both video cards PCIe 2.0 have two 32 bits channels for each GPU (2x16), while first version only 1x16 and operating at 2 GHz. PCIe 2.0 is bac ...
MAX2828EVKIT-MAX2829EVKIT.pdf
... To evaluate the devices in receive mode: 1) Set the RXON jumper (JP22) to the On position and the TXON jumper (JP21) to the Off position. 2) Connect the RF signal source to either RXRFL (802.11g, J4) or RXRFH (802.11a, J3). Set the RF frequency to 2437MHz (802.11g) or 5.25GHz (802.11a). Set the sign ...
... To evaluate the devices in receive mode: 1) Set the RXON jumper (JP22) to the On position and the TXON jumper (JP21) to the Off position. 2) Connect the RF signal source to either RXRFL (802.11g, J4) or RXRFH (802.11a, J3). Set the RF frequency to 2437MHz (802.11g) or 5.25GHz (802.11a). Set the sign ...
BusWorks XT Series Ethernet I/O Modules
... IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module. ■ USB Interface USB Connector Type: USB Mini-B type socket, 5-pin. Data rate: 12Mbps. USB v1.1 and 2.0 compatible. Maximum cable length: 5.0 ...
... IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module. ■ USB Interface USB Connector Type: USB Mini-B type socket, 5-pin. Data rate: 12Mbps. USB v1.1 and 2.0 compatible. Maximum cable length: 5.0 ...
SIL 3 Loop powered 24 to 220 Vac/Vdc Switch Repeater Transistor
... General Description: The single and dual channel 24 to 220 Vac/Vdc Loop Powered Switch Repeater D5093S and D5093D modules are units suitable for applications requiring SIL 3 level (according to IEC 61508:2010 Ed.2) in safety related systems for high risk industries. Each channel is able to reflect t ...
... General Description: The single and dual channel 24 to 220 Vac/Vdc Loop Powered Switch Repeater D5093S and D5093D modules are units suitable for applications requiring SIL 3 level (according to IEC 61508:2010 Ed.2) in safety related systems for high risk industries. Each channel is able to reflect t ...
Tender Specification - Close Talk Conference System
... Transceivers acts as transmitter/receiver antennas for the IR-signals and are connected to the central unit using RJ-45 Cat. 6 cables. The central unit supports up to eight direct connected transceivers, supporting the most common installation sizes. For larger installations or with complex cabling, ...
... Transceivers acts as transmitter/receiver antennas for the IR-signals and are connected to the central unit using RJ-45 Cat. 6 cables. The central unit supports up to eight direct connected transceivers, supporting the most common installation sizes. For larger installations or with complex cabling, ...
HMC349MS8G - SeekDataSheet
... The HMC349MS8G is a high isolation nonreflective DC to 4 GHz GaAs MESFET SPDT switch in a low cost 8 lead MSOP8G surface mount package with an exposed ground paddle. The switch is ideal for cellular/PCS/3G basestation applications yielding 50 to 60 dB isolation, low 0.8 dB insertion loss and +52 dBm ...
... The HMC349MS8G is a high isolation nonreflective DC to 4 GHz GaAs MESFET SPDT switch in a low cost 8 lead MSOP8G surface mount package with an exposed ground paddle. The switch is ideal for cellular/PCS/3G basestation applications yielding 50 to 60 dB isolation, low 0.8 dB insertion loss and +52 dBm ...
Phone connector (audio)
In electronics, a phone connector, also known as phone jack, audio jack or jack plug, is a common family of connector typically used for analog signals, primarily audio. It is cylindrical in shape, typically with two, three or four contacts. Three-contact versions are known as TRS connectors, where T stands for ""tip"", R stands for ""ring"" and S stands for ""sleeve"". Similarly, two- and four-contact versions are called TS and TRRS connectors respectively.The phone connector was invented for use in telephone switchboards in the 19th century and is still widely used. In its original configuration, the outside diameter of the ""sleeve"" conductor is 1⁄4 inch (exactly 6.35 mm). The ""mini"" connector has a diameter of 3.5 mm (approx. 1⁄8 inch) and the ""sub-mini"" connector has a diameter of 2.5 mm (approx. 3⁄32 inch).