• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Coaxial Cable Protection
Coaxial Cable Protection

... to a 50 ohm load). A higher peak voltage will be present if the equipment has internal capacitive coupling to the center conductor of the coax line and could cause arcing at the input. If it is inductive, such as the input of a shunt fed repeater duplexer, the lower frequency voltages are immediatel ...
student identification number (sin)
student identification number (sin)

... Fusion splicing is the act of joining two optical fibers end-to-end using heat. The goal is to fuse the two fibers together in such a way that light passing through the fibers is not scattered or reflected back by the splice, and so that the splice and the region surrounding it are almost as strong ...
Coupled Inductors
Coupled Inductors

... used extensively in electrical applications. Their properties allow for increasing or decreasing voltage and current, transferring impedance through a circuit, and they can isolate two circuits from each other electrically. There are a wide variety of applications which exploit properties of transfo ...
Cabling - Pacific Audio Visual Institute
Cabling - Pacific Audio Visual Institute

... When you connect two devices, one is the source and one is the load. The source is the device that puts out a signal. The load is the device you are feeding the signal into. The source has a certain output impedance, and the load has a certain input impedance. It’s important to match the output impe ...
9. electromagnetic induction
9. electromagnetic induction

... 60. Long distance transmission of electrical energy is effected with the help of it. 61. It does not amplify power. Energy losses in transformer and their minimisation: 62. Copper loss : Due to current flow in primary and secondary coils of a transformer Joule heat is generated in both the coils on ...
Problem 2. - ShareStudies.com
Problem 2. - ShareStudies.com

... line length in wavelengths () to produce an input impedance, Zin =0 - j36. Repeat for Zin = j100. Determine the length of an open circuit line for Zin = j100 Problem 7. An antenna has an input impedance equal to 25 + j40  and a frequency at 100MHz. The antenna is connected to a 50 coaxial cabl ...
Capacitive element based sensor
Capacitive element based sensor

... shown in Figure 2.2.7, say, more in secondary coil 1 than in coil 2, then more emf is generated in one coil i.e. coil 1 than the other, and there is a resultant voltage from the coils. If the magnetic core is further displaced, then the value of resultant voltage increases in proportion with the dis ...
Inductors: Resonance and simulations
Inductors: Resonance and simulations

... Digital radio, also know as satellite radio, offers uninterrupted digital quality music, news, and entertainment transmitted to your radio from satellites. In addition to the encoded sound, the signal contains additional information about the broadcast. The song title, artist and genre of music can ...
PowerPoint
PowerPoint

... This shows how the input signal is split, one half attenuated to 20% of its original height, and the other half delayed. The two are then combined to produce the signal that can be seen at the CF Monitor. ...
amprobe at-1000
amprobe at-1000

... > Heavy duty, recommended for tough industrial applications > Traces live wires buried underground or hidden behind walls up to 13 feet deep > Performs tests without having to interrupt power > Locates breakers, neutral and ground lines > Locates and traces wires in walls, floors, conduit, computer ...
CCNA1 3.0-04 Cable Testing
CCNA1 3.0-04 Cable Testing

... have some amount of noise. Even though noise cannot be eliminated, its effects can be minimized if the sources of the noise are understood. There are many possible sources of noise: ...
Worksheet 8.7 - Transformers
Worksheet 8.7 - Transformers

... 1) Currents of 0.25 A and 0.95 A flow through the primary and secondary coils of a transformer respectively if there are 1.0x103 turns in the primary coil how many turns are in the secondary coil? 2) A step-down transformer has coils of 1.20 x 103 and 1.5- x 102 turns. If the transformer is connecte ...
University of California at Berkeley College of Engineering
University of California at Berkeley College of Engineering

Dia 1 - OH3TR
Dia 1 - OH3TR

... • Antenna is the part of an electromagnetic system that either transforms energy from current and voltage into electromagnetic radiation or vice versa. • An antenna has the same properties regardless of whether it is used as a transmitting or a receiving antenna. ...
- Steelpumps
- Steelpumps

... Voltage drop will affect the cable size needed to take power to any pump used. The more current is drawn the greater the effect over distance. Over very long runs, you may find it more economical to install contactors near to the pumps, allowing you to control the pumps with a sensible cable size. I ...
L N F A B O R A T O R I
L N F A B O R A T O R I

... Figure 8 – LNF–purified D2 O test: After LNF–purification procedure, a high loading (D/Pd= 0.97) have been achieved, lasting several days; an anomalous loading effect occurs after decreasing electrolysis current: it can be explained with a higher temperature of wire occurred during the loading. In t ...
Application of artificial intelligence to the problem of
Application of artificial intelligence to the problem of

... Partial Discharge and Dielectric Loss Estimation (Damped AC) ...
BIDN/** DeviceNet Interface
BIDN/** DeviceNet Interface

... Ordering Information When assembling your part number, please include the corresponding tag suffix. Example: BIDN/XX. - OMX High Speed Industrial R/W Tag Series. (Cables and Connectors Sold Separately) ...
Megger® Hand-Held TDR / Cable Length Meter Megger® Hand
Megger® Hand-Held TDR / Cable Length Meter Megger® Hand

... Handheld TTR with 6ft (1.8m) test leads Test leads, X/H winding, 12ft (3.6m) Test leads, X/H winding, 20ft (6m) Battery/line power thermal printer with paper, battery pack, charger, interface cable ...
magnetic resonant co wireless power trans electric vehicle bat
magnetic resonant co wireless power trans electric vehicle bat

110V/0W = ∞A! P = VI
110V/0W = ∞A! P = VI

test equipment - L-com
test equipment - L-com

lab6 - People @ EECS at UC Berkeley
lab6 - People @ EECS at UC Berkeley

... 3. Measure the peak-to-peak voltage Vpp (including any overshoot), on both the high-to-low and low-tohigh transitions on channel 2. Given that the output range of the 74F04 is approximately 0-3V, comment on the Vpp measured at the end of the transmission line. Record your measurements on the checkof ...
Catalogue - Pyrotech Electronics Udaipur
Catalogue - Pyrotech Electronics Udaipur

... a 4-20mA output. It consists of a small battery powered RF transmitter that digitally sends temperatures obtained from a standard PT100 platinum resistive sensor mounted in the mill shell or diaphragm. The RF receiver is then mounted nearby temperature information to a standard 4-20mA. ...
PRESS RELEASE For immediate release Black Rhodium Introduces
PRESS RELEASE For immediate release Black Rhodium Introduces

... Vibration Stabiliser to Reduce Distortion TITAN mains power cables are fitted with the Graham Nalty legacy Range VS-1 Vibration Stabiliser. The Vibration Stabiliser has been specially designed to reduce audible cable distortion in cables by limiting the effects of vibrations travelling through the c ...
< 1 ... 58 59 60 61 62 63 64 65 66 ... 76 >

Loading coil



A loading coil or load coil is an inductor that is inserted into an electronic circuit to increase its inductance. A loading coil is not a transformer to provide coupling to another other circuit. The term originated in the 19th century for inductors used to prevent signal distortion in long-distance telegraph transmission cables. The term is also used for inductors in radio antennas, or between the antenna and its feedline, to make an electrically short antenna resonant at its operating frequency.Loading coils are historically also known as Pupin coils after Mihajlo Pupin, especially when used for the Heaviside condition and the process of inserting them is sometimes called pupinization.The concept of loading coils was discovered by Oliver Heaviside in studying the problem of slow signalling speed of the first transatlantic telegraph cable in the 1860s. He concluded additional inductance was required to prevent amplitude and time delay distortion of the transmitted signal. The mathematical condition for distortion-free transmission is known as the Heaviside condition. Previous telegraph lines were overland or shorter and hence had less delay, and the need for extra inductance was not as great. Submarine communications cables are particularly subject to the problem, but early 20th century installations using balanced pairs were often continuously loaded with iron wire or tape rather than discretely with loading coils, which avoided the sealing problem.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report