• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Weld Package Semi Automatic mobile
Weld Package Semi Automatic mobile

... The LSQ5 ensures the optimum arc energy. It uniquely adjusts to different weld processes. Unlike conventional power sources with inverter technology, the LSQ5 with Direct Control Technology controls its switching transistors without any fixed clock frequency according to the needs of the weld proces ...
IEEE Std 1018-Revised 1997
IEEE Std 1018-Revised 1997

... and galvanized armor. 3. Cables with copper conductors, EPDM insulation, Lead Sheath and galvanized armor. Cables meeting the requirements of the recommended practice should be rated for voltages not exceeding 3 kV or 5 kV (phase to phase). Conductor temperatures for cables with nitrile jacket shoul ...
PowerPoint Template
PowerPoint Template

...  Cover-plate-weld procedure was studied and performed in order to protect the coil temperature from above 130oC.  In-direct cooling method is used for the large coil through cooling tubing.  All technologies that were developed and adopted in the large prototype coil will be validated by large co ...
Trace Heat Brochure.qxd
Trace Heat Brochure.qxd

... insulated pipes only. For information regarding other applications contact Cable Services. Warning As with any electrical equipment or wiring installation operating at line voltages, heating cable and component damage or incorrect installation that allows the penetration of moisture or contamination ...
45MHz to 650MHz, Integrated IF VCOs with Differential Output General Description Features
45MHz to 650MHz, Integrated IF VCOs with Differential Output General Description Features

... The inductance value required for the desired operating frequency may not necessarily coincide with a standard-value SMT inductor, which typically increases size in ~1.2x steps. In such cases, the inductance must be constructed from two inductors, LF1 and LF2, in order to achieve the desired inducta ...
Second-Stage LC Filter Design
Second-Stage LC Filter Design

... robust and stable under worst case conditions of line, load, and any extra capacitance the user may add. Most two-stage filters are designed in as an afterthought. The converter is finished, but the noise is too high, and there is only room and time to put some small components on the board. This wo ...
Instructions - Klein Tools Europe
Instructions - Klein Tools Europe

... • The VDV Commander will automatically activate the tone generator upon entering the tone generator menu. • Connect your cable to either the RJ45 jack or coax connector located on the top of the VDV Commander. • To switch between network and coax cables, press the coax cable / RJ45 function button ...
Cable Coupler Overview
Cable Coupler Overview

... Ground-check circuits that connect after and disconnect before the phase conductors. Covers which protect against damage and contamination when not in use. ...
User`s Guide Continuity Tester Pro Model CT20
User`s Guide Continuity Tester Pro Model CT20

... FLIR Systems, Inc. warrants this Extech Instruments brand device to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the war ...
Underground Cables Presented By: Er. H.S. Dhaliwal Assistant Professor,
Underground Cables Presented By: Er. H.S. Dhaliwal Assistant Professor,

... These limits are relatively unimportant on overhead lines but will severely limit high voltage underground cable systems  The higher the voltage the shorter the line length must be.  The limiting effects become very important at transmission voltages, especially 100,000 Volts and above.  Limiting ...
MODEL 716 - INCREMENTAL SHAFT ENCODER
MODEL 716 - INCREMENTAL SHAFT ENCODER

... quadrature output. Designed for compatibility with most programmable controllers, electronic counters, motion controllers, and motor drives, it is ideally suited for industrial applications where it is important that the direction of rotation be known. Critical performance specifications for the mos ...
Power System Series Resonance Studies by Modified Admittance
Power System Series Resonance Studies by Modified Admittance

... These methods are primarily suitable for parallel resonance problem with little adaptation to the analysis of series resonance. The reason lies in the close relationship between loop impedance and the occurrence of series resonance. An attempt to apply the modal analysis to series resonance problem ...
Baluns
Baluns

... consisting of two coils of wire connected as shown. • The coils may use an air core or a ferrite core. • Often a current balun is made by winding coaxial cable into a coil, with or without a ferrite core. • The load impedance is not changed by the balun. ...
ELECTROMAGNETIC INDUCTION
ELECTROMAGNETIC INDUCTION

... The induced electric field exists only while the change is occurring. If there is no change, then there is no induction. When there are conductors present, the induced electric field is usually described in terms of an induced voltage, also called the ‘electromotive force’ (EMF). If the conductors f ...
by Hag/M1 6.9%
by Hag/M1 6.9%

... hand position tachometer generator 33 is con tween the delivery and entering speeds of the nected to coil 48 and tachometer generator 34 strip, expressed in feet per minute. is connected to coil 38. Since the actuating coils 41 and 48 are ener If the coil 38 only is energized, the needle M is de?ect ...
Rogowski Coil for Current Measurement in a Cryogenic Environment
Rogowski Coil for Current Measurement in a Cryogenic Environment

... between the current to be measured and the sensing circuit, which is undesirable at deep low temperature. Current sensors based on Faraday effect, like fiber-optic current sensor, are especially useful in high voltage systems because of the inherent electrical isolation, and in systems with high ele ...
Portable Three-Phase Meter Site Source Analyzer
Portable Three-Phase Meter Site Source Analyzer

MAX3815.pdf
MAX3815.pdf

... input data at rates of 250Mbps up to 1.65Gbps (individual channel data rate). It automatically adjusts to attenuation levels of up to 40dB at 825MHz due to skin-effect losses in copper cable. It consists of four CML input buffers, a loss-of-clock signal detector, three independent adaptive equalizer ...
The design of Ruthroff broadband voltage - MARTIN
The design of Ruthroff broadband voltage - MARTIN

... HF antennas. These problems were particularly evident when the transformer was installed at the base of a short vertical, in order to facilitate the use of a remote, coax fed tuner. I wanted to achieve a wide (1 - 55MHz) bandwidth and whilst optimising the antennas found that I had great difficulty ...
Prof. Dr-lng. Konstantin Meyl SCALAR WAVE TECHNOLOGY
Prof. Dr-lng. Konstantin Meyl SCALAR WAVE TECHNOLOGY

... The publishing house has made it to its business, to spread each important discovery or experience with personal denomination of the experimenter in written form. Protocols are delivered in chronological order according to the time of the post office entrance by the publishing house. They can be rea ...
Polycold Fast Cycle Water Vapor Cryopump Installation Customer Instruction Manual
Polycold Fast Cycle Water Vapor Cryopump Installation Customer Instruction Manual

... The display range is –199.9 to +199.9°C and has an accuracy of ±3°C. The temperature meter accepts a type T (copper-constantan) thermocouple input and is powered by the unit’s 24 V(ac) control transformer. The temperature meter provides an analog output from –1.999 to +1.999 V(dc). The output is 0 V ...
MODEL 711 - INCREMENTAL SHAFT ENCODER
MODEL 711 - INCREMENTAL SHAFT ENCODER

Compact FieldPoint Accessories Operating Instructions
Compact FieldPoint Accessories Operating Instructions

... power wires are rated for up to 4 A. Table 2 lists the wire colors that correspond to the 37 pins on the Compact FieldPoint I/O connectors. Signal names in parentheses indicate signals common to all Compact FieldPoint I/O modules. For all other signals, refer to the I/O module operating instructions ...
AI501 – CONTROL MK IV CONNECTOR HOOK UP PROCEDURE
AI501 – CONTROL MK IV CONNECTOR HOOK UP PROCEDURE

... Barrier type glands must be fitted to flexible power and loose filled control cabling entering the connectors to maintain the Exd protection concept and to reduce the potential for core movements within the cable being transferred to the connector’s internal components. Where connectors are terminat ...
Equivalent Circuit and Calculation of Its Parameters of
Equivalent Circuit and Calculation of Its Parameters of

... power source and load is connected to the loop structures, which have not sharp frequency characteristics. The loop structure and the resonant structure is coupled by magnetic induction. A merit of direct fed type is simple structure. On the other hand, indirect type has advantage in freedom of desi ...
< 1 ... 14 15 16 17 18 19 20 21 22 ... 76 >

Loading coil



A loading coil or load coil is an inductor that is inserted into an electronic circuit to increase its inductance. A loading coil is not a transformer to provide coupling to another other circuit. The term originated in the 19th century for inductors used to prevent signal distortion in long-distance telegraph transmission cables. The term is also used for inductors in radio antennas, or between the antenna and its feedline, to make an electrically short antenna resonant at its operating frequency.Loading coils are historically also known as Pupin coils after Mihajlo Pupin, especially when used for the Heaviside condition and the process of inserting them is sometimes called pupinization.The concept of loading coils was discovered by Oliver Heaviside in studying the problem of slow signalling speed of the first transatlantic telegraph cable in the 1860s. He concluded additional inductance was required to prevent amplitude and time delay distortion of the transmitted signal. The mathematical condition for distortion-free transmission is known as the Heaviside condition. Previous telegraph lines were overland or shorter and hence had less delay, and the need for extra inductance was not as great. Submarine communications cables are particularly subject to the problem, but early 20th century installations using balanced pairs were often continuously loaded with iron wire or tape rather than discretely with loading coils, which avoided the sealing problem.