• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Introductory Experiments and Linear Circuits I
Introductory Experiments and Linear Circuits I

... The oscilloscope is the most important instrument in any electronics lab, and in many physics labs as well. To do well in this lab and in later 111 semesters you must be fluent with its operation. Oscilloscopes are used to take a picture of a signal — a time-history or “scope trace” of the amplitude ...
Digital Signal Processing
Digital Signal Processing

... • Advantages of Digital over Analogue Signal Processing: A digital programmable system allows flexibility in reconfiguring the DSP operations simply by changing the program. Reconfiguration of an analogue system usually implies a redesign of hardware, testing and verification that it operates prope ...
NTUST-EE-2013S
NTUST-EE-2013S

... PWM ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... the BIST RAM. In here the inputs are given by the clock directly to the ram module, it acess that inputs if there is any error, it modifies it and then compile that inputs and then after no errors it simulates automatically, for every operation there is both read and write operation, and then simula ...
4. single stage bipolar junction transistor (bjt) amplifiers
4. single stage bipolar junction transistor (bjt) amplifiers

... It is assumed that rb  0, r  , r0   . It is also assumed that all capacitors can be considered to be short circuit at the frequency of operation. The value of the small-signal input resistance is determined by the DC base current r  nVT / I BQ . The transistor small-signal transconductance i ...
RF Solutions - Beholder Europe
RF Solutions - Beholder Europe

... • Internal AGC detector with adjustable take over point (TOP) • 4 MHz reference signal output ...
TPS AutoLearn - Nitrous Express
TPS AutoLearn - Nitrous Express

... The NX TPAS is more durable and contains short circuit protection that other, similar products, do not. The TPAS is designed to work with most domestic and import EFI vehicles. The 15961 is designed to trigger a relay, 1 amp maximum current draw, at or near wide open throttle and automatically calib ...
Lab #5 — Schmitt Trigger and Oscillator Circuit 1 Introduction 2 Pre
Lab #5 — Schmitt Trigger and Oscillator Circuit 1 Introduction 2 Pre

... in the OpAmp which results in an output signal with a duty cycle 6= 50%. The duty cycle can be adjusted by changing the DC reference voltage at the non-inverting terminal of the inverting integrator as shown in Figure 4. (a) Add the variable resistor to your circuit as shown in Figure 4. (b) Adjust ...
iC-NVH 6-bit Sin/D Flash Converter - iC-Haus
iC-NVH 6-bit Sin/D Flash Converter - iC-Haus

... the sine/cosine input signals and the A/B incremental signals generated can be selected here. The device also incorporates an index signal processing circuit which generates a digital zero pulse at Z (gated with A only, respectively B) dependent on the analog sine/cosine input signals and the enable ...
bar graph display ic
bar graph display ic

... arte used in dot mode display at 3 volts, better display can be obtained by increasing the value of programming resistor to 10K. ...
CK series Mid-Priced CMOS IC Time Delay Relay
CK series Mid-Priced CMOS IC Time Delay Relay

... * If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: A dry circuit switch is recommended. A “dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for othe ...
DOC
DOC

... 1. Build the low pass filter circuit shown in . (Remember that the signal generator is connected to ground internally.) 2. Set up CH 1 and CH 2 of the oscilloscope for AC coupling and a x10 probe. Turn off CH 3 and CH 4. Initially set the time base to 20 µsec/div. 3. With the function generator conn ...
Test Procedure for the NCV8853GEVB Evaluation Board
Test Procedure for the NCV8853GEVB Evaluation Board

... 1. Connect a dc input voltage, within the 6.0 V to 36 V range, between VIN and GND 2. Connect a load between VOUT and GND 3. Connect a dc enable voltage, within the 2.0 V to 5.5 V range, between EN/SYNC and GND 4. Optionally, for external clock synchronization, connect a pulse source between EN/SYNC ...
FOUR UA741 QUAD BIPOLAR OPERATIONAL AMPLIFIERS
FOUR UA741 QUAD BIPOLAR OPERATIONAL AMPLIFIERS

... the familiar UA741 operational amplifier. In addition the total supply current for all four amplifiers is compatible to the supply current of a single UA741 type op amp. Other features include input offset current and input bias current which are much less than those of a standard UA741. Also, excel ...
Infrared PWM Transmitter
Infrared PWM Transmitter

... with the information content must be concentrated in a finite range of the frequency spectrum. If the communication link can support the bandwidth associated with a given signal, this ensures that the information content of the signal will be accurately conveyed to receiver without distortion. The s ...
Reliability analysis with isograph
Reliability analysis with isograph

... ADC. There is therefore 8 input monitor and ADC circuits per BLEDP.  The input monitor and the ADC is critical for the operation of both the measurement methods, and is thus critical for one channel in the BLEDP. Therefore, the loss of an ADC is equivalent to the loss of a detector.  The Input Mon ...
Test Equipment for AC/DC Drive and Power Electronic Measurement
Test Equipment for AC/DC Drive and Power Electronic Measurement

... Isolated voltage probes provide another alternative to safe voltage measurements. As the name implies, isolated voltage probes have no direct connection between the measurement probes and the inputs to the scope. The means of isolation is either optical or transformer. This method has a greater comm ...
A differential electrometer for vector electric field
A differential electrometer for vector electric field

... amplifier would form the essential elements of one such electrometer. Several precautions need to be taken while fabricating an electrometer. It is quite likely that the printed circuit board (PCB) material offers low resistance path to the integrated circuit (IC) inputs in case the ICs are soldered ...
digital system for power line frequency measurement
digital system for power line frequency measurement

... fourth second. Therefore, frequency is calculated as an average obtained after exactly 100 periods of 50 Hz power line signal. Afterward, the controller generates new start signal that starts the next counting sequence. The calculated frequency value is represented by 24-bit two's complement value ...
VERS-1 Erin Browning Matthew Mohn Michael Senejoa Motivation
VERS-1 Erin Browning Matthew Mohn Michael Senejoa Motivation

... Unlike all the other components in this build that are controlled by a voltage coming in from another source, this voltage-controlled device is driven by the users input on the controls and not by the guitar. When you have several tones and several frequencies that are all mixing together, harmonics ...
VERS-1 Erin Browning Matthew Mohn Michael Senejoa Motivation
VERS-1 Erin Browning Matthew Mohn Michael Senejoa Motivation

... used only to generate the frequency that is going to be read by the frequency to voltage converter and the envelop is going to be read by the envelop detector to be used by the voltage controlled amplifier. This means that the actual tone of the guitar is not as important other than the envelope and ...
asynchronous analog-discrete converter using an analog signal
asynchronous analog-discrete converter using an analog signal

... are involved, the interface becomes much more complex, being then necessary a way of transforming eletronically the signals from the analog form for the digital one. For this the analog-digital converters (CAD) and the digital-analog converters (DAC) are used. All these architectures possess their a ...


... precision applications will have low input offset voltage at the top of the list. The input offset voltage appears at the output of the amplifier, contributing to the overall system error, but in a photodiode amplifier, it generates additional error. The input offset voltage appears across the photo ...
2 Compensator Emulation
2 Compensator Emulation

...  To learn the basic amplifier circuits for typical phase-lead and phase-lag compensators and design a typical analog phase-lead and phase-lag compensators.  To investigate how signals are passed through the real-time control hardware/software system using D/A and A/D converters.  To replace the a ...
video post processor
video post processor

... pass filter is realized by the post-processing. This gain is realized only when the samples are independent from one and other. Another technique for increasing the resolution of the ADC is by oversampling and using decimation to increase the resolution of the ADC by 1 bit. This requires at least 4x ...
< 1 ... 58 59 60 61 62 63 64 65 66 ... 97 >

Oscilloscope



An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report