Electronics for Analog Signal Processing
... This is called sample data, where the time is discontinuous not continuous it is occurring at regular intervals whereas the amplitude could be any continuous value but taken only during these intervals of time, so this is the sample data. We can do a sort of processing for sample data that is called ...
... This is called sample data, where the time is discontinuous not continuous it is occurring at regular intervals whereas the amplitude could be any continuous value but taken only during these intervals of time, so this is the sample data. We can do a sort of processing for sample data that is called ...
AD7870A: CMOS, Complete, 12-Bit, 100 kHz , Sampling ADC Data Sheet (Rev 0, 02/1992)
... Interrupt, Active low logic output indicating converter status. See timing diagrams. Clock input. An external TTL-compatible clock may be applied to this input pin. Alternatively, tying this pin to VSS enables the internal laser-trimmed clock oscillator. Data Bit 11 (MSB)/High Byte Enable. The funct ...
... Interrupt, Active low logic output indicating converter status. See timing diagrams. Clock input. An external TTL-compatible clock may be applied to this input pin. Alternatively, tying this pin to VSS enables the internal laser-trimmed clock oscillator. Data Bit 11 (MSB)/High Byte Enable. The funct ...
ULTRA SLIMPAK G108-0001 ® DC Powered DC Input Limit Alarm
... input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer flexible setpoint capability. Input voltage spans from 10mV to 200V and input current spans from 1mA to 100mA can be field configured. Bipolar inputs are also accepted. The G ...
... input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer flexible setpoint capability. Input voltage spans from 10mV to 200V and input current spans from 1mA to 100mA can be field configured. Bipolar inputs are also accepted. The G ...
WRT550X Designer Switches
... Off Delay turns Off the circuit(s) one-half, one, or five minutes after switched from On to Off. On Timer keeps On the circuit(s) one-half, one, five, 60, or 120 minutes after the switch is activated to On, after which the circuit(s) are automatically turned Off. ...
... Off Delay turns Off the circuit(s) one-half, one, or five minutes after switched from On to Off. On Timer keeps On the circuit(s) one-half, one, five, 60, or 120 minutes after the switch is activated to On, after which the circuit(s) are automatically turned Off. ...
AD8004
... settling response is obtained by the addition of a small series resistance as shown in Figure 6. The accompanying graph shows the optimum value for RSERIES vs. capacitive load. It is worth noting that the frequency response of the circuit when driving large capacitive loads will be dominated by the ...
... settling response is obtained by the addition of a small series resistance as shown in Figure 6. The accompanying graph shows the optimum value for RSERIES vs. capacitive load. It is worth noting that the frequency response of the circuit when driving large capacitive loads will be dominated by the ...
[PDF]
... complementary input pairs. The difference in random offset voltages of these input pairs translates into a global offset with nonlinear variation over the common mode input range. This nonlinear offset is one of the main causes of large signal distortion in rail-to-rail circuits. To take full advant ...
... complementary input pairs. The difference in random offset voltages of these input pairs translates into a global offset with nonlinear variation over the common mode input range. This nonlinear offset is one of the main causes of large signal distortion in rail-to-rail circuits. To take full advant ...
AD537
... There are two independent adjustments: scale and offset. The first is trimmed by adjustment of the scaling resistor R and the second by the (optional) potentiometer connected to +VS and the VOS pins (“D” package only). Precise calibration requires the use of an accurate voltage standard set to the d ...
... There are two independent adjustments: scale and offset. The first is trimmed by adjustment of the scaling resistor R and the second by the (optional) potentiometer connected to +VS and the VOS pins (“D” package only). Precise calibration requires the use of an accurate voltage standard set to the d ...
Laboratory stand "Electrical Measurements"
... indicates how many counts the digit to the extreme right of the display may vary. So the preceding accuracy example might be stated as ± (1 % + 2). Therefore, for a display reading of 100 volts, the actual voltage would be between 98.8 volts and 101.2 volts. ...
... indicates how many counts the digit to the extreme right of the display may vary. So the preceding accuracy example might be stated as ± (1 % + 2). Therefore, for a display reading of 100 volts, the actual voltage would be between 98.8 volts and 101.2 volts. ...
Schematic
... Plotting the Results of a DC Voltage Sweep and including the results in a word document After your simulation is complete you will see a window with Vo plotted vs V1. In this environment, you can plot voltages, currents and functions of voltages and currents 1) From the main menu in this plotting e ...
... Plotting the Results of a DC Voltage Sweep and including the results in a word document After your simulation is complete you will see a window with Vo plotted vs V1. In this environment, you can plot voltages, currents and functions of voltages and currents 1) From the main menu in this plotting e ...
ADS5204 数据资料 dataSheet 下载
... (1) Integral nonlinearity refers to the deviation of each individual code from a line drawn from zero to full-scale. The point used as zero occurs ½LSB before the first code transition. The full-scale point is defined as a level ½LSB beyond the last code transition. The deviation is measured from th ...
... (1) Integral nonlinearity refers to the deviation of each individual code from a line drawn from zero to full-scale. The point used as zero occurs ½LSB before the first code transition. The full-scale point is defined as a level ½LSB beyond the last code transition. The deviation is measured from th ...
ADC108S102 8-Channel, 500 kSPS to 1 MSPS, 10
... INTEGRAL NON-LINEARITY (INL) is a measure of the deviation of each individual code from a line drawn from negative full scale (½ LSB below the first code transition) through positive full scale (½ LSB above the last code transition). The deviation of any given code from this straight line is measure ...
... INTEGRAL NON-LINEARITY (INL) is a measure of the deviation of each individual code from a line drawn from negative full scale (½ LSB below the first code transition) through positive full scale (½ LSB above the last code transition). The deviation of any given code from this straight line is measure ...
ADS850 数据资料 dataSheet 下载
... See Figure 1 for the circuit example of the most common interface configuration for the ADS850. With the VREF pin connected to the SEL pin, the full-scale input range is defined to be 2Vp-p. This signal is ac-coupled in single-ended form to the ADS850 using the low distortion voltage-feedback amplif ...
... See Figure 1 for the circuit example of the most common interface configuration for the ADS850. With the VREF pin connected to the SEL pin, the full-scale input range is defined to be 2Vp-p. This signal is ac-coupled in single-ended form to the ADS850 using the low distortion voltage-feedback amplif ...
Vocal Harmonizer and Vocoder
... The final design is a simple, fourth-order, "multiple-feedback" bandpass filter. The design was taken from Don Lancaster's Active Filter Cookbook on page 154. The transfer function for a single stage of this filter is straightforward to compute, albeit tedious. The result is -1/R1/C2 * s / (s^2+2/R3 ...
... The final design is a simple, fourth-order, "multiple-feedback" bandpass filter. The design was taken from Don Lancaster's Active Filter Cookbook on page 154. The transfer function for a single stage of this filter is straightforward to compute, albeit tedious. The result is -1/R1/C2 * s / (s^2+2/R3 ...
THS1230 数据资料 dataSheet 下载
... The THS1230 is a CMOS, low-power, 12-bit, 30 MSPS analog-to-digital converter (ADC) that operates with a 3.3-V supply. The THS1230 gives circuit developers complete flexibility. The analog input to the THS1230 is differential with a gain of 0.5 for Mode 2 and 1.0 for Mode 1. The THS1230 provides a w ...
... The THS1230 is a CMOS, low-power, 12-bit, 30 MSPS analog-to-digital converter (ADC) that operates with a 3.3-V supply. The THS1230 gives circuit developers complete flexibility. The analog input to the THS1230 is differential with a gain of 0.5 for Mode 2 and 1.0 for Mode 1. The THS1230 provides a w ...
a Dual CMOS AD7724 -
... This device consists of two seventh order sigma-delta modulators. Each modulator converts its analog input signal into a high speed 1-bit data stream. The part operates from a 5 V power supply and accepts a differential input range of 0 V to +2.5 V or ±1.25 V centered about a common-mode bias. The a ...
... This device consists of two seventh order sigma-delta modulators. Each modulator converts its analog input signal into a high speed 1-bit data stream. The part operates from a 5 V power supply and accepts a differential input range of 0 V to +2.5 V or ±1.25 V centered about a common-mode bias. The a ...
DU-35CLE 4-20mA Process Loop with built-in loop excitation
... For calibration use pins CAL & Input LO to bypass the 24V excitation. The first step is to disengage the ZERO Pot and scale down the Signal Span input to produce the desired Digital Display Span output. Signal Span is defined as the total change of signal input that would be required for a specific ...
... For calibration use pins CAL & Input LO to bypass the 24V excitation. The first step is to disengage the ZERO Pot and scale down the Signal Span input to produce the desired Digital Display Span output. Signal Span is defined as the total change of signal input that would be required for a specific ...
NEMA
... Overrange Indication: .....1 (MSD) displayed with all other digits blank Power Supply (std): .........120/240V AC, 50/60/400 Hz. approx 1.5W. (Optn) VO-DC/ISO ..........Isolated Switcher. 9 to 36V DC/12 to 24V AC (Optn) VO-24V ................Isolated Transformer 24V AC ±10% (Optn) VO-5V DC......... ...
... Overrange Indication: .....1 (MSD) displayed with all other digits blank Power Supply (std): .........120/240V AC, 50/60/400 Hz. approx 1.5W. (Optn) VO-DC/ISO ..........Isolated Switcher. 9 to 36V DC/12 to 24V AC (Optn) VO-24V ................Isolated Transformer 24V AC ±10% (Optn) VO-5V DC......... ...
DG535/536
... The DG535/536 are 16-channel single-ended multiplexers with on-chip address logic and control latches. The multiplexer connects one of sixteen inputs (S1, S2 through S16) to a common output (D) under the control of a 4-bit binary address (A0 to A3). The specific input channel selected for each addre ...
... The DG535/536 are 16-channel single-ended multiplexers with on-chip address logic and control latches. The multiplexer connects one of sixteen inputs (S1, S2 through S16) to a common output (D) under the control of a 4-bit binary address (A0 to A3). The specific input channel selected for each addre ...
AD7367 数据手册DataSheet下载
... mode and conversion is initiated. If CONVST is low at the end of a conversion, the part goes into powerdown mode. In this case, the rising edge of CONVST will instruct the part to power up again. ...
... mode and conversion is initiated. If CONVST is low at the end of a conversion, the part goes into powerdown mode. In this case, the rising edge of CONVST will instruct the part to power up again. ...
Analog Dialogue 30-4
... the area of the plates, V is the voltage across the capacitor, and d is the distance between the plates. In normal operation, the fixed fingers on either side of the force fingers are at the same voltage potential as the beam and its fingers. With no voltage between the force fingers on the beam and ...
... the area of the plates, V is the voltage across the capacitor, and d is the distance between the plates. In normal operation, the fixed fingers on either side of the force fingers are at the same voltage potential as the beam and its fingers. With no voltage between the force fingers on the beam and ...
PICASSO - Soundstream
... 3. Input Overload Indicators - Indicates the signal input level or input gain level is too high channels 1 & 2. 4. Input Level Selector Switch - Selectable input sensitivity range from 0.2-2 Volts RMS, or from 0.5-5 Volts RMS - channels 1 & 2. 5. Left Channel Balanced / Unbalanced Input Selector Swi ...
... 3. Input Overload Indicators - Indicates the signal input level or input gain level is too high channels 1 & 2. 4. Input Level Selector Switch - Selectable input sensitivity range from 0.2-2 Volts RMS, or from 0.5-5 Volts RMS - channels 1 & 2. 5. Left Channel Balanced / Unbalanced Input Selector Swi ...
AD7813 数据手册DataSheet下载
... When used in its power-down mode, the AD7813 automatically powers down at the end of a conversion and powers up at the start of a new conversion. This feature significantly reduces the power consumption of the part at lower throughput rates. The AD7813 can also operate in a high speed mode where the ...
... When used in its power-down mode, the AD7813 automatically powers down at the end of a conversion and powers up at the start of a new conversion. This feature significantly reduces the power consumption of the part at lower throughput rates. The AD7813 can also operate in a high speed mode where the ...
701933 Current Probe User`s Manual
... • To avoid shorting or bodily injury when opening the tip of the sensor head or when performing measurement, if the conductor under measurement exceeds the safety voltage level (when measurement exceeds 300 V), make sure the conductor under measurement has basic insulation that satisfies measurement ...
... • To avoid shorting or bodily injury when opening the tip of the sensor head or when performing measurement, if the conductor under measurement exceeds the safety voltage level (when measurement exceeds 300 V), make sure the conductor under measurement has basic insulation that satisfies measurement ...
Stability and accuracy of active shielding for grounded capacitive sensors Ferran Reverter
... the other hand, Cp ideally does not affect the measurement of Cx because both cable conductors are at the same potential. Therefore, in principle, this technique solves the drawbacks of passive shielding. However, due to the parasitic components of the coaxial cable, the buffer amplifier has a posit ...
... the other hand, Cp ideally does not affect the measurement of Cx because both cable conductors are at the same potential. Therefore, in principle, this technique solves the drawbacks of passive shielding. However, due to the parasitic components of the coaxial cable, the buffer amplifier has a posit ...
Oscilloscope
An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.