AD9221/AD9223/AD9220 Complete 12
... amplifier (SHA) is equally suited for both multiplexed systems that switch full-scale voltage levels in successive channels as well as sampling single-channel inputs at frequencies up to and beyond the Nyquist rate. Also, the AD9221/AD9223/AD9220 is well suited for communication systems employing Di ...
... amplifier (SHA) is equally suited for both multiplexed systems that switch full-scale voltage levels in successive channels as well as sampling single-channel inputs at frequencies up to and beyond the Nyquist rate. Also, the AD9221/AD9223/AD9220 is well suited for communication systems employing Di ...
ADCMP608 (Rev. 0)
... equivalent. For large fanouts, buses, or transmission lines, use an appropriate buffer to maintain the excellent speed and stability of the comparator. With the rated 15 pF load capacitance applied, more than half of the total device propagation delay is output stage slew time. Because of this, the ...
... equivalent. For large fanouts, buses, or transmission lines, use an appropriate buffer to maintain the excellent speed and stability of the comparator. With the rated 15 pF load capacitance applied, more than half of the total device propagation delay is output stage slew time. Because of this, the ...
LT1168 - Low Power, Single Resistor Gain Programmable, Precision Instrumentation Amplifier
... as low as 2k. The LT1168 is laser trimmed for very low input offset voltage (40µV max), drift (0.3µV/°C), high CMRR (90dB, G = 1) and PSRR (103dB, G = 1). Low input bias currents of 250pA max are achieved with the use of superbeta processing. The output can handle capacitive loads up to 1000pF in an ...
... as low as 2k. The LT1168 is laser trimmed for very low input offset voltage (40µV max), drift (0.3µV/°C), high CMRR (90dB, G = 1) and PSRR (103dB, G = 1). Low input bias currents of 250pA max are achieved with the use of superbeta processing. The output can handle capacitive loads up to 1000pF in an ...
BDTIC T D A 5 2 2 1
... signal is representing the demodulated signal with low frequencies applied to the demodulator demodulated to logic ones and high frequencies demodulated to logic zeroes. However this is only valid in case the local oscillator is low-side injected to the mixer which is applicable to receive frequenci ...
... signal is representing the demodulated signal with low frequencies applied to the demodulator demodulated to logic ones and high frequencies demodulated to logic zeroes. However this is only valid in case the local oscillator is low-side injected to the mixer which is applicable to receive frequenci ...
Eddystone Broadcast ---- XE35/75/150/300 Series 35
... enables this control and monitoring to be performed remotely via an RS232 or TCP/IP serial interface. The module is microprocessor based with a back illuminated, high contrast 4 line by 20 character display and separate ‘MOD(ulation)’, ‘SYSTEM NORMAL’ and ‘MUTE’ red/green indicators. A robust, seale ...
... enables this control and monitoring to be performed remotely via an RS232 or TCP/IP serial interface. The module is microprocessor based with a back illuminated, high contrast 4 line by 20 character display and separate ‘MOD(ulation)’, ‘SYSTEM NORMAL’ and ‘MUTE’ red/green indicators. A robust, seale ...
AC Electricity - UniMAP Portal
... • Able to define the terms peak and peak-to-peak as they apply to AC sinusoidal waveforms. • Able to convert between peak and peak-to-peak values. • Able to describe the meaning of root-mean-square (RMS) as it applies to AC sinusoidal waveforms. • Able to convert between RMS values and peak values. ...
... • Able to define the terms peak and peak-to-peak as they apply to AC sinusoidal waveforms. • Able to convert between peak and peak-to-peak values. • Able to describe the meaning of root-mean-square (RMS) as it applies to AC sinusoidal waveforms. • Able to convert between RMS values and peak values. ...
LTC6405
... Note 4: The LTC6405C/LTC6405I are guaranteed functional over the operating temperature range –40°C to 85°C. Note 5: The LTC6405C is guaranteed to meet specified performance from 0°C to 70°C. The LTC6405C is designed, characterized, and expected to meet specified performance from –40°C to 85°C but is n ...
... Note 4: The LTC6405C/LTC6405I are guaranteed functional over the operating temperature range –40°C to 85°C. Note 5: The LTC6405C is guaranteed to meet specified performance from 0°C to 70°C. The LTC6405C is designed, characterized, and expected to meet specified performance from –40°C to 85°C but is n ...
TS2DDR2811 数据资料 dataSheet 下载
... The TS2DDR2811 is a 8-channel single-pole single-throw (SPST) signal switch capable of switching signals with bandwidth in excess of 1 GHz. The device includes a select pin (SEL) that is used to select any 1 of the 8 channel inputs. This select pin controls the data path of the SPST switch. The devi ...
... The TS2DDR2811 is a 8-channel single-pole single-throw (SPST) signal switch capable of switching signals with bandwidth in excess of 1 GHz. The device includes a select pin (SEL) that is used to select any 1 of the 8 channel inputs. This select pin controls the data path of the SPST switch. The devi ...
AD8132 (Rev. G)
... The AD8132 is also used as a differential driver for the transmission of high speed signals over low cost twisted pair or coaxial cables. The feedback network can be adjusted to boost the high frequency components of the signal. The AD8132 is used for either analog or digital video signals or for ot ...
... The AD8132 is also used as a differential driver for the transmission of high speed signals over low cost twisted pair or coaxial cables. The feedback network can be adjusted to boost the high frequency components of the signal. The AD8132 is used for either analog or digital video signals or for ot ...
Navy Electricity and Electronics Training Series
... understand the information. The subject matter reflects day-to-day requirements and experiences of personnel in the rating or skill area. It also reflects guidance provided by Enlisted Community Managers (ECMs) and other senior personnel, technical references, instructions, etc., and either the occu ...
... understand the information. The subject matter reflects day-to-day requirements and experiences of personnel in the rating or skill area. It also reflects guidance provided by Enlisted Community Managers (ECMs) and other senior personnel, technical references, instructions, etc., and either the occu ...
DOEPFER System A-100 Synthesizer Voice A-111
... filter goes into self-oscillation. In this mode it behaves like a sine wave oscillator, and can be used as an alternative sound source. A detailed description of the resonance function can be found in the user manuals of the A-100 filter modules (e.g. A-120 or A-121). As the control scale of the VCF ...
... filter goes into self-oscillation. In this mode it behaves like a sine wave oscillator, and can be used as an alternative sound source. A detailed description of the resonance function can be found in the user manuals of the A-100 filter modules (e.g. A-120 or A-121). As the control scale of the VCF ...
FEATURES APPLICATION DIAGRAM
... When PDREF is low, the internal reference and buffer are enabled, producing 4.096 V on this pin. When PDREF is high, the internal reference and buffer are disabled, allowing an externally supplied voltage reference up to 5.0 V. Decoupling is required with or without the internal reference and buffer ...
... When PDREF is low, the internal reference and buffer are enabled, producing 4.096 V on this pin. When PDREF is high, the internal reference and buffer are disabled, allowing an externally supplied voltage reference up to 5.0 V. Decoupling is required with or without the internal reference and buffer ...
16-Bit, 500 kSPS PulSAR ADC in MSOP/QFN AD7686
... Convert Input. This input has multiple functions. On its leading edge, it initiates the conversions and selects the interface mode, chain, or CS. In CS mode, it enables the SDO pin when low. In chain mode, the data should be read when CNV is high. Serial Data Output. The conversion result is output ...
... Convert Input. This input has multiple functions. On its leading edge, it initiates the conversions and selects the interface mode, chain, or CS. In CS mode, it enables the SDO pin when low. In chain mode, the data should be read when CNV is high. Serial Data Output. The conversion result is output ...
Isolated, Shunt-Based Current Sensing
... constraint and invoking the Nyquist-Shannon sampling theorem, the input passive filter must allow all signals below 35 kHz to pass freely into the AMC1304 input. The upper bound on the filter's cutoff frequency depends on the inherent characteristics of the AMC1304M25 analog front end. According to ...
... constraint and invoking the Nyquist-Shannon sampling theorem, the input passive filter must allow all signals below 35 kHz to pass freely into the AMC1304 input. The upper bound on the filter's cutoff frequency depends on the inherent characteristics of the AMC1304M25 analog front end. According to ...
basics of electrical circuits laboratory
... How to use the oscilloscope 1. When the oscilloscope’s ON-OFF switch is in OFF position, FOCUS and INTENSITY indicators should be pointing low levels. 2. The indicators for adjusting vertical and horizontal positions should be pointing a level around the middle. 3. The EXT button, which is used for ...
... How to use the oscilloscope 1. When the oscilloscope’s ON-OFF switch is in OFF position, FOCUS and INTENSITY indicators should be pointing low levels. 2. The indicators for adjusting vertical and horizontal positions should be pointing a level around the middle. 3. The EXT button, which is used for ...
User`s Guide
... 1.Turning on the instrument: Press the power key on the front panel to turn on the power. After displaying “WELCOME” for 2 seconds and model number such as “PROTEK 9340” for 1 second in flashing manner. The instrument will enter into “standard waveforms” function state according the turning-on setti ...
... 1.Turning on the instrument: Press the power key on the front panel to turn on the power. After displaying “WELCOME” for 2 seconds and model number such as “PROTEK 9340” for 1 second in flashing manner. The instrument will enter into “standard waveforms” function state according the turning-on setti ...
THS1041 数据资料 dataSheet 下载
... references to match the user’s design requirements. For more design flexibility, the internal reference can be bypassed to use an external reference to suit the dc accuracy and temperature drift requirements of the application. The out-of-range output indicates any out-of-range condition in THS1041’ ...
... references to match the user’s design requirements. For more design flexibility, the internal reference can be bypassed to use an external reference to suit the dc accuracy and temperature drift requirements of the application. The out-of-range output indicates any out-of-range condition in THS1041’ ...
AD8309 数据手册DataSheet 下载
... references. Note that (1) is mathematically incomplete in representing the behavior of a demodulating log amp such as the AD8309, where VIN has an alternating sign. However, the basic principles are unaffected. ...
... references. Note that (1) is mathematically incomplete in representing the behavior of a demodulating log amp such as the AD8309, where VIN has an alternating sign. However, the basic principles are unaffected. ...
MAX1146–MAX1149 Multichannel, True-Differential, Serial, 14-Bit ADCs General Description
... are software configurable for unipolar/bipolar and single-ended/differential operation. The 4-wire serial interface connects directly to SPI™/QSPI™/MICROWIRE™ devices without external logic. The serial strobe output (SSTRB) allows convenient connection to digital signal processors. The MAX1146–MAX11 ...
... are software configurable for unipolar/bipolar and single-ended/differential operation. The 4-wire serial interface connects directly to SPI™/QSPI™/MICROWIRE™ devices without external logic. The serial strobe output (SSTRB) allows convenient connection to digital signal processors. The MAX1146–MAX11 ...
AM Tuners for Car Radios and Home Stereos Overview
... The wideband AGC circuit two-signal sensitivity and shortwave interference suppression characteristics have been achieved by reducing the sensitivity by approximately 10 dB from that of previous devices. If a FET with low gm and high IDSS is used, the sensitivity can be increased by increasing the e ...
... The wideband AGC circuit two-signal sensitivity and shortwave interference suppression characteristics have been achieved by reducing the sensitivity by approximately 10 dB from that of previous devices. If a FET with low gm and high IDSS is used, the sensitivity can be increased by increasing the e ...
EV10AS180AGS Low power L-Band 10-bit 1.5 GSps ADC
... The EV10AS180A works in fully differential mode from analog inputs up to digital outputs. It operates in the first Nyquist and L-Band (Fin ranging from DC to 1800 MHz). DEMUX Ratio (1:1 or 1:2 or 1:4) can be selected with the 2 pins RS0, RS1. DEMUX outputs are synchronous on each port. A differentia ...
... The EV10AS180A works in fully differential mode from analog inputs up to digital outputs. It operates in the first Nyquist and L-Band (Fin ranging from DC to 1800 MHz). DEMUX Ratio (1:1 or 1:2 or 1:4) can be selected with the 2 pins RS0, RS1. DEMUX outputs are synchronous on each port. A differentia ...
Linear and Digital IC Applications - ECM
... 1. An ideal op-amp draws no current at both the input terminals I.e. I1 = I2 = 0. Thus its input impedance is infinite. Any source can drive it and there is no loading on the driver stage 2. The gain of an ideal op-amp is infinite, hence the differential input Vd = V1 – V2 is essentially zero for th ...
... 1. An ideal op-amp draws no current at both the input terminals I.e. I1 = I2 = 0. Thus its input impedance is infinite. Any source can drive it and there is no loading on the driver stage 2. The gain of an ideal op-amp is infinite, hence the differential input Vd = V1 – V2 is essentially zero for th ...
ADC10D020 Dual 10-Bit, 20 MSPS, 150 mW A/D Converter (Rev. D)
... high, placing the converter into a low power state where it typically consumes less than 1 mW and from which recovery is less than 1 ms. Bringing the STBY (Standby) pin high places the converter into a standby mode where power consumption is about 27 mW and from which recovery is 800 ns. The ADC10D0 ...
... high, placing the converter into a low power state where it typically consumes less than 1 mW and from which recovery is less than 1 ms. Bringing the STBY (Standby) pin high places the converter into a standby mode where power consumption is about 27 mW and from which recovery is 800 ns. The ADC10D0 ...
Light dimmer lab document
... Work at either a lab bench, or on top of one of the black cabinet tops. Never place the hot tip of a soldering iron on the surface of a lab bench or table. Instead, use the coiled wire holster. Do your soldering on a wood piece, or using a Panavise. Remember to use safety glasses. Use #16 stranded w ...
... Work at either a lab bench, or on top of one of the black cabinet tops. Never place the hot tip of a soldering iron on the surface of a lab bench or table. Instead, use the coiled wire holster. Do your soldering on a wood piece, or using a Panavise. Remember to use safety glasses. Use #16 stranded w ...
Oscilloscope

An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.