J.M. Rivas, Y. Han, O. Leitermann, A.D. Sagneri, and D.J. Perreault, A High-Frequency Resonant Inverter Topology with Low Voltage Stress,” IEEE Transactions on Power Electronics , Vol. 23, No. 4, pp. 1759-1771, July 2008.
... in the drain-source voltage waveform, yielding a quasi-trapezoidal drain-source voltage having a low peak value. More details about the relationship between impedance and waveform shaping may be found in [3] and [28]. The components of the inverter are tuned to obtain a voltage across the switch wit ...
... in the drain-source voltage waveform, yielding a quasi-trapezoidal drain-source voltage having a low peak value. More details about the relationship between impedance and waveform shaping may be found in [3] and [28]. The components of the inverter are tuned to obtain a voltage across the switch wit ...
4.5V to 18V Input Voltage, 3A/2A/2A Output Current Triple
... The TPS65261, TPS65261-1 features an automatic power sequence with connecting MODE pin to V7V and configuring EN1/2/3 pins. The device also features an open drain RESET signal to monitor power down. At light load, the TPS65261 automatically operates in pulse skipping mode (PSM) and the TPS65261-1 op ...
... The TPS65261, TPS65261-1 features an automatic power sequence with connecting MODE pin to V7V and configuring EN1/2/3 pins. The device also features an open drain RESET signal to monitor power down. At light load, the TPS65261 automatically operates in pulse skipping mode (PSM) and the TPS65261-1 op ...
Switching, Operation/ Display and Control Devices
... As of the mid-1990s, the Internet and PCs started to become popular, and society had arrived at an advanced information age. At high-voltage electric distribution facilities, in order to prevent service loss in advanced information systems, the power supply stability and reliability must be improve ...
... As of the mid-1990s, the Internet and PCs started to become popular, and society had arrived at an advanced information age. At high-voltage electric distribution facilities, in order to prevent service loss in advanced information systems, the power supply stability and reliability must be improve ...
Major Project Guidelines
... requirement phasing of the project, through a DEWA approved consultant and contractor. However, DEWA requires adequate lead time for arranging 132kV cables to any new 132kV substations after finalization of load requirements, substation locations, cable corridors and receiving the original affection ...
... requirement phasing of the project, through a DEWA approved consultant and contractor. However, DEWA requires adequate lead time for arranging 132kV cables to any new 132kV substations after finalization of load requirements, substation locations, cable corridors and receiving the original affection ...
TDA8947J 4-channel audio amplifier
... The TDA8947J contains two types of detection sensors: one measures local temperatures of the power stages and one measures the global chip temperature. At a local temperature of approximately 185 °C or a global temperature of approximately 150 °C, this detection circuit switches off the power stages ...
... The TDA8947J contains two types of detection sensors: one measures local temperatures of the power stages and one measures the global chip temperature. At a local temperature of approximately 185 °C or a global temperature of approximately 150 °C, this detection circuit switches off the power stages ...
ups glups - Powerstar Inc
... Power factor is a quantity which has important implications when sizing a UPS system. Power is a measure of the delivery rate of energy and in DC (direct current) electrical circuits is expressed as the mathematical product of Volts and Amps (Power = Volts x Amps). However, in AC (alternating curren ...
... Power factor is a quantity which has important implications when sizing a UPS system. Power is a measure of the delivery rate of energy and in DC (direct current) electrical circuits is expressed as the mathematical product of Volts and Amps (Power = Volts x Amps). However, in AC (alternating curren ...
High Voltage Products
... further course of opening, this increased pressure initiates a gas flow through the nozzle (3), extinguishing the arc. In this case, the arc energy is used to interrupt the fault current. This energy needs not be provided by the operating mechanism. Major features: • Self-compression interrupter un ...
... further course of opening, this increased pressure initiates a gas flow through the nozzle (3), extinguishing the arc. In this case, the arc energy is used to interrupt the fault current. This energy needs not be provided by the operating mechanism. Major features: • Self-compression interrupter un ...
High average power fundamental input couplers for the Cornell
... Figure 6: Waveguide windows: a) LEDA window [9]; b) Jefferson Lab FEL window [12]. The major drawback of these coupler designs as well as many others is that windows are located outside cryostats and therefore must be attached after the cryostat assembly. This makes possibility of cavity contaminati ...
... Figure 6: Waveguide windows: a) LEDA window [9]; b) Jefferson Lab FEL window [12]. The major drawback of these coupler designs as well as many others is that windows are located outside cryostats and therefore must be attached after the cryostat assembly. This makes possibility of cavity contaminati ...
Fuse Facts and Numbering System
... soldered joint gets hot enough to melt and the spring shears the junction loose. Under short circuit conditions, the short circuit element operates to open the circuit. All dual-element fuses are considered to be slow blow but not all slow blow fuses are dual-element. Slow-blow fuses are ideal for c ...
... soldered joint gets hot enough to melt and the spring shears the junction loose. Under short circuit conditions, the short circuit element operates to open the circuit. All dual-element fuses are considered to be slow blow but not all slow blow fuses are dual-element. Slow-blow fuses are ideal for c ...
Insights_into_MCU_Mixed_Signal_Design - Renesas e
... Charge/discharge gate with a small constant current Reduces slew rate which improves EMI ...
... Charge/discharge gate with a small constant current Reduces slew rate which improves EMI ...
4.5V to 18V Input Voltage, 3A/2A/2A Output Current Triple
... The TPS65261, TPS65261-1 features an automatic power sequence with connecting MODE pin to V7V and configuring EN1/2/3 pins. The device also features an open drain RESET signal to monitor power down. At light load, the TPS65261 automatically operates in pulse skipping mode (PSM) and the TPS65261-1 op ...
... The TPS65261, TPS65261-1 features an automatic power sequence with connecting MODE pin to V7V and configuring EN1/2/3 pins. The device also features an open drain RESET signal to monitor power down. At light load, the TPS65261 automatically operates in pulse skipping mode (PSM) and the TPS65261-1 op ...
STANDARDIZATION OF THE SUPPORTING AND INSTALLATION OF GENERATOR CABLES Ville Tamssi
... idea needs an internal operation system that is based on standard. Business standards have an essential role when setting targets for control systems. Standards have to be easy to change flexibly and target-orientedly according to growth strategies. By using internal standards productivity and motiv ...
... idea needs an internal operation system that is based on standard. Business standards have an essential role when setting targets for control systems. Standards have to be easy to change flexibly and target-orientedly according to growth strategies. By using internal standards productivity and motiv ...
analysis and simulation of the p&o mppt algorithm
... (PV) array model is used to obtain the transfer function of the electronic converter and to design a voltage compensator for the converter input voltage. A buck converter is used in this work. Keywords – maximum power point, MPPT, PV, photovoltaic, perturb, observe. I. Introduction A photovoltaic (P ...
... (PV) array model is used to obtain the transfer function of the electronic converter and to design a voltage compensator for the converter input voltage. A buck converter is used in this work. Keywords – maximum power point, MPPT, PV, photovoltaic, perturb, observe. I. Introduction A photovoltaic (P ...
Wind turbine power generation emulation via doubly fed induction
... Supply-side circuits are electrically coupled with back-to-back (DFIG-side and Supplyside) Space Vector Modulators (SVMs) that are coupled through a DC Link consisting of a capacitor bank. The back-to-back SVMs, with DC Link, provide bi-directional power flow between the DFIG rotor and Supply-side p ...
... Supply-side circuits are electrically coupled with back-to-back (DFIG-side and Supplyside) Space Vector Modulators (SVMs) that are coupled through a DC Link consisting of a capacitor bank. The back-to-back SVMs, with DC Link, provide bi-directional power flow between the DFIG rotor and Supply-side p ...
Technical Requirements for Subsea High Voltage Direct
... *Cable too long -> most of the AC current needs to charge/discharge cable capacitor Two ways to reduce/eliminate transmission loss are: ...
... *Cable too long -> most of the AC current needs to charge/discharge cable capacitor Two ways to reduce/eliminate transmission loss are: ...
Single-Phase to Three-Phase Power Converters: State of the Art
... Notice that Enjeti et al. [45], [46] propose five new configurations, but just two of them will be presented in this section due to the dc-link midpoint connection; the other ones will be shown in Section II-A2. The topology in Fig. 7, in spite of reducing the number of power switches dramatically—c ...
... Notice that Enjeti et al. [45], [46] propose five new configurations, but just two of them will be presented in this section due to the dc-link midpoint connection; the other ones will be shown in Section II-A2. The topology in Fig. 7, in spite of reducing the number of power switches dramatically—c ...
(Dynamic) Voltage (Frequency)
... Process Variation or Process Strength Process variation, or process strength, is the variation in the attributes of integrated transistors when a semiconductor device is fabricated. This phenomenon occurs on all semiconductor devices from all manufacturers. This process is more relevant for smaller ...
... Process Variation or Process Strength Process variation, or process strength, is the variation in the attributes of integrated transistors when a semiconductor device is fabricated. This phenomenon occurs on all semiconductor devices from all manufacturers. This process is more relevant for smaller ...
Speed of Line Protection – Can We Break Free of Phasor
... communicate end to end for communications-based line protection. Fast relays, by their nature, respond to high-frequency signal components, which brings additional benefits. Consider nontraditional sources (such as wind and solar). These sources have no inertia and are connected to the power system ...
... communicate end to end for communications-based line protection. Fast relays, by their nature, respond to high-frequency signal components, which brings additional benefits. Consider nontraditional sources (such as wind and solar). These sources have no inertia and are connected to the power system ...
P84399
... special precautions to assure electrical noise immunity (e.g. audio crosstalk). NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inte ...
... special precautions to assure electrical noise immunity (e.g. audio crosstalk). NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inte ...
BM6203FS
... The input threshold voltages of the control pins are 2.5V and 0.8V, with a hysteresis voltage of approximately 0.4V. The IC will accept input voltages up to the VCC voltage. When the same phase control pins are input high at the same time, the high side and low side gate driver outputs become low. D ...
... The input threshold voltages of the control pins are 2.5V and 0.8V, with a hysteresis voltage of approximately 0.4V. The IC will accept input voltages up to the VCC voltage. When the same phase control pins are input high at the same time, the high side and low side gate driver outputs become low. D ...
Old Company Name in Catalogs and Other Documents
... subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be d ...
... subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be d ...
Electric power system

An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.