• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Embedded Solutions Through Targeted Power Conditioning
Embedded Solutions Through Targeted Power Conditioning

... momentary outage event. 2. Open the motor contactor upon event detection. 3. Keep any motor control center associated with the protected motor “alive” during the event. 4. Once the event has ended, re-close the motor contactor at the appropriate time, preventing torque and current spikes. 5. Can be ...
User Manual Rev. 01a
User Manual Rev. 01a

... related parts around Are they correct? these two amplifiers ...
Dual-Feed Rear Output Circuit Breaker Panel
Dual-Feed Rear Output Circuit Breaker Panel

AC Power Switch
AC Power Switch

AN AUTOMATIC LINE VOLTAGE SWITCHING CIRCUIT
AN AUTOMATIC LINE VOLTAGE SWITCHING CIRCUIT



a two stage isolated bidirectional dc/dc convertor for pv
a two stage isolated bidirectional dc/dc convertor for pv

... iLrp starts to flow through the body diode of M2, and the ON state of the body diode of M3 is maintained to provide the current path of iLrs. When M2 and M4 are turned on at t4, ZVS of M2 is accomplished, and iLrs flows through the channel ofM4 and Cr. After t5, iLrp changes its direction, flowing t ...
Target Tracking Slides
Target Tracking Slides

Avcom Satellite/Microwave Accessories
Avcom Satellite/Microwave Accessories

... a wider feedhorn beam pattern for efficient dish illumination. The PFA12 is a modification to increase the beam width of standard DBS LNBs. The PFA-12 is comprised of a length of circular waveguide and a scalar ring attached to one end of the waveguide. The dimensions are such that it can be dropped ...
ZZ013748752
ZZ013748752

... failure or a mis-operation of end user equipments. Utility distribution networks, sensitive industrial loads and critical commercial operations suffer from various types of outages and service interruptions which can cost significant financial losses. With the restructuring of power systems and with ...
A Novel Control Method for Unified Power Quality Conditioner
A Novel Control Method for Unified Power Quality Conditioner

... This paper describes a new control strategy used in the UPQC system, which mainly compensate reactive power and voltage and current harmonics in the load under non-ideal mains voltage and unbalanced load current conditions. The proposed control strategy use only loads and mains voltage measurements ...
1	 Description
1 Description

... • When replacing batteries or connecting an external power supply, first turn OFF the power to the circuit under measurement. Then, remove the input lead from the circuit under measurement. ...
The First Attenuator - Altair PW-5
The First Attenuator - Altair PW-5

... • This unit was a little better than the Altair. It uses banks of graduated resistors to dissipate load. This is identical to modern attenuator circuit design. It works better than the Altair, but users reported liability issues such as: 1. Not very road worthy, solder would melt from heat, the load ...
Semester VII - Suruchi Academy
Semester VII - Suruchi Academy

... experiments on PLC. The experiments should be based on Case Study. Practical Work :15 marks Test (at least one) :10 marks The final certification and acceptance of term-work ensures the satisfactory performance of practical work and minimum passing in the term-work. Suggested List of experiment to b ...
thpma046
thpma046

... 2. Network N4 offers constant output voltage as well as in-phase source voltage and current under all loading conditions but at different operating frequencies. Therefore, depending on operating point either good voltage regulation or minimum reactive power can be achieved. Besides, the network uses ...
R32125132
R32125132

... In short circuit studies, it is necessary to have the knowledge of pre-fault voltages and currents. These pre-fault conditions can be obtained from the results of load flow studies by the NewtonRaphson iteration method. The Newton-Raphson method is adopted due to quadratic convergence of bus voltage ...
Aalborg Universitet
Aalborg Universitet

... different machine models of DFIG for some papers. For example, an 8th-order generator model is derived in [2]. A 3rd-order, 5th-order and 8th-order models are built and compared in [3] for the transient performance studies, the results have shown there may be a few discrepancy with different detaile ...
Lecture04 - madalina
Lecture04 - madalina

... Due to a different number of factors (technological factors, reduced costs etc) the real values of the parameters are near to the rated (target) values. By the selective measurements, the manufacturers offers only those components which have the parameters in the some specific limits around the rate ...
How to reduce 3rd harmonics with ST6200C motor control software
How to reduce 3rd harmonics with ST6200C motor control software

... - nominal voltages up to 240V, single-phase, two or three wire; - nominal voltages up to 415V, three-phase, three or four wire; 1.2 OBJECTIVE The objective of this standard is to give the general requirements and the maximum permissible values of the harmonic components of the input current which ma ...
Looking for
Looking for

... - Mains to Battery Transfer time less than 10 ms - Supports Crest Factor of 3:1 - Minimum Power Factor (leading/lagging) of 0.65 - Fault indications - USB Communication with PC - LCD front panel ...
Digital QRP SWR/ Power Meter
Digital QRP SWR/ Power Meter

Industrial Power System Design in a Utility Environment
Industrial Power System Design in a Utility Environment

... The second type consists of 2,400-Vac, 1,000 hp, four- of economics. For a utility, downtime is simply loss of revpole, three-phase, squirrel-cage induction motors serving enue from the sale of electricity. For the industrial user, reciprocating compressors. Synchronous machines were downtime result ...
DC Regulated Power Supply
DC Regulated Power Supply

... supply, which is designed with 230V, 1-phase, 50Hz AC mains. The AC input voltage is fed to the primary of an air-cooled transformer and the secondary is rectified by full wave bridge rectifier and filtered by electrolytic capacitors. This filtered DC link is fed to a transistor as series element fo ...
Telegonos_manual
Telegonos_manual

... but with certain power limitations. The optimal efficiency is achieved with about 1.5 Ohm. The battery holder is powered up by consecutive fast pressing of the button for 1 to 5 times, see extended functions menu (Oc “On clicks”). With continued pressing of the button the user steps through the prog ...
design and simulation of shunt active power filter
design and simulation of shunt active power filter

... PQ standards (IEEE-519/1992) have specified the limits on the THD of currents and voltages that a user of power electronics equipment and other nonlinear loads is allowed to inject into the utility system. The harmful effects of harmonic distortion [6] are not known until failure occurs because thes ...
< 1 ... 295 296 297 298 299 300 301 302 303 ... 561 >

Electric power system



An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report