• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Design and Implementation of Carrier Based Sinusoidal PWM
Design and Implementation of Carrier Based Sinusoidal PWM

... MOSFETs or IGBTs, self commutation with base or gate drive signals for their controlled turn-on and turn-off. A ...
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP

... BBNPP transmission lines will utilize one new on-site corridor and the on-site SusquehannaRoseland corridor for interconnections to the existing offsite power transmission grid as shown in Figure 8.2-1. The two circuits are supported on separate structures, which are located to minimize the likeliho ...
II. Space vector modulation for csc
II. Space vector modulation for csc

... supply the dc motor directly. If converter switching frequency is limited to relatively small value which cannot ensure constant dc link current during switching period, there can be additional inductance in series with the motor. Shown converter is one-quadrant drive because it cannot provide dc li ...
SGA9089Z 数据资料DataSheet下载
SGA9089Z 数据资料DataSheet下载

... ESD Rating - Human Body Model (HBM) ...
STANDARD REVIEW PLAN
STANDARD REVIEW PLAN

... Management System (ADAMS), at http://www.nrc.gov/reading-rm/adams.html, under Accession # ML100740246. ...
Electromagnetic Transients Simulation Models for Accurate
Electromagnetic Transients Simulation Models for Accurate

... several microseconds. The parameters of these equations are derivable from the pre- and post-switching voltages, currents and other physical data. The energy loss can then be calculated analytically (not numerically!) by integrating the product of developed voltage and current equations resulting in ...
HIGH-LEVEL MULTI-STEP INVERTER OPTIMIZATION, USING A
HIGH-LEVEL MULTI-STEP INVERTER OPTIMIZATION, USING A

... Even updated PWM techniques used to control modern static converters such as machine drives, power factor compensators or active power filters, do not produce perfect waveforms, which strongly depend on the semiconductors switching frequency. Normally, with voltage or current converters, as they gen ...
Document
Document

... The Earth wire is there to protect you. ...
FSQ0765RS Green-Mode Fairchild Power Switch (FPS™) for Quasi-Resonant Operation -
FSQ0765RS Green-Mode Fairchild Power Switch (FPS™) for Quasi-Resonant Operation -

... current source is disabled. The FPS continues its normal switching operation and the power is supplied from the auxiliary transformer winding unless VCC goes below the stop voltage of 8V. VDC ...
EEE-PP-004 - 2027
EEE-PP-004 - 2027

... rectifying diode should be reduced. To solve this reverse recovery problem, various soft-switching techniques using additional passive or active snubber circuits have been proposed [12]–[16]. However, those methods require relatively large number of passive or active components which increase the pr ...
High voltage capacitor banks
High voltage capacitor banks

Aalborg Universitet Smart Inverters for Utility and Industry Applications
Aalborg Universitet Smart Inverters for Utility and Industry Applications

... of control architectures, autonomous, adaptive, functionally scalable and plug-and-play subsystems are highly desired to reduce the requirements of control and communications and to relieve the system operation burden. A holon, as described by Arthur Koestler in 1967, is a part-whole system, with an ...
Project code STCU/5388. Development, realisation and testing of the sample... phase shift transformer with thyristor control. Period of realisation 2011-2012....
Project code STCU/5388. Development, realisation and testing of the sample... phase shift transformer with thyristor control. Period of realisation 2011-2012....

Comparison Study of Maximum Power Point Tracker Techniques for
Comparison Study of Maximum Power Point Tracker Techniques for

... to the problem. The harnessing of solar energy using PV modules comes with its own problems that arise from the change in insulation conditions. These changes in insulation conditions severely affect the efficiency and output power of the PV modules[1-3].A great deal of research has been done to imp ...
Genetic Algorithm Based Pole Placement Controller for
Genetic Algorithm Based Pole Placement Controller for

... In an important member of the FACTS controllers’ family, Static Synchronous Compensator (STATCOM) has been at the centre of attention. STATCOM is a shunt-connected device that is used to provide reactive power compensation to a transmission line. Through regulation of the line voltage at the point o ...
Comparison of cost and efficiency of DC versus AC in
Comparison of cost and efficiency of DC versus AC in

... It has been known for a long time that direct current (DC) is potentially more convenient, in terms of efficiency, in the transmission of electrical energy than three-phase current and, a fortiori, singlephase current. Losses that occur in cables are potentially lower for DC than AC, because the cab ...
II 777 HVR P2 B Installation Instructions
II 777 HVR P2 B Installation Instructions

... drawing 2-800 amps (external CTs required for >90FLA systems). The 777-HVR-P2 can be safely programmed prior to installation by supplying power with a 9V battery. See Figure 4 in the PROGRAMMING section. DO NOT connect the battery to the unit when line voltage is present. The 777-HVR-P2 cannot be te ...
Aalborg Universitet Asymmetrical Grid Fault Ride-Through Strategy of Three-phase Grid-connected
Aalborg Universitet Asymmetrical Grid Fault Ride-Through Strategy of Three-phase Grid-connected

... With the high penetration of grid-connected renewable energy systems, the new grid codes or standards such as IEEE P1547.8 have been drafted [1], where the fault ride through (FRT) is a mandatory function. In order to meet the grid code requirements, a significant contribution made by Rodriguez, et ...
Dorman Smith
Dorman Smith

... engine generator applications, the Generator Set Controller range offers products for basic levels of control, through to sophisticated multifunctional products offering automated engine starting, stopping, transfer switching, protection, control and metering. ...
iW656 Product Summary - Dialog Semiconductor
iW656 Product Summary - Dialog Semiconductor

... with CC1/CC2 pins for MD attach/detach detection. The iW656 also integrates a high current charge-pump circuit to drive an external NFET VBUS switch. The iW656 resides on the secondary side of an AC/DC power supply and negotiates voltage and current settings depending on the requests from the MD. Th ...
- VS Technologies
- VS Technologies

... of passive elements. With the development of fast acting selfcommutating switches, pulse width modulated (PWM) voltage source inverter (VSI)-based static reactive power compensators (STATCOMs) [12]–[18] have been evolved. These STATCOMbased voltage regulators exhibit better dynamic performance and t ...
Capacitors for Power Factor Correction
Capacitors for Power Factor Correction

...  Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After ≤ 90 seconds the voltage between the terminals must decline to less than 75 V.  Check the temperature of capacitors directly after operation for a longer period, but m ...
Historical Summary of the Labrador-Island HVdc System (1974-Present)
Historical Summary of the Labrador-Island HVdc System (1974-Present)

... The systems analyses allowed for the identification of required Island upgrades including the conversion of Holyrood units to synchronous condensers, the installation of five combustion turbines at the Pipers Hole, the installation of one (plus one spare) 300 MVAR high-inertia synchronous condenser ...
Investigation of Polarization and Depolarization Current for
Investigation of Polarization and Depolarization Current for

UM1016
UM1016

< 1 ... 157 158 159 160 161 162 163 164 165 ... 561 >

Electric power system



An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report