
TPS2010A 数据资料 dataSheet 下载
... The TPS201xA family of power distribution switches is intended for applications where heavy capacitive loads and short circuits are likely to be encountered. These devices are 50-mΩ N-channel MOSFET high-side power switches. The switch is controlled by a logic enable compatible with 5-V logic and 3- ...
... The TPS201xA family of power distribution switches is intended for applications where heavy capacitive loads and short circuits are likely to be encountered. These devices are 50-mΩ N-channel MOSFET high-side power switches. The switch is controlled by a logic enable compatible with 5-V logic and 3- ...
PDF
... converter commutation count, and hence its switching losses. Also presented in Section IV is two sets of higher level control schemes with the first used for controlling one set of three-phase outputs so as to compensate for harmonic currents, reactive power flow and three-phase unbalance caused by ...
... converter commutation count, and hence its switching losses. Also presented in Section IV is two sets of higher level control schemes with the first used for controlling one set of three-phase outputs so as to compensate for harmonic currents, reactive power flow and three-phase unbalance caused by ...
Evaluates: MAX8822 MAX8822 Evaluation Kit General Description Features
... Note: Indicate that you are using the MAX8822 when contacting these component suppliers. ...
... Note: Indicate that you are using the MAX8822 when contacting these component suppliers. ...
technical manual (PDF 59k)
... size and type of alternator and should not normally require adjustment. If, however, under operational conditions it is found that the SCOOP function is frequently re-~- ting in loss of alternator output, without any apparent cause,,,-it may be necessary to adjust the voltage at which SCOOP operates ...
... size and type of alternator and should not normally require adjustment. If, however, under operational conditions it is found that the SCOOP function is frequently re-~- ting in loss of alternator output, without any apparent cause,,,-it may be necessary to adjust the voltage at which SCOOP operates ...
Complete Paper
... components and cooling devices usually occupy a much larger space than semiconductor devices in power electronics building block. It is well known that when many DGs are connected to utility grids, they can cause problems such as voltage rise and protection problem in the utility grid. To solve thes ...
... components and cooling devices usually occupy a much larger space than semiconductor devices in power electronics building block. It is well known that when many DGs are connected to utility grids, they can cause problems such as voltage rise and protection problem in the utility grid. To solve thes ...
The utilization of synthetic inertia from wind farms and its
... deals with how it has been carried in a model presented by GE through the so-called ‘synthetic inertia’ support. The report also provides the optimum control parameters data for tuning the ‘synthetic inertia’ controller. ...
... deals with how it has been carried in a model presented by GE through the so-called ‘synthetic inertia’ support. The report also provides the optimum control parameters data for tuning the ‘synthetic inertia’ controller. ...
the brochure
... include constant voltage or constant current with automatic crossover. In addition, the Model 250V offers a constant power operating mode. Operation may be timed or continuous. All parameters, including voltage, current, power (250V model) and time are easily set using the membrane keypad and displa ...
... include constant voltage or constant current with automatic crossover. In addition, the Model 250V offers a constant power operating mode. Operation may be timed or continuous. All parameters, including voltage, current, power (250V model) and time are easily set using the membrane keypad and displa ...
AC Sources - Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS
... performed to reestablish OPERABILITY provided an assessment determines the safety of the plant is maintained or enhanced. Credit may be taken for unplanned events that satisfy this SR. 2. ] If performed with EDG synchronized with offsite power, it shall be performed at a power factor ≤ 0.9. However, ...
... performed to reestablish OPERABILITY provided an assessment determines the safety of the plant is maintained or enhanced. Credit may be taken for unplanned events that satisfy this SR. 2. ] If performed with EDG synchronized with offsite power, it shall be performed at a power factor ≤ 0.9. However, ...
atwinc1500 - Atmel Corporation
... functions. Alternatively, ATWINC1500A allows for an external 32kHz clock to be used for this purpose, which is provided through Pin 24 (RTC_CLK). Software selects whether the internal clock or external clock is used. The internal low-power clock is ring-oscillator based and has accuracy within 10,00 ...
... functions. Alternatively, ATWINC1500A allows for an external 32kHz clock to be used for this purpose, which is provided through Pin 24 (RTC_CLK). Software selects whether the internal clock or external clock is used. The internal low-power clock is ring-oscillator based and has accuracy within 10,00 ...
Sensorless Control for a Switched Reluctance Wind Generator
... possible to estimate the inductance at any rotational speed. In this paper, the method has been experimentally demonstrated for a speed range between 0 and 1500 rpm. Another contribution of the developed method consists in the use of an NN to approximate the function that relates saturated inductanc ...
... possible to estimate the inductance at any rotational speed. In this paper, the method has been experimentally demonstrated for a speed range between 0 and 1500 rpm. Another contribution of the developed method consists in the use of an NN to approximate the function that relates saturated inductanc ...
Mini MegaPAC User Guide
... voltage is needed, upgrading is easy: simply unlock a single screw and replace the slidein ConverterPAC assembly with one of the same length and has the desired voltage power rating. For additional flexibility, ConverterPACs can be connected in parallel to increase output power (booster ConverterPAC ...
... voltage is needed, upgrading is easy: simply unlock a single screw and replace the slidein ConverterPAC assembly with one of the same length and has the desired voltage power rating. For additional flexibility, ConverterPACs can be connected in parallel to increase output power (booster ConverterPAC ...
XL250-3,5,6 Product Specification
... power or whenever the power supply’s longevity is threatened by excessive loads or temperatures. It will provide the host system with advanced warning of an impending shutdown whenever one of these conditions occurs. To minimize acoustic noise, the microcontroller can turn a 12V fan on or off based ...
... power or whenever the power supply’s longevity is threatened by excessive loads or temperatures. It will provide the host system with advanced warning of an impending shutdown whenever one of these conditions occurs. To minimize acoustic noise, the microcontroller can turn a 12V fan on or off based ...
Advances in Natural and Applied Sciences
... Theories and definitions of Transformers: Transformers are called for in a simple language and prototype device consists of two sets of primary and secondary windings square and surrounding magnetic sheets of iron core transformers. Transformers are called for in a simple language and prototype devi ...
... Theories and definitions of Transformers: Transformers are called for in a simple language and prototype device consists of two sets of primary and secondary windings square and surrounding magnetic sheets of iron core transformers. Transformers are called for in a simple language and prototype devi ...
Atmel LED Driver-MSL3082
... video frame-by-frame LED string intensity control for up to 16 interconnected devices, allowing active area dimming when used for video displays. The advanced PWM engine synchronizes with the video signal, and offers phase shifted string drive, virtually eliminating waterfall noise and motion blur. ...
... video frame-by-frame LED string intensity control for up to 16 interconnected devices, allowing active area dimming when used for video displays. The advanced PWM engine synchronizes with the video signal, and offers phase shifted string drive, virtually eliminating waterfall noise and motion blur. ...
AP358 LOW POWER DUAL OPERATIONAL AMPLIFIERS Description
... inputs, and remain in the linear mode with an input common-mode voltage of 0 VDC. These amplifiers operate over a wide range of power supply voltage with little change in performance characteristics. At 25°C amplifier operation is possible down to a minimum supply voltage of 2.3 VDC. Precautions sho ...
... inputs, and remain in the linear mode with an input common-mode voltage of 0 VDC. These amplifiers operate over a wide range of power supply voltage with little change in performance characteristics. At 25°C amplifier operation is possible down to a minimum supply voltage of 2.3 VDC. Precautions sho ...
BDTIC www.BDTIC.com/infineon Driving Mid Power LEDs from
... series in front of the LED drivers, resulting in a certain voltage drop of the LEDs, reducing the voltage at the enable pin below 25V. A digital input pin (BCR321U) allows dimming via a Microcontroller with frequencies of up to 10 kHz. A reduction of the output current at higher temperatures is the ...
... series in front of the LED drivers, resulting in a certain voltage drop of the LEDs, reducing the voltage at the enable pin below 25V. A digital input pin (BCR321U) allows dimming via a Microcontroller with frequencies of up to 10 kHz. A reduction of the output current at higher temperatures is the ...
Diapositive 1
... inverter dominated architecture have been investigated. Detailed results of testing a three phase microgrid with three grid forming units (one diesel 16 kW and two battery units 12 kW each), a wind generator 15 kVA and several photovoltaic generators, have been studied. Normal and emergency microgri ...
... inverter dominated architecture have been investigated. Detailed results of testing a three phase microgrid with three grid forming units (one diesel 16 kW and two battery units 12 kW each), a wind generator 15 kVA and several photovoltaic generators, have been studied. Normal and emergency microgri ...
High-Frequency AC-Link PV Inverter
... these problems. Reference [5] introduces a transformerless topology in which the ground leakage current is minimized; however, the voltage cannot change over a wide range. Reference [9] proposes an integrated solution for a PV/FCbased hybrid distributed generation system to eliminate the requirement ...
... these problems. Reference [5] introduces a transformerless topology in which the ground leakage current is minimized; however, the voltage cannot change over a wide range. Reference [9] proposes an integrated solution for a PV/FCbased hybrid distributed generation system to eliminate the requirement ...
Why is a transformer needed?
... A three phase transformer must be selected so that any one phase is not overloaded. Each phase should have the additional 1 KVA rating required by the heater even though the heater will operate on one phase only. So, the transformer should have a minimum KVA rating of 2.8 + 1 + 1 + 1 or 5.8 KVA. A 6 ...
... A three phase transformer must be selected so that any one phase is not overloaded. Each phase should have the additional 1 KVA rating required by the heater even though the heater will operate on one phase only. So, the transformer should have a minimum KVA rating of 2.8 + 1 + 1 + 1 or 5.8 KVA. A 6 ...
Electric power system

An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.