• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ex3-7A-o-can
ex3-7A-o-can

... • Location of Access Points: • You may not be able to simply draw coverage area circles and drop them over a plan. • Do access points use existing wiring? • Position access points: • Above obstructions. • Vertically near the ceiling in the center of each coverage area, if possible. • In locations wh ...
Chapter 8 Power Supplies
Chapter 8 Power Supplies

... © 2010 The McGraw-Hill Companies, Inc. All rights reserved ...
nWP006 RF Performance Test Guidelines
nWP006 RF Performance Test Guidelines

... The general guidelines presented in this document are complemented by device specific application notes that give a brief guide on how to run the various tests on our different radio devices (nRF family). Performance tests must be conducted on more than one unit to avoid misleading conclusions. Runn ...
7050TX-48
7050TX-48

... Increased adoption of 10 Gigabit Ethernet servers coupled with applications using higher bandwidth is accelerating the need for dense 10 and 40 Gigabit Ethernet switching. The 7050TX Series support from 32 to 96 ports of auto-negotiating 100Mb/1Gb/10GBASE-T and from 4 to 12 ports of 10/40GbE that al ...
THCD-100 - Teledyne Hastings Instruments
THCD-100 - Teledyne Hastings Instruments

... etc.). As such it may be necessary for the channel to be re-zeroed by the user. The user re-zero function is provided for this task. It simply takes the current reading (sampled and averaged over 3 seconds) and uses that as an additional offset for the channel in question, subtracting the value from ...
FTT-10A Free Topology Twisted Pair Transceiver
FTT-10A Free Topology Twisted Pair Transceiver

... The FTT-10A transceiver also provides electrical isolation for I/O devices that are grounded, allowing such devices to be used on a link power network segment. Each segment of a link power network utilizes a non-isolated design with a single ground point at the LPI-10 Link Power Interface. Proper op ...
StrainBook/616 - Measurement Computing
StrainBook/616 - Measurement Computing

... for an external voltage source. The unit includes wide gain ranges and filter selection which make it an excellent general purpose or high gain amplifier for other transducer inputs. Up to 8 input signals attach to the unit, each via a DB9 connector on the front panel. Each channel has an independen ...
PowerLogic PM1000 Series Power Meters User Manual
PowerLogic PM1000 Series Power Meters User Manual

... This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment ge ...
DA100 Data Acquisition Unit
DA100 Data Acquisition Unit

... enables you to easily connect subunits to the main unit with a twisted pair cable. The availability of a wide variety of modules combined with the simple, readily adaptable construction, enables the configuration of the DA100 to be easily and quickly changed or expanded in order to meet changes in t ...
LVDS, CML, ECL-differential interfaces with odd
LVDS, CML, ECL-differential interfaces with odd

... National developed and offered many industry firsts in LVDS which included FPD Link, Channel-Link, Military grade LVDS and even the first stand-alone line driver / receiver standard products. ...
S. Lim, J. Ranson, D.M. Otten and D.J. Perreault, Two-Stage Power Conversion Architecture Suitable for Wide Range Input Voltage, IEEE Transactions on Power Electronics , Vol. 30, No. 2, pp. 805-816, Feb. 2015.
S. Lim, J. Ranson, D.M. Otten and D.J. Perreault, Two-Stage Power Conversion Architecture Suitable for Wide Range Input Voltage, IEEE Transactions on Power Electronics , Vol. 30, No. 2, pp. 805-816, Feb. 2015.

installation, start-up and adjustment manual
installation, start-up and adjustment manual

... The transfer switch shipped with this generator is enclosed in a NEMA 1 enclosure. This type of enclosure is intended for indoor use only. Follow these rules: ...
New Breed of Network Fault-Tolerant Voltage-Source
New Breed of Network Fault-Tolerant Voltage-Source

... Aberdeen, Aberdeen, AB24 3UE U.K. (e-mail: [email protected]). Color versions of one or more of the figures in this paper are available online at http://ieeexplore.ieee.org. Digital Object Identifier 10.1109/TPWRS.2012.2199337 ...
Passive Online Rogue Access Point Detection Using Sequential
Passive Online Rogue Access Point Detection Using Sequential

... point using 11 Mbps 802.11b or 54 Mbps 802.11g. In both the Ethernet and WLAN settings, the router’s queues for incoming data packets and ACKs are modeled as M/D/1 queues. Let QD and QA denote the queues for data and ACKs respectively. The utilizations of QD and QA are ρD and ρA , respectively. We a ...
Media Access Control #7
Media Access Control #7

FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER CCNPP Unit 3
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER CCNPP Unit 3

... The U.S. EPR FSAR includes the following COL Item in Section 8.1.1: A COL applicant that references the U.S. EPR design certification will provide site-specific information describing the interface between the offsite transmission system, and the nuclear unit, including switchyard interconnections. ...
MP2607 - Monolithic Power System
MP2607 - Monolithic Power System

... The IN of MP2607 can accept voltage as high as 13V, thus allows the use of low cost high output ripple adapters. ...
Table Of Contents
Table Of Contents

... that are plugged directly into an AC receptacle to recharge. • Certain battery chargers for battery packs used in hand power tools. These chargers will have a warning label stating that dangerous voltages are present at the charger’s battery terminals. The power, or “wattage”, rating of AC appliance ...
DSM3 for XM3 Technical Manual - Alpha XM3
DSM3 for XM3 Technical Manual - Alpha XM3

... 5.1.3 Upgrading Manually by Setting SNMP Parameters..................................................................................49 5.1.4 Upgrading via the DOCSIS Configuration File..........................................................................................49 ...
an electrothermally-driven low voltage micro switch for high
an electrothermally-driven low voltage micro switch for high

UFC 3-550-03FA Electrical Power Supply and Distribution
UFC 3-550-03FA Electrical Power Supply and Distribution

... planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD(AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other custom ...
A Power Delivery Network Aware Framework for Synthesis of 3D
A Power Delivery Network Aware Framework for Synthesis of 3D

... distribution grid for a 3D-mesh CMP with VIs. We address the PDN design problem for the global grid, where each grid-node supplies to a core in the 3D mesh and VRMs are integrated to scale down voltage to cores in VIs. Besides overheads of chip area and power dissipation of the VRM components, prope ...
BU21024FV-M
BU21024FV-M

Chapter 1 AN OVERVIEW OF HARMONICS MODELING AND
Chapter 1 AN OVERVIEW OF HARMONICS MODELING AND

... dedicated three-phase distribution feeders it is generally sufficient to model two transformations from the load point. Generally, transformer impedances dominate. Branch circuits should be modeled if they connect to power factor correction capacitors or motors. Although capacitance of overhead line ...
N.A. Sales Training Telcom Overview - ESET-Wiki
N.A. Sales Training Telcom Overview - ESET-Wiki

... Design Notes: Protection Application: The power bus of the battery pack should be protected against an overcurrent runaway condition of the Li-ion cell, as well as from ESD. The control line (e.g. SMBus, I2C, etc.) may also need to be protected against ESD. These are all low voltage (<6VDC) circuits ...
< 1 ... 86 87 88 89 90 91 92 93 94 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.