• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Unit 3
Unit 3

... Ground: The ground or “return” wire ...
Latex 3000 Printer Series Site Preparation Guide
Latex 3000 Printer Series Site Preparation Guide

... Power Supply (UPS). The UPS must be rated to meet the power requirements of the printer, and should be in accordance with the wiring standards of the country of installation. The printer requires the following electrical components to be supplied and installed by the customer, according to the Elect ...
Circus 2.0 IRC User Manual Rev. 1
Circus 2.0 IRC User Manual Rev. 1

... Always connect the product to a grounded circuit to avoid the risk of electrocution. Always disconnect the product from the power source before cleaning or replacing the fuse. Avoid direct eye exposure to the light source while the product is on. Make sure the power cord is not crimped or damaged. N ...
DRAFT REGULATORY GUIDE DG-1172 DRAFT REGULATORY GUIDE
DRAFT REGULATORY GUIDE DG-1172 DRAFT REGULATORY GUIDE

... the capability to (1) start and accelerate a number of large motor loads in rapid succession, while maintaining voltage and frequency within acceptable limits, (2) provide power promptly to engineered safety features if a loss of offsite power and a design-basis event occur during the same time peri ...
Aalborg Universitet Generation Systems With Battery Energy Storage
Aalborg Universitet Generation Systems With Battery Energy Storage

... Mode III: Vdc_ref= Vdc_n=200V. In this mode, the system operates with connection to AC grid through bi-directional DC/AC converters. The DC bus voltage is regulated by the DC/AC converters through inversion, which means the generated PV power is greater than the local load demands. The modular DC/DC ...
ADS7830 数据资料 dataSheet 下载
ADS7830 数据资料 dataSheet 下载

... with lower LSB size. With a 2.5V reference, the internal noise of the converter typically contributes only 0.02LSB peak-topeak of potential error to the output code. When the external reference is 50mV, the potential error contribution from the internal noise will be 50 times larger—1LSB. The errors ...
5300 Series TECSource User's Manual
5300 Series TECSource User's Manual

... The front panel is designed for simplicity in operation. There are three buttons on the front panel: Output, Menu, and the adjustment knob. The Output button is used to turn the output on and off. Whenever the output is on, the blue Output On LED will be lit. The Menu button is used to enter the TEC ...
Limits of Scaling MOSFETs
Limits of Scaling MOSFETs

MultyMass MMC2 - badger meter europa gmbh
MultyMass MMC2 - badger meter europa gmbh

... General information and notes for the reader Read these instructions carefully prior to installing and commissioning the device. These instructions are an important part of the product and must be kept for later use. These instructions are intended as an overview and do not contain detailed informat ...
Date_umn_0130M_15283 - University of Minnesota
Date_umn_0130M_15283 - University of Minnesota

... I am very thankful to my lab mates Boram Lee and Chia-Lin Hu for their invaluable help throughout my research. Last but not the least; I would like to thank my parents for their love and support. Without them none of this would have ever been possible. ...
Butler - e:cue
Butler - e:cue

... The data which is saved to the Butler is thus exactly the same that you would have if you recorded the output of the e:cue Programmer on a DMX output device in live mode. During export, the actual DMX data of the show is rendered and compressed - analogous to creating MP3 files from a CD. One conseq ...
A Single Dc Source Based Cascaded H-Bridge 5
A Single Dc Source Based Cascaded H-Bridge 5

R.C.N. Pilawa-Podgurski, D. Giuliano, and D.J. Perreault, “Merged Two-Stage Power Converter Architecture with Soft Charging Switched-Capacitor Energy Transfer,” 2008 IEEE Power Electronics Specialists Conference , June 2008, pp. 4008 – 4015
R.C.N. Pilawa-Podgurski, D. Giuliano, and D.J. Perreault, “Merged Two-Stage Power Converter Architecture with Soft Charging Switched-Capacitor Energy Transfer,” 2008 IEEE Power Electronics Specialists Conference , June 2008, pp. 4008 – 4015

TBU-DT085-100-WH
TBU-DT085-100-WH

... reduce the current to a quiescent current level within a period of time that is dependent upon the applied voltage. After the surge, the TBU® device resets when the voltage across the TBU® device falls to the Vreset level. The TBU® device will automatically reset on lines which have no DC bias or ha ...
Industrial Automation www.infineon.com/automation
Industrial Automation www.infineon.com/automation

harmonics-shipboard-reportdraft1final
harmonics-shipboard-reportdraft1final

... Table 1 Recommended limit for distortion indices ......................................................................................................... 9 Table 2 Summary of the impact of harmonics on electric equipment ........................................................................... 12 ...
The Products - BEC Distribution
The Products - BEC Distribution



TBU-DT085-300-WH Datasheet
TBU-DT085-300-WH Datasheet

... reduce the current to a quiescent current level within a period of time that is dependent upon the applied voltage. After the surge, the TBU® device resets when the voltage across the TBU® device falls to the Vreset level. The TBU® device will automatically reset on lines which have no DC bias or ha ...
Low Power Multiplication Algorithm for Switching Activity Reduction
Low Power Multiplication Algorithm for Switching Activity Reduction

... (a 0 + 1) instead of a 0 , which requires a simple modification to the logic to generate the corresponding (n+1) PPs. Tables 1 and 2 give the total number of PPs and the average number of ones in PPs with and without MASAR. The numbers for MASAR are after PP reduction in Step 2. Figure 4 shows an ex ...
BASIS 922az User Manual
BASIS 922az User Manual

ASCO 7000 Series SUGGESTED SPECIFICATION for Automatic
ASCO 7000 Series SUGGESTED SPECIFICATION for Automatic

... before the load is transferred. C. Auxiliary contacts, rated 10 amps, 250 VAC shall be provided consisting of one contact, closed when the ATS is connected to the normal source and one contact closed, when the ATS is connected to the emergency source. D. LED indicating lights (16 mm industrial grade ...
VXR-7000 - Vertex Standard
VXR-7000 - Vertex Standard

ACS Stepper Hardware & Installation User Guide
ACS Stepper Hardware & Installation User Guide

Stresa, Italy, 26-28 April 2006 SCALING EFFECTS FOR
Stresa, Italy, 26-28 April 2006 SCALING EFFECTS FOR

< 1 ... 75 76 77 78 79 80 81 82 83 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report