• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Operating experience with a generator stator end
Operating experience with a generator stator end

Transient Voltage Surge Suppression
Transient Voltage Surge Suppression

Aalborg Universitet SYSTEMS Choi, Uimin
Aalborg Universitet SYSTEMS Choi, Uimin

... systems consist of various components, and among them, power semiconductor devices are one of the most fragile components. Thus, they play a key role in the robustness and reliability of the overall power electronic systems. Insulated Gate Bipolar Transistor (IGBT) power modules are the most widely ...
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems

... grid voltage fluctuations. The normal NPSS alignment has each NAT powering two of the four NPSS trains. In the event of a NAT failure, the affected trains are fasttransferred to the other functioning NAT with minimum voltage decay and frequency difference to limit motor torque during the transfer. T ...
High-Speed Board Design Advisor: Pinout Definition
High-Speed Board Design Advisor: Pinout Definition

... If VREFB pins are not used, designers should connect them to either the VCCIO in the bank in which the pin resides or GND. They cannot be used as generic I/Os. Banks 9 through 12 are enhanced PLL external clock output banks. These PLL banks utilize the adjacent VREFB group when voltage-referenced st ...
750kVA SG Series UPS with eBoost Technology
750kVA SG Series UPS with eBoost Technology

... provided that the bypass AC power source is within the specified frequency range. The rectifier/charger shall convert the normal AC input power to DC power for the inverter and for charging the battery. ...
Banner OMNI-BEAM Photoelectric Sensors
Banner OMNI-BEAM Photoelectric Sensors

... OMNI-BEAM is a modular self-contained sensor. It is made up of a sensor head and a power block; an optional plug-in timing logic module may be added easily. The three modular components, sold separately, simply plug and bolt together — without interwiring — to create a complete self-contained photoe ...
Theory of Operation
Theory of Operation

... The VSS+DC has a unique, patented active magnetic levitation system that fully levitates the flywheel-rotating group, allowing the flywheel to rotate without any physical contact. This has a number of advantages over mechanical bearing systems: A. Reduced drag: Mechanical bearings induce drag propor ...
Modeling of Package and Board Power Distribution Networks Using
Modeling of Package and Board Power Distribution Networks Using

... Future systems require a larger number of integrated circuits (ICs), more input/output (I/O) connections, and faster operating clock frequencies with low cost, high performance, high functionality, and high reliability. In addition, the next generation of electronic products is becoming more mixed s ...
ADM698 数据手册DataSheet 下载
ADM698 数据手册DataSheet 下载

Introduction to Power Electronics
Introduction to Power Electronics

DM-111S Current Data Logger Product Manual
DM-111S Current Data Logger Product Manual

PSoC® 4 Hardware Design Considerations
PSoC® 4 Hardware Design Considerations

Before You Begin: Assign Information Classification
Before You Begin: Assign Information Classification

...  Wireless devices connect to access points within a specified area.  Access points connect to the network using copper cabling. ...
PDF
PDF

... When you use the autoconfiguration profile in GIR mode, the system checks for supported protocols and adds them to the configuration profile. When you enter GIR (maintenance) mode, the system automatically generates a profile in which all supported protocols are shut down. In addition, the autoconfi ...
Time Varying Harmonic Currents from Large Penetration Electronic
Time Varying Harmonic Currents from Large Penetration Electronic

... magnitude spectrum variability for the different operation points evidenced in Fig. 16. In particular, the harmonic spectrum relevant to the different points reveals even significant differences both in magnitude and in pattern terms. Figure 15 permits evidence the differences between ink-jet and la ...
PDF
PDF

... (LTE) traffic, tunneling small cells and femtocells, Unlicensed Mobile Access (UMA) and Generic Access Networks (GANs), and third-generation (3G) and fourth-generation (4G) macro cell voice and data traffic over fixed broadband networks back to the mobile operator’s core network. The increase in 3G ...
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems

... The main generator provides power through the station switchyard to the transmission system via an isolated phase bus (IPB) system and three single-phase main step-up transformers (MSU). Incoming power to the onsite AC power system is from the station switchyard during all modes of plant operation, ...
MIS framework
MIS framework

... IEEE 802.21 presentation release statements This document has been prepared to assist the IEEE 802.21 Working Group. It is offered as a basis for discussion and is not binding on the contributing individual(s) or organization(s). The material in this document is subject to change in form and conten ...
e Shar k®100 & 100T Electro Industries/GaugeTech Installation & Operation Manual
e Shar k®100 & 100T Electro Industries/GaugeTech Installation & Operation Manual

ge energy - GE Industrial Solutions
ge energy - GE Industrial Solutions

PDF
PDF

... capacitors (C1,C2,C40) provide a dc bus voltage. A linear regulator (U13) provides tightly regulated 12V for the power supply PWM ic. Page 2 of the schematic “Isolated Flyback Power Supply” contains the control and power stages for the flyback converter. The PWM ic (U2) operates in open loop mode wi ...
Uses for TPS cables
Uses for TPS cables

... You should maintain adequate clearances from other services so that maintenance to their systems will not interfere with your cables. Another practice you should avoid is installing cables above rafters. The Wiring Rules Clause 3.9.4.4 prohibits installation of cables in any space formed between roo ...
Statistical Modeling of Leakage in Nano-CMOS Circuits - Mos-AK
Statistical Modeling of Leakage in Nano-CMOS Circuits - Mos-AK

CAT853 - 3-Pin Microprocessor Power Supply
CAT853 - 3-Pin Microprocessor Power Supply

... The CAT853, CAT863, CAT859, and CAT869 are supervisory circuits that monitor power supplies in digital systems. These devices generate a reset signal, which is asserted while the power supply voltage is below a preset threshold level and for at least 140 ms after the power supply level has risen abo ...
< 1 ... 33 34 35 36 37 38 39 40 41 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report