• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... All the relevant parameters are given in Appendix. The source voltages of 13.8kV are connected by a 290km transmission line through three-phase step-up transformers. The system consists of two output voltage of transformer is 500KV equivalents, respectively 1000MVA and 4200MVA in each area, connecte ...
Coordination of Active and Reactive Distributed
Coordination of Active and Reactive Distributed

... devices can be easily employed as actuators of load curtailment control actions (AMR devices already receive a signal that can limit load capacity, as done for example for insolvent customers). Cleary, all above mentioned techniques can be implemented only if an extensive set of real-time measuremen ...
Product and functional description Application program Bus mode
Product and functional description Application program Bus mode

... consumers independently of each other. The connection to the bus line can be carried out either via a bus terminal block or by a contacting system to a data-rail installed in the DIN-rail. ...
Power System Verification During Accelerated Life Testing
Power System Verification During Accelerated Life Testing

... to 30 separate voltages and 10 currents can be measured using a Fusion device. The designer does not need to run wires outside of a thermal chamber for voltage measurements and does not need to add wire loops for attaching current probes. This approach also eliminates errors due to noise induced on ...
Evaluation and Implementation of a Shunt Active Power Filter under
Evaluation and Implementation of a Shunt Active Power Filter under

... harmonic distortion was reduced, but single harmonics were not completely eliminated. On the other hand, Sasaki and Machida theorized that harmonics could be eliminated by using the principle of magnetic flux compensation. This in principle is the use of current to produce a flux to counteract the f ...
$doc.title

... Motorola reserves the right to make changes without further notice to any products herein. Motorola makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Motorola assume any liability arising out of the application or use of any ...
Power Factor and Grid-Connected Photovoltaics
Power Factor and Grid-Connected Photovoltaics

... reactive power is either under or over supplied, the voltage on the network may rise or fall to a point where generators must switch off to protect themselves thereby decreasing the generation and cause further problems. As can be seen from the phase diagram, increasing the reactive power increases ...
PE3503 - Peregrine Semiconductor
PE3503 - Peregrine Semiconductor

... waveguide above ground plane model with trace width of 0.030”, trace gaps of 0.007”, dielectric thickness of 0.028”, metal thickness of 0.0014” and εr of 4.4. Note that the predominate mode for these transmission lines is coplanar waveguide. J2 provides DC power to the device. Starting from the lowe ...
A Scalable, Reconfigurable, and Efficient Data Center Power
A Scalable, Reconfigurable, and Efficient Data Center Power

... • New circuits can be added or changed on a live system safely • No under-floor cables needed • All circuits monitored for power • All breaker status remotely monitored • IT zones and associated power distribution can be deployed over time • All power levels supported using only a single cable to th ...
The Design and Testing of an Automatic RF Conditioning System for
The Design and Testing of an Automatic RF Conditioning System for

Experiment 9
Experiment 9

... In the circuit shown in Figure 9-1 below, the source voltage, Vs, is “chopped” to produce an average voltage somewhere between 0% and 100% of Vs. Thus the average value of the voltage applied to the Motor, Vm, is controlled by closing and opening the “switch”, Q1. To close the switch, a firing signa ...
Configuration and Selection of Microwave Generators
Configuration and Selection of Microwave Generators

... mode, which achieves a higher peak output powers within a specified time period. Many pulse power supplies also have the capability to operate the magnetron in “CW” or continuous mode as well. ...
Networking Hardware Components
Networking Hardware Components

... structure and the maximum length would be 100 metres. Stranded Cables have no fixed maximum length, but are generally used for short distances. The Cables are flexible, and the maximum length largely depends on Cable Quality and Shielding. ...
2. measurement of the windings resistance for universal motors
2. measurement of the windings resistance for universal motors

... with AC supply, it still produces a unidirectional torque. The armature winding and the field winding are connected in series, so they are in phase. Since the polarity of AC changes periodically, the direction of the magnetic field and the direction of the armature current reverse in such a way that ...
High power factor rectifier with reduced conduction and
High power factor rectifier with reduced conduction and

... flows through two semiconductors simultaneously, instead of three. However, the main difficulty in these converters is that the sensoring of the input voltage and current must be isolated, carrying out additional complexity and cost. This paper proposes a new high power factor rectifier with reduced ...
BASIC TELECOMMUNICATIONS
BASIC TELECOMMUNICATIONS

... The 2 wires are called tip and ring and make up what is referred to as a pair and what is referred as the subscriber loop by the phone company Tip is the ground side (positive) and Ring is the battery (negative) side of a phone circuit. ...
English
English

GNS RF2422
GNS RF2422

... The input of the phase shifting network. This pin has an internal DC-blocking capacitor. At frequencies higher than 2GHz this port is well-matched to 50. This port is voltage driven so matching at lower frequencies is not required. Power supply for all circuits except the RF output stage. An extern ...
MAX9710/MAX9711 3W Mono/Stereo BTL Audio Power Amplifiers with Shutdown General Description
MAX9710/MAX9711 3W Mono/Stereo BTL Audio Power Amplifiers with Shutdown General Description

... PC99/01 compliant, operate from a single 4.5V to 5.5V supply, and feature an industry-leading 100dB PSRR, which allows these devices to operate from noisy supplies without additional, costly power-supply conditioning. An ultra-low 0.005% THD+N ensures clean, low-distortion amplification of the audio ...
RA01L8693MA
RA01L8693MA

... In base stations, frequent on/off switching can cause thermal expansion of the resin that coats the transistor chips and can result in reduced or no output power. The bond wires in the resin will break after long-term thermally induced mechanical stress. Quality: Mitsubishi Electric is not liable fo ...
Aalborg Universitet Function
Aalborg Universitet Function

... find equivalent models between the inverter-based generators and the synchronous machines in order to study their general stability and to improve their operation control [11-13]. Different types of controls, based on the small signal analysis have been proposed on the past to improve the stability ...
ETS80X10.5C - AMETEK Programmable Power
ETS80X10.5C - AMETEK Programmable Power

Maxstar® 150 STH
Maxstar® 150 STH

Campus-Wide IP Television and VoIP
Campus-Wide IP Television and VoIP

... is less than $400 per unit for both the IPTV and VoIP delivery. This enabled PurDigital to submit the winning bid to replace GSU’s cable and telephone providers. ter adapters. They then place one of these shelves in a centralized GSU residence hall closet in order to service an average of 25 living ...
Power Measurement Guide
Power Measurement Guide

... multiplied the current by “-1”, then the waveform is inverted. While the waveform will not exactly match the “pwr” waveform as described in previous sections, they should be fairly close, especially for small values of “gmin”. 9. At this point, you may perform average, peak, or integral functions on ...
< 1 ... 301 302 303 304 305 306 307 308 309 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report