• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Fractional Power Control for Decentralized Wireless Networks
Fractional Power Control for Decentralized Wireless Networks

... quality according to the well-known waterfilling policy [2]. On the other hand, if the objective is to consistently achieve a target rate (or SNR), then the power should be adjusted so that this target level is exactly met. Such an objective is philosophically the opposite of waterfilling, since pow ...
Average Power Balancing Control of a STATCOM based on the
Average Power Balancing Control of a STATCOM based on the

... This paper proposes a new DC link voltages control method for the MMCC-SSBC based STATCOM. This new method utilizes both positive- and negative-sequence voltages and currents in its DC bus balancing control to enhance its operation in the grid fault condition. Such low-voltage ride-through capabilit ...
Schneider Telemechanique Altivar 71 Installation Manual (0.37kW
Schneider Telemechanique Altivar 71 Installation Manual (0.37kW

fire alarm cable
fire alarm cable

... 4. Test wiring for grounds, short circuits, and open faults before the system is placed in operation. 5. Always use the proper gauge of wire to avoid signal loss. 6. Avoid interference when routing wire. 7. Installation shall be made to prevent the spread of fire from floor to floor. 8. A minimum of ...
MULTI-BEAM 2-Wire AC Power Block Modules
MULTI-BEAM 2-Wire AC Power Block Modules

TOP221 - Power Integrations
TOP221 - Power Integrations

... The first time VC reaches the upper threshold, the highvoltage current source is turned off and the PWM modulator and output transistor are activated, as shown in Figure 5(a). During normal operation (when the output voltage is regulated) feedback control current supplies the VC supply current. The ...
Energy Consumption in Wired and Wireless Access Networks
Energy Consumption in Wired and Wireless Access Networks

... support many customers and is highly branched; in such cases we allow one trunk amplifier to support up to eight line amplifiers. Each node requires at least one video and one data port on the BNP that combines the RF signals, and a number of RF data channels from the UBR. When modeling high data lo ...
Evaluates:  MAX15022 MAX15022 Evaluation Kit General Description Features
Evaluates: MAX15022 MAX15022 Evaluation Kit General Description Features

... PWM switching synchronous step-down regulators and two LDO controllers. The EV kit regulator outputs can be configured for sequencing, ratiometric-tracking, or coincident-tracking mode. The MAX15022 IC operates with either step-down regulator outputs as the master; however, the EV kit is designed wi ...
Evaluation of Power Transistors Figure of Merit for Hard
Evaluation of Power Transistors Figure of Merit for Hard

... Figure 2 to Figure 4 are showing results from parametrical experimental analysis of switching performance of transistor (evaluation of transistor’s switching power losses) in dependency on transistor’s current and switching frequency. Each transistor was investigated separately with the use of unive ...
Chap. 2 Basic concepts
Chap. 2 Basic concepts

... to link all the device in the network Nodes are connected to the bus cable by drop lines and taps ...
SA-400-73 Manual - Carson Manufacturing Company, Inc.
SA-400-73 Manual - Carson Manufacturing Company, Inc.

... Do not operate siren without adequate hearing protection for you and anyone in immediate vicinity. (Ref. OSHA 1910.95 for occupational noise exposure guidelines) Mounting - Mount the unit for easy access by the vehicle operator. DO NOT mount in air bag deployment area. Assure clearances before drill ...
Power Demand and Energy Usage of Container Crane
Power Demand and Energy Usage of Container Crane

Power Supply Unit with Charge LED
Power Supply Unit with Charge LED

... Document No. TOEP YEAOPT 06 Read these safety precautions first. These safety precautions are packaged with the G5 HHP Power Supply Unit with Charge LED. It contains important safety information related to this product. ...
unified power flow controller comprehensive
unified power flow controller comprehensive

... applicable. Moreover, since the UPFC parameters are computed after the load flow has converged, there is no way of knowing, during the iterative process, whether or not the UPFC parameters are within limits. Reference [4] takes the approach of modeling the UPFC as a series reactance. The voltage mag ...
Advances in Environmental Biology
Advances in Environmental Biology

... The relationship between power quality and distribution system has been a subject of interest for several years. Recently, with the growth of industry manufacturers and population, electric power quality becomes more and more important. As one of the most common power quality issues, flicker, causin ...
1764-SO001A-US-P, MicroLogix 1500 System Overview
1764-SO001A-US-P, MicroLogix 1500 System Overview



Power Amplifier (Class A) - City University of Hong Kong
Power Amplifier (Class A) - City University of Hong Kong

... Transformer-Coupled Class-A Amplifier • An important characteristic of the transformer is the ability to produce a counter emf, or kick ...
IBP1011L900 - Integra Technologies, Inc.
IBP1011L900 - Integra Technologies, Inc.

... The high power pulsed avionics pallet part number IBP1011L800 is designed for L-Band avionics systems operating at 1030 MHz. While operating in class C mode under Mode S-ELM pulse burst conditions at VCC = 48V, this amplifier supplies a minimum of 900 watts of peak pulse power. It utilizes a low los ...
A Wireless ECG Recording System for Small Animal Models of Heart
A Wireless ECG Recording System for Small Animal Models of Heart

... may be required to fully integrate regenerating myocardium with host myocardium [5]. However, the current ECG recording methodology used with the animals requires pharmacological sedation which affects the cardiac information [6]. Therefore it is highly desirable to have a long-term wearable and wir ...
AD8300 数据手册DataSheet 下载
AD8300 数据手册DataSheet 下载

K1S28161CA
K1S28161CA

... Output Enable to Valid Output ...
Aalborg Universitet Blaabjerg, Frede; Ma, Ke; Yang, Yongheng
Aalborg Universitet Blaabjerg, Frede; Ma, Ke; Yang, Yongheng

... grid voltage sags. Meanwhile, WTSs should also provide reactive power (up to 100% current capacity) for grid voltage recovery during LVRT. Fig. 6 shows an example of the required amount of reactive current under grid faults defined in the German [22] and Danish grid codes [21]. This demand is relati ...
Instruction Manual PWM Driver 5A-LP2 Luci Pte. Ltd.
Instruction Manual PWM Driver 5A-LP2 Luci Pte. Ltd.

Instructions for Use
Instructions for Use

< 1 ... 208 209 210 211 212 213 214 215 216 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report