• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Chapter 1. Introduction to Data Communications
Chapter 1. Introduction to Data Communications

... – MAC-based VLANs assign computers according each computer’s data link layer address – IP-based VLANs assign computers using their IP-address – Application-based VLANs assign computers depending on the application that the computer typically uses. This has the advantage of allowing precise allocatio ...
1 high-speed positioning system installation
1 high-speed positioning system installation

... In area of strong thunderstorm hit or near high sensitive voltage (such as near high-voltage transformer substation), you need to install additional high-power thunder protection device or lightning rod. The thunder protection and earth of the outdoor device and cable shall be considered in the buil ...
5_Data Link Layer
5_Data Link Layer

... used to get datagram from one interface to another physicallyconnected interface (same network) 48 bit MAC address (for most LANs) burned in the adapter ROM, but can be modified. ...
POWER QUALITY
POWER QUALITY

TECHNICAL SPECIFICATION FOR AC/ DC TIG WELDING M
TECHNICAL SPECIFICATION FOR AC/ DC TIG WELDING M

... (10) Continuously adjustable welding power (11) Step-less control of current setting. (12) Inbuilt safety measures against open circuit, short circuit or phase fault etc. (13) Inbuilt protective system to sense the water flow in the torch and prevent burning of torch in case of insufficient / stoppa ...
DM-330 DM-340MVT/MVZ/MW
DM-330 DM-340MVT/MVZ/MW

... Copyright Alinco,Inc., Osaka, Japan. All rights reserved. Although Alinco has designed this brochure to be as accurate and comprehensive as possible, we reserve the right to make changes at any time to our equipment line, optional accessories, specifications, standard accessories, or availability of ...
2 - Considerations on the Operation of SCDC Cables Fed by
2 - Considerations on the Operation of SCDC Cables Fed by

... 2 - Considerations on the Operation of SCDC Cables Fed by Multiple Voltage Source Converters Introduction Voltage sourced converter (VSC) based HVDC transmission has come into use in the last ten years. These systems are based on a modular design, reducing the installation time. Such a system could ...
NI Camera Link I/O Extension Board (PCIe) User Guide
NI Camera Link I/O Extension Board (PCIe) User Guide

... Do not operate the device in a manner not specified in the documentation. Misuse of the device may result in a hazard and may compromise the safety protection built into the device. If the device is damaged, turn it off and do not use it until service-trained personnel can check its safety. If neces ...
evaluating the performance of external fault ride
evaluating the performance of external fault ride

Presentation Slides
Presentation Slides

Part I: Introduction
Part I: Introduction

... • Addresses: 6 bytes, frame is received by all adapters on a LAN and dropped if address does not match • Type: indicates the higher layer protocol, mostly IP but others may be supported such as Novell IPX and AppleTalk) • CRC: checked at receiver, if error is detected, the frame is simply dropped ...
Mini-curso-FACTS-2001F
Mini-curso-FACTS-2001F

... clear sense is needed to perceive them, and to judge rightly and justly when they are perceived, without for the most part being able to demonstrate them in order as in mathematics, because the principles are not known to us in the same way, and because it would be an endless matter to undertake it. ...
Chapter 1 General ARTICLE 100 Definitions
Chapter 1 General ARTICLE 100 Definitions

... Conduit Body. A separate portion of a conduit or tubing system that provides access through a removable cover(s) to the interior of the system at a junction of two or more sections of the system or at a terminal point of the system. Boxes such as FS and FD or larger cast or sheet metal boxes are not ...
The Impact of Power Switching Devices on the Thermal
The Impact of Power Switching Devices on the Thermal

Reference Manual
Reference Manual

... The USB port can deliver enough power for the vast majority of designs. It is possible that a very demanding application, including an application that drives many peripheral boards, might require more power than can be delivered by the USB port. Some applications may also need to run without being ...
Types of Electrical Meters in Data Centers
Types of Electrical Meters in Data Centers

... consumption. Meters at various points throughout the architecture enable this. Sometimes temporary meters are put in place to address this need. See the side-bar for an overview of temporary meters and their role (and limitations) in an energy efficiency plan. Decrease unplanned downtime events – In ...
Marine Amplifier
Marine Amplifier

... all marine amplifiers use heat-tempered PCB’s for maximum product life and performance. Gold plated connectology, ensures your signal flows from the head unit through to the speakers with as little injected distortion and noise as possible. This results is a very clean and very powerful reproduction ...
Rajasthan Technical University, Kota  COURSE - FILE
Rajasthan Technical University, Kota COURSE - FILE

... : Electrical Engineering ...
Power Amplifier - TA Distribution Finland
Power Amplifier - TA Distribution Finland

SpeakerCraft-BB275-M..
SpeakerCraft-BB275-M..

... There are three ways to turn the amplifier on and off. Use the following list to decide which mode will work best for your application. Constant: Use this selection when you wish to manually turn the amplifier on and off by using the front mounted power button. Trigger: Use this selection if you wis ...
Powering Your Ideas. PMBus™ Implementers Forum
Powering Your Ideas. PMBus™ Implementers Forum

... Transmitter: The device which sends data to the bus Receiver: The device which receives data from the bus Master: The device which initiates a transfer, generates clock signals and terminates a transfer Slave: The device addressed by a master Multi-master: More than one master can attempt to control ...
Test Tool for Industrial Ethernet Network Performance
Test Tool for Industrial Ethernet Network Performance

... performance metrics, tests, and tools. NIST can take a wide view at the issue of the industrial Ethernet performance and focus on what will provide the most meaningful metrics for both the vendors and the end-users. NIST has no direct affiliation with any particular group or technology which is why ...
RF5626 Proposed
RF5626 Proposed

... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
2014 B1 Special Report - SC B1
2014 B1 Special Report - SC B1

... B1-101: The paper describes the use of T-joints at both 132 kV and 220 kV in confined spaces when a new line is to be added in a substation. T-joints will require less space but also there is a possibility to provide switching capability between underground cables and overhead lines. Another possibi ...
ECEN5817L28
ECEN5817L28

... Summary of key points 8. In the quasi-square-wave zero-voltage-switching resonant switches, all semiconductor devices operate with zero-voltage switching, and with peak voltages equal to those of the parent PWM converter. The switch conversion ratio is restricted to the range 0.5 ≤ µ ≤ 1. 9. The sm ...
< 1 ... 196 197 198 199 200 201 202 203 204 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report