• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... design. In particular, in deep sub-micrometer technology (65 nm and below) high power dissipation become a major concern. For many individual processor units, several power reduction techniques have been proposed in the literature. Attempts have been made to either design new power-efficient units o ...
IEEE SM 01 Paper
IEEE SM 01 Paper

... 3.Independent Operation Mode of the two VSCs Should maintenance be required on one side of the BTB, the other side can still provide voltage control to either side of the BTB. This is done by opening the DC bus to split it into two halves. As the DC link is open, no active power can be transferred b ...
power factor correction filters with static switching fre series
power factor correction filters with static switching fre series

... low and perturbations generated by other conventional equipment and which may disturb electronic and computer equipment are completely avoided. FRE equipment is controlled by a fast power factor controller COMPUTER (*) which is able to perform up to 14 operations/sec if such a fast response is requi ...
Electronic Components for Green Power Generation
Electronic Components for Green Power Generation

... generation. Alternatively, the PCC® (power capacitor chip) can also be designed into such applications. This compact power capacitor features extremely low ESR and ESL values and can be mounted directly onto the IGBT module. Transformers and power inductors also play a key role in inverters. Our cap ...
PDF
PDF

... to the rising cost of traditional energy sources and the environmentalfriendly features of renewable energy. The types of renewable energy include solar, wind, hydrogen, biomass, geothermal, hydropower, and biodiesel. The photovoltaic-based generation has gained importance in DG systems due to its c ...
SLK2721 数据资料 dataSheet 下载
SLK2721 数据资料 dataSheet 下载

74-3468-3 - XM500 TCP/IP Modem
74-3468-3 - XM500 TCP/IP Modem

... The XM500 allows for communication between standard EXCEL 5000 controllers and the Excel Building Supervisor Central, or any controller on the Light Commercial Building System (LCBS) and LONSTATION™, via standard EthernetTCP/IP based LAN/WAN networks. The XM500 is easy to install and to configure. T ...
POWER QUALITY DISTURBANCE ON PERFORMANCE OF
POWER QUALITY DISTURBANCE ON PERFORMANCE OF

packaging
packaging

HPE Power Advisor: A tool for estimating power requirements for
HPE Power Advisor: A tool for estimating power requirements for

... Configuring a system of single-node servers ........................................................................................................................................................................................................................................................ 12 Conf ...
Aalborg Universitet
Aalborg Universitet

... impedance in the apparatus to vary from 150 Ω, but we assume that the internal impedance, Zs, is fixed to 150 Ω, and so measuring with ZL = 150 Ω results in the best matching cf. (2) and, consequently, the upper bound of power transfer. But what if the source and load impedances are both other than ...
Low power analog or RF amplifier
Low power analog or RF amplifier

... Power Consumption Traditional CMOS LNA P = Idd x Vdd = 3.668mA x 2V = 7.23 mW ...
DRV8837,DRV8838 - Texas Instruments
DRV8837,DRV8838 - Texas Instruments

... The DRV883x family of devices is an H-bridge driver that can drive one dc motor or other devices like solenoids. The outputs are controlled using either a PWM interface (IN1 and IN2) on the DRV8837 device or a PH-EN interface on the DRV8838 device. A low-power sleep mode is included, which can be en ...
Project code STCU/5388. Development, realisation and testing of the sample... phase shift transformer with thyristor control. Period of realisation 2011-2012....
Project code STCU/5388. Development, realisation and testing of the sample... phase shift transformer with thyristor control. Period of realisation 2011-2012....

Aalborg Universitet Station
Aalborg Universitet Station

... not influence the overall charging period, but fast current transients have an adverse impact on battery lifetime. 2) Grid interface; AC/DC rectifier, the dynamics of which are determined by the design of grid filter and inner control loops. To that end, the output filter my be a single three-phase ...
packaging
packaging

NOTICE TO INSTALLER:  Instructions must remain with installation. SECTION: 6.10.100
NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: 6.10.100

CISSOID Product Selector Guide.
CISSOID Product Selector Guide.

... VOLCANO family includes a range of turnkey DC-DC converter designs that can be used for immediate evaluation and possible adaptation of the electrical features. It is a quick path for the design of hightemperature switched-mode power supplies and seamless integration on a PCB or in a Multi-Chip ...
Control of DPGS Under Grid Faults
Control of DPGS Under Grid Faults

... Reactive power grid support is an ancillary service that will be paid by TSO in the future making it more attractive ...
Chapter 8 Electrical Power 8.1 Introduction
Chapter 8 Electrical Power 8.1 Introduction

... protection using separate and independent current and control circuits. Normal and alternate preferred power conductors located between the Fermi 3 UATs and RATs and the 345 kV switchyard buses are protected by dual high-speed current differential schemes. The 345 kV switchyard circuit breakers are ...
H3AM-NSR-B AC100-240 Datasheet
H3AM-NSR-B AC100-240 Datasheet

... Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originall ...
UPnP & DLNA
UPnP & DLNA

Stability Analysis of Single Machine Infinite Bus Power System
Stability Analysis of Single Machine Infinite Bus Power System

IID-695 Gen Interconnect Request 2010 Updated:2012-07-13 15:59 CS
IID-695 Gen Interconnect Request 2010 Updated:2012-07-13 15:59 CS

... and Power System Stabilizer Models List for synchronous generators. Each generator requesting interconnection to the IID System should select the name of each of the appropriate dynamic model that would represent the elements of the generation equipment for your project. Once you select the model’s ...
Dynamic Current Mode Inverter for Ultra-Low Power Near
Dynamic Current Mode Inverter for Ultra-Low Power Near

... CMOS based logic suffers from inherent limitations at low supply voltages, which include performance degradation, reduced noise margin, and lower output voltage swing. One potential solution to mitigate the problems present with CMOS at near-threshold voltages is the use of differential logic circui ...
< 1 ... 183 184 185 186 187 188 189 190 191 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report