D. J. Perreault and V. Caliskan, “A New Design for Automotive Alternators,” SAE Paper 2000-01-C084, 2000 International Congress on Transportation Electronics (Convergence 2000) , Detroit, MI, Oct. 2000, pp. 583-594.
... As described above, an alternator with the power vs. voltage curves of Fig. 5 is well suited to an output voltage of 14 V, but is not suitable for a higher voltage such as 42 V. If one wanted to operate at 42 V, one could rewind the stator with three times as many turns of wire having a third the cr ...
... As described above, an alternator with the power vs. voltage curves of Fig. 5 is well suited to an output voltage of 14 V, but is not suitable for a higher voltage such as 42 V. If one wanted to operate at 42 V, one could rewind the stator with three times as many turns of wire having a third the cr ...
SMJE 2103 Electiral Power System
... (a) If the power system is exactly as described above in Figure (a), what will the voltage at the load be? What will the transmission line losses be? (b) Suppose a 1:10 step-up transformer is placed at the generator end of the transmission line and a 10:1 step-down transformer is placed at the load ...
... (a) If the power system is exactly as described above in Figure (a), what will the voltage at the load be? What will the transmission line losses be? (b) Suppose a 1:10 step-up transformer is placed at the generator end of the transmission line and a 10:1 step-down transformer is placed at the load ...
Application Note TLE8110EE
... Unipolar or bipolar drive - see Figure 1: Bipolar drive requires two H-bridges for driving, but uses the full amount of copper windings, so the motor delivers more torque. Unipolar drive only uses half of the winding, but only requires four low-side switches. ...
... Unipolar or bipolar drive - see Figure 1: Bipolar drive requires two H-bridges for driving, but uses the full amount of copper windings, so the motor delivers more torque. Unipolar drive only uses half of the winding, but only requires four low-side switches. ...
步进电机的物理原理
... Stepping motors can be viewed as electric motors without commutators. Typically, all windings in the motor are part of the stator, and the rotor is either a permanent magnet or, in the case of variable reluctance motors, a toothed block of some magnetically soft material. All of the commutation must ...
... Stepping motors can be viewed as electric motors without commutators. Typically, all windings in the motor are part of the stator, and the rotor is either a permanent magnet or, in the case of variable reluctance motors, a toothed block of some magnetically soft material. All of the commutation must ...
HF2614291439
... power system to develop restoring forces equal to or greater than the disturbing forces to maintain the state of equilibrium. Since power systems rely on synchronous machines for generation of electrical power, a necessary condition for satisfactory system operation is that all synchronous machines ...
... power system to develop restoring forces equal to or greater than the disturbing forces to maintain the state of equilibrium. Since power systems rely on synchronous machines for generation of electrical power, a necessary condition for satisfactory system operation is that all synchronous machines ...
AXICOM Latching Relays
... They have features like mechanical locks or gears inside keeping the contacts in the switching position. Mechanical latching relays are not very common in recent telecom and signal relay designs and can be disregarded ...
... They have features like mechanical locks or gears inside keeping the contacts in the switching position. Mechanical latching relays are not very common in recent telecom and signal relay designs and can be disregarded ...
Nineteenth-Century Developments in Coiled Instruments and
... disturbance in a coiled wire loop that was not connected to any battery at all. It came about in that loop only at the moment of closing or breaking the connection between a trough (multi-cell) battery and an entirely separate wire coil. The disturbance was evident by the deflection of a magnetic ne ...
... disturbance in a coiled wire loop that was not connected to any battery at all. It came about in that loop only at the moment of closing or breaking the connection between a trough (multi-cell) battery and an entirely separate wire coil. The disturbance was evident by the deflection of a magnetic ne ...
GENERATOR PROTECTION
... Directional Neutral Overcurrent: 87G Low-Z Grounded Generator 87GD element provides selectivity on multiple bused machine applications Requires phase CTs, or terminal side zero-sequence CT, and a ground CT 87GD uses currents with directionalization for security and selectivity 87GD is set fa ...
... Directional Neutral Overcurrent: 87G Low-Z Grounded Generator 87GD element provides selectivity on multiple bused machine applications Requires phase CTs, or terminal side zero-sequence CT, and a ground CT 87GD uses currents with directionalization for security and selectivity 87GD is set fa ...