• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Tender text
Tender text

... Luminous flux depending on connected lamp power Module is suitable for maintained or non-maintained mode. Maintained mode with additional conventional ballast or electronic ballast. Maximum distance VL8 – EVG: 1m. The switchover between mains and battery operation is carried out via a 5-pole switcho ...
Electrophoresis Safety
Electrophoresis Safety

... unintentional grounding points and conductors (e.g., sinks and other water sources, metal plates, aluminum foil, jewelry, pipes, or other metal equipment). If a darkened box is needed for light sensitive work, a black photographer’s cloth will work as long as it does not come in contact with the buf ...
source - glast lat
source - glast lat

... evaluates the IV curve derivate and registers the change of slope point. If the change of slope point is <175 V the operator marks the envelope with the nonconforming sign, documents the nonconformance in the database, stores the ladder in a separate shipping container from accepted ladders. 4.2.4 D ...
P0305: Procedure For Gyroscope High Voltage To Ground Plane
P0305: Procedure For Gyroscope High Voltage To Ground Plane

... Keithly Model 617 Electrometer, calibrated to manufacturer’s specifications. ...
Insulation Testing of Transformer
Insulation Testing of Transformer

Safety Induction to the Lift & Escalator Industry
Safety Induction to the Lift & Escalator Industry

...  Are you authorised to make changes to electrical circuits and software? All changes must be recorded on the wiring diagrams. Safe use of shorting wires/ jumpers  The primary function of a shorting wire is to bypass a faulty component when fault finding and should only be used when there is no alt ...
Electrical Safety Training
Electrical Safety Training

... circuits may become energized + Broken wire or plug on extension cord + Some of the most frequently violated OSHA standards ...
Principle of Troubleshooting
Principle of Troubleshooting

... - Touch the other lead of your meter to the collector. If you get a reading, the transistor is NPN. - To verify, move the lead from the collector to the emitter and you should still get a reading. If your meter reads open-circuit, then connect the negative lead to the base and touch the positive lea ...
Variable Frequency Drive (VFD) - Energy Management Corporation
Variable Frequency Drive (VFD) - Energy Management Corporation

... As an option, an infrared heat scan can be done on the VFD’s and/or associated power equipment. The ThermaCAM report will include an infrared image of the VFD and/or associated equipment along with digital hot-spot temperature, color image showing temperature profile within the cabinet, and a proble ...
17NDT
17NDT

... Non-destructive test is required to enable the soundness of ship welds to be assessed. 1) Visual examination It is routine procedure. Any surface defects are noticed by the experienced and responsible personnel e.g. incorrect bead shape, high spatter, undercutting, bad stop and start points, incorre ...
2 - TAFE SA
2 - TAFE SA

... b) Hazards associated with low-voltage, extra-low voltage and high-currents encompassing:  Parts of an electronic systems and equipment that operate at low-voltage and extralow voltage,  Parts of an electronic systems and equipment where high-currents are likely. c) Risks and control measures asso ...
Classroom and Lab Policies
Classroom and Lab Policies

... You are expected to be present at every class meeting with the exception of certain weather conditions. Note: Follow instructions for ECC weather related class late schedules or closings. It is the responsibility of the student to inform the instructor of an absence and to find out what was done in ...
instruction manual megometers model mg-25a, 50a
instruction manual megometers model mg-25a, 50a

... earth through a ground connection of sufficiently low impedance and having sufficient ampacity that ground-fault current which may occur cannot build-up to voltages dangerous to personnel". The test set is provided with an input line cord equipped with a three-prong, grounding-type plug. The test se ...
17th Edition (BS 7671:2008) incorporating Amendment No 1
17th Edition (BS 7671:2008) incorporating Amendment No 1

... voltage drops across the conductors. Section 534 contains a number of requirements for the Connection of SPDs depending on the type of supply and system earthing. Therefore, for example, Section 534 requires that SPDs at or near the origin of the installation (if there is a direct connection between ...
108-2399 Product Specification CFP 100 Gigabit Pluggable Host Connector and
108-2399 Product Specification CFP 100 Gigabit Pluggable Host Connector and

... Gigabit Pluggable Host Connector and Transceiver Plug Connector System. ...
International Harvester Scout Dashboard Wiring Harness Test Fixture
International Harvester Scout Dashboard Wiring Harness Test Fixture

... a manual test of the circuits having switches in the circuit. These circuits cannot be tested automatically. ...
SOT-723 Plastic-Encapsulate Diodes 5V0AT7 CESDLC
SOT-723 Plastic-Encapsulate Diodes 5V0AT7 CESDLC

... ELECTRICAL CHARACTERISTICS (Ta= 25°C unless otherwise noted, VF = 0.9 V Max. @ IF = 10mA for all types) ...
Power Quality Counts
Power Quality Counts

Test Philosophy
Test Philosophy

... • In-circuit testing of tri-state ICs • Disables IC • Measures impedance of output pins (high impedance expected) • Displays CFLT on driven pins if not ...
TBS-TPSFE_test
TBS-TPSFE_test

... and B. The status signal was bad generated: R417 had wrong value; after reworking the board was OK. • 95011 did not pass the first functional test: LRS1 over current protection did not work. R507 had a wrong value; after reworking the board was OK. • 95023 did not pass the first functional test: Act ...
RTCA DO-160F Lightning Testing
RTCA DO-160F Lightning Testing

... a) For an individual conductor, core wire current need not exceed the corresponding pin test short-circuit current – straight forward reasoning. b) For multi-stroke and multi-burst, random is achieved through timing – “random” is always a point of discussion. c) If IT cannot be reached – cable too l ...
Safety Short Electric Shock Drowning
Safety Short Electric Shock Drowning

... Know the risk and the simple steps that you can take to prevent it Boating and swimming are great things to do especially when the temperature heats up. However, there may be a hidden danger of which many people are unaware. Be it at a rivers and lakes or at the pool, electric shock drowning (ESD) i ...
Power Quality Counts
Power Quality Counts

108-1965 Product Specification High Speed Serial Data 2 Connector
108-1965 Product Specification High Speed Serial Data 2 Connector

... otherwise specified, the latest edition of the document applies. In the event of conflict between the requirements of this specification and the product drawing, the product drawing shall take precedence. In the event of conflict between the requirements of this specification and the referenced docu ...
Leakage Reactance Interface
Leakage Reactance Interface

... event, can lead to immediate failure. Although a transformer can remain in service with partially deformed windings, its reliability is reduced. Winding distortion is not readily picked up by other AC field tests and should therefore be included during maintenance testing. The test is also recommend ...
< 1 ... 144 145 146 147 148 149 150 151 152 ... 171 >

Portable appliance testing



Portable appliance testing (commonly known as ""PAT"", ""PAT Inspection"" or ""PAT Testing"") is the name of a process in the United Kingdom, the Republic of Ireland, New Zealand and Australia by which electrical appliances are routinely checked for safety. The correct term for the whole process is ""in-service inspection & testing of electrical equipment"".Similar procedures exist in other countries, for example, testing of equipment according to DGUV Vorschrift 3 in Germany.Health and safety regulations require that electrical appliances are safe and maintained to prevent harm to workers. Many equipment manufacturers recommend testing at regular intervals to ensure continual safety; the interval between tests depending on both the type of appliance and the environment in which it is to be used. The European Low Voltage Directive governs the manufacture or importation of electrical appliances. Compliance to this has to be declared and indicated by the display of the CE mark on the product. The responsibility for this lies with the manufacturer or the importer and is policed by Trading Standards.Testing equipment has been specifically developed for PAT inspections, based on the testing equipment used by manufacturers to ensure compliance with the British Standard Code of Practice and European product standards relevant to that type of appliance. This in turn allows testing and the interpretation of results to be de-skilled to a large extent. The inspection of the appliances can largely be carried out in-house in many organisations. This can result in cost savings and more flexibility as to exactly when a PAT is carried out.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report