• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
emp generation mechanism and its destructive
emp generation mechanism and its destructive

... emission cathode because such cathodes “ turn on “ at relatively low electric fields and deliver the very high current densities (100 A / cm 2), hence generates extremely high power. Carbon fiber cathodes impregnated with Cesium iodide (Cs I) have proven to be better choice. Klystrons, Magnetrons, S ...
Most Common Errors in Service Entrance and Load Side Install
Most Common Errors in Service Entrance and Load Side Install

... 1. It is also susceptible to ferroresonance *, especially during 1ø sequential switching when energized in series with cable capacitance to ground. 2. The bank cannot be parallel with D-D or Y-Y banks because of the phase difference of 30 degrees between line voltages of the banks on the secondary s ...
Basic Circuit Elements - New Age International
Basic Circuit Elements - New Age International

... possible due to the fact that an Electrical Engineer is able to assess, analyse and predict with greater accuracy the performance of various systems with the help of a simple but powerful tool known as circuit theory. In fact circuit theory has revolutionised the process of analysis in all branches ...
Studying the Electric Field Near a Plasma Globe
Studying the Electric Field Near a Plasma Globe

... Since your body is a conductor and can affect the electric field strength, it is best for quantitative results if you don’t directly hold onto the antenna. An alternative is to tape the end of the antenna (the end of the wire not plugged into the meter) to one end of a wooden dowel or stick that is ...
Type here the title of your Paper
Type here the title of your Paper

ID Innovations - Purdue Engineering
ID Innovations - Purdue Engineering

closed form modeling of crosstalk for distributed rlcg on-chip
closed form modeling of crosstalk for distributed rlcg on-chip

... challenges is referred as signal integrity in general. Among all these problems, capacitive coupling induced cross talk is the issue that has been seen by an increasing number of backend vendors [14]. Cross talk typically happens between two adjacent wires when their cross coupling capacitance is su ...
Lighting Load Protection
Lighting Load Protection

Transformer Voltage Regulation and Efficiency
Transformer Voltage Regulation and Efficiency

... in field to accommodate variations in tap voltages • While this tap can not be changed when power is applied to transformer • Some times voltage varies widely with load, i.e. when high line impedance exist between generators & particular load; while normal loads should be supplied by an essentially ...
ENERGY CONVERSION ONE
ENERGY CONVERSION ONE

... in field to accommodate variations in tap voltages • While this tap can not be changed when power is applied to transformer • Some times voltage varies widely with load, i.e. when high line impedance exist between generators & particular load; while normal loads should be supplied by an essentially ...
PDF
PDF

... transformer. An EMI filter and a diode bridge rectifier is also included in this converter topology, EMI filter is used to eliminate high frequency current harmonics at the input line. Diode bridge rectifier is used to convert AC source voltage to DC voltage. The control of this single switch is don ...
Chapter 2
Chapter 2

Faraday`s Law and Joule Heating
Faraday`s Law and Joule Heating

1.Integrating Coupled Inductor and Switched - ISSN:2454-356X
1.Integrating Coupled Inductor and Switched - ISSN:2454-356X

... analyses are discussed thoroughly. Therefore, a main power switch with low resistance RDS(ON) can be used to reduce the conduction losses. The operation principle and the steady-state analyses are discussed thoroughly. Some transformer-based converters like forward, push–pull, or fly back converters ...
Secondary Wiring Methods
Secondary Wiring Methods

Lecture 13
Lecture 13

ZVS Phase Shift Full Bridge
ZVS Phase Shift Full Bridge

Power Electronics Solution to Dust Emissions from
Power Electronics Solution to Dust Emissions from

... The short circuit reactance of single phase transformers rated several tenths of kVА is relatively small and insufficient for the proper limitation of the short circuit current. Eventual design of dedicated transformer with increased leakage flux would increase the losses as well as the size and wei ...
Chapter 4: DC Meters - Part 1
Chapter 4: DC Meters - Part 1

2014 Influence of Discrete Inductance Curves on The Simulation of a Round Rotor Generator Using Coupled Circuit Method
2014 Influence of Discrete Inductance Curves on The Simulation of a Round Rotor Generator Using Coupled Circuit Method

Ground Fault Protection on neon secondaries
Ground Fault Protection on neon secondaries

Evaluation of Magnetic Materials for Very High Frequency Power
Evaluation of Magnetic Materials for Very High Frequency Power

Pi Speaker Alignment Theory
Pi Speaker Alignment Theory

Trajectory Sensitivities to Assess Influence of Components and
Trajectory Sensitivities to Assess Influence of Components and

... with the bus number on the x-axis with the corresponding sensitivity on the y-axis. Size and sign of the bars indicates how much bus-voltages would change for small positive changes in the turns ratio. The right most positive portion of the bar graph in Figure 4 can be interpreted as impacts on the ...
Static characteristics of a new doubly salient permanent magnet motor
Static characteristics of a new doubly salient permanent magnet motor

... of cross-coupling between the PM flux and armature flux on inductances is firstly taken into account. The results indicate that the effect of the cross-coupling and the mutual inductance in the DSPM motor are significant and nonnegligible. Both the inductance-flux method and the flux-current diagram ...
< 1 ... 39 40 41 42 43 44 45 46 47 ... 173 >

Resonant inductive coupling



Resonant inductive coupling or electrodynamic induction is the near field wireless transmission of electrical energy between two magnetically coupled coils that are part of resonant circuits tuned to resonate at the same frequency. This process occurs in a resonant transformer, an electrical component which consists of two high Q coils wound on the same core with capacitors connected across the windings to make two coupled LC circuits. Resonant transformers are widely used in radio circuits as bandpass filters, and in switching power supplies. Resonant inductive coupling is also being used in wireless power systems. Here the two LC circuits are in different devices; a transmitter coil in one device transmits electric power across an intervening space to a resonant receiver coil in another device. This technology is being developed for powering and charging portable devices such as cellphones and tablet computers at a distance, without being tethered to an outlet.Resonant transfer works by making a coil ring with an oscillating current. This generates an oscillating magnetic field. Because the coil is highly resonant, any energy placed in the coil dies away relatively slowly over very many cycles; but if a second coil is brought near it, the coil can pick up most of the energy before it is lost, even if it is some distance away. The fields used are predominately non-radiative, near fields (sometimes called evanescent waves), as all hardware is kept well within the 1/4 wavelength distance they radiate little energy from the transmitter to infinity.One of the applications of the resonant transformer is for the CCFL inverter. Another application of the resonant transformer is to couple between stages of a superheterodyne receiver, where the selectivity of the receiver is provided by tuned transformers in the intermediate-frequency amplifiers. The Tesla coil is a resonant transformer circuit used to generate very high voltages, and is able to provide much higher current than high voltage electrostatic machines such as the Van de Graaff generator. Resonant energy transfer is the operating principle behind proposed short range (up to 2 metre) wireless electricity systems such as WiTricity or Rezence and systems that have already been deployed, such as Qi power transfer, passive RFID tags and contactless smart cards.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report