• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
User's Model 700924
User's Model 700924

... This probe must be grounded with the BNC shell and an auxiliary grounding terminal, through the grounding conductor of the power cord of the measuring instrument or other appropriate grounding conductor. Before making connections to the input terminals of the product, ensure that the output connecto ...
DMS-PS4-CM-C Datasheet
DMS-PS4-CM-C Datasheet

... possible energy consumption, be sure to determine your application’s total current requirements. This is especially true when using DMS-PS-CM supplies to power DATEL’s energy-efficient LED and/or LCD display digital panel meters (DPMs) and process monitors. In general, choose a power supply that will ...
3 Phase Power
3 Phase Power

... Because we are considering a balanced system, the power per phase (Q) is identical and the total reactive power (QT) is simply QT = 3 Q. ...
GD3310901094
GD3310901094

... the bus voltage magnitudes, Xij is the reactance of the transmission line & Өij is the phase angle between i and j buses. The power flow through the transmission line can be controlled by changing any one of the above mentioned parameters using different types of FACTS devices. In this paper two typ ...
Programmable AC Current Transducer
Programmable AC Current Transducer

... (after installation USB connection is not possible any more). Additional USB 2.0 interface can only be used for a fast setup without need for auxiliary power supply. This interface is NOT galvanically isolated from analogue output and can be used ONLY unconnected to aux. supply and measuring ...
AN1336
AN1336

... Inadvertent or unexpected loss of power can cause a number of system level problems. Memory loss, uncontrolled program status and indeterminate processor state are just a few of the issues which can occur during catastrophic power failure. Power-fail recovery is critical for applications created to ...
80-6420-10/Rev. A/12-98 - GE Healthcare Life Sciences
80-6420-10/Rev. A/12-98 - GE Healthcare Life Sciences

... circuit detection, no-load detection ...
About measuring power
About measuring power

... Though without being truly self-running, you know with all the 'crest', harmonics and power factor stuff that will come into play to skew any reports of overunity.... But it would still be an interesting test, especially if the numbers were much higher (such as 3-10 times OR MORE) on the output. I w ...
Network design documents
Network design documents

... Allow 48 cm for the panel to swing out from the wall A distribution rack, then it must have a minimum 15.2 cm of wall clearance for the equipment, plus another 30.5-45.5 cm for physical access by workmen and repairmen ...
Lecture 2 - Auburn University
Lecture 2 - Auburn University

...  Binning: Tested DUTs are grouped as ■ Passing the entire test ■ Failing any of the tests ■ Failing because of dc test ■ Failing because of RF Test ■ Failing speed (maximum clock frequency) test  Multisite testing: Testing of several DUTs is parallelized to reduce the test cost.  Test time for a ...
Distribution of electrical energy
Distribution of electrical energy

... High performance 0.2S and 0.5S electronic multifunction energy meter CIRWATT 502B (0.2S type in active energy) and CIRWATT 405B (0.5S type in active energy) are the new range of electronic energy multifunction meters which offer highest performance for electrical energy substations. These meters inc ...
Household DC networks: State of the art and future
Household DC networks: State of the art and future

... recommended standards and configurations have been discussed in previous studies. This work reviews some of the most promising suggestions and further analyses those that are most suitable to be implemented. In addition, a comparative study is carried out between a hybrid AC-DC system and a proposed ...
AND9013 CAT3661 LED Driver Evaluation Board APPLICATION NOTE
AND9013 CAT3661 LED Driver Evaluation Board APPLICATION NOTE

... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor doe ...
PC-6011SD - Test and Measurement Instruments CC
PC-6011SD - Test and Measurement Instruments CC

... SD memory card , sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information ( year, month, data, hour, minute, second ) to the Excel directly, then user can make the further data analysis by themselves. ...
Hybrid Reactive Power Compensators
Hybrid Reactive Power Compensators

... power system parameters must be carefully reviewed to – Optimize the design of the hybrid reactive power compensator – Identify any potential resonance conditions that may be caused by WTG power factor correction capacitors or collector substation capacitors applied in the hybrid compensator ...
Item Spec`s Spec`s with Sw DL 3155M12 DIODE APPLICATIONS
Item Spec`s Spec`s with Sw DL 3155M12 DIODE APPLICATIONS

... DIODE APPLICATIONS MODULE - didactic equipment - circuits blocks: clipping circuit, clamping circuit, one half-wave voltage doubler, simple and double half-wave rectifier, diode bridge rectifier (Graetz bridge) with capacitive input filter, dual power supply, stabilized power supply theoretical topi ...
UPS product brochure
UPS product brochure

... 400 W for use as a UL compliant device. 20 A for use as a UL compliant device. 16.7 A for use as a UL compliant device. An estimated value for standard mounting. Not a guaranteed value. ...
Bourns® Chip Resistors
Bourns® Chip Resistors

... Maximum Working Voltage Maximum Overload Voltage Insulation Resistance Resistance Range ...
May 2004 Single Device Tracks and Monitors Five Supplies
May 2004 Single Device Tracks and Monitors Five Supplies

... the source voltages so that the load voltages cannot begin to ramp before all the supply sources have reached operational levels. All five supplies must concurrently exceed their monitor threshold voltages before ramp-up begins. A user-adjustable timer holds off the start of load ramping, and all su ...
goettlicher_peter_20110509
goettlicher_peter_20110509

... Input filter under investigation See next slide: 10W, C1=220µF ? Peter Göttlicher | LC power workshop | Orsay, May 9th 2011 | Page 14 ...
Shake to Charge Flashlight
Shake to Charge Flashlight

... shaking device, such as this flashlight, is poor. To measure how much power I could get from the shaking magnet generator, I first completed the flashlight dissection process by disconnecting the coil from the flashlight circuit. I then connected the coil to a Schottky diode bridge, made from four 1 ...
Power-monitoring units Power Meter Series 700
Power-monitoring units Power Meter Series 700

... With its large display, you can monitor all three phases and neutral at the same time. The anti-glare display features large 11 mm high characters and powerful backlighting for easy reading even in extreme lighting conditions and viewing angles. The Power Meter Series 700 is available in four versio ...
Timing Kit for 10G-PCIE3-8D Network Adapters
Timing Kit for 10G-PCIE3-8D Network Adapters

... The APIs for Myricom’s DBL™ and Sniffer10G software packages provide timestamps in the metadata associated with each packet. The Linux Ethernet driver provides timestamps via the Linux SO_TIMESTAMPING socket option. The Windows driver does not supply timestamps as there is no Microsoft API for that. ...
Power conversion in line powered equipment
Power conversion in line powered equipment

... only a single poorly regulated output from the transformer. The third is a single flyback switching regulator. This also provides good efficiency, but is even more complex. The example above has no compelling reason to use a flyback regulator. A more appropriate set of requirements for this type of ...
Why select the new Phaseo ABL4
Why select the new Phaseo ABL4

... (1) Standard IEC/EN 61000-3-2 defines the harmonic limits of the input current that can be produced by equipment such as regulated switch mode power supplies ABL4 or ABL8. This standard is only applicable to electrical or electronic devices that are intended for connection to low voltage public dist ...
< 1 ... 138 139 140 141 142 143 144 145 146 ... 221 >

AC adapter



An AC adapter, AC/DC adapter, or AC/DC converter is a type of external power supply, often enclosed in a case similar to an AC plug. Other common names include plug pack, plug-in adapter, adapter block, domestic mains adapter, line power adapter, wall wart, power brick, and power adapter. Adapters for battery-powered equipment may be described as chargers or rechargers (see also battery charger).AC adapters are used with electrical devices that require power but do not contain internal components to derive the required voltage and power from mains power. The internal circuitry of an external power supply is very similar to the design that would be used for a built-in or internal supply.External power supplies are used both with equipment with no other source of power and with battery-powered equipment, where the supply, when plugged in, can sometimes charge the battery in addition to powering the equipment.Use of an external power supply allows portability of equipment powered either by mains or battery without the added bulk of internal power components, and makes it unnecessary to produce equipment for use only with a specified power source; the same device can be powered from 120VAC or 230VAC mains, vehicle or aircraft battery by using a different adapter.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report