Velleman Oscilloscope by Mr. David Fritz
... levels with the sliders or type the values into the boxes. In this case, the generator output is set for a 500Hz, 5Vpp sine wave with a 0.98V DC offset into a high Z load. ...
... levels with the sliders or type the values into the boxes. In this case, the generator output is set for a 500Hz, 5Vpp sine wave with a 0.98V DC offset into a high Z load. ...
Automotive Electronics Product Information Lambda Probe Interface
... b) Failure identification at UN must be enabled with ENSCUN c) Open load is not recognizable; bits used for low battery d) After RD_DIAG or if no failure is present; Failure bits will be restored if failure is still present ...
... b) Failure identification at UN must be enabled with ENSCUN c) Open load is not recognizable; bits used for low battery d) After RD_DIAG or if no failure is present; Failure bits will be restored if failure is still present ...
Figure 1.4
... cell in the computer’s main memory The names for cells in a computer are consecutive numbers, usually starting at zero Cells have an order: “previous cell” and “next cell” have reasonable meanings ...
... cell in the computer’s main memory The names for cells in a computer are consecutive numbers, usually starting at zero Cells have an order: “previous cell” and “next cell” have reasonable meanings ...
Latency Insertion Method for the Analysis of Steady State On
... Process scaling has led to a significant growth in the number of devices on a chip. Consequently, the length and density of interconnects has increased dramatically. As a result, present day circuit designers are facing the problem of analysis of networks with millions of nodes. Traditional matrix-v ...
... Process scaling has led to a significant growth in the number of devices on a chip. Consequently, the length and density of interconnects has increased dramatically. As a result, present day circuit designers are facing the problem of analysis of networks with millions of nodes. Traditional matrix-v ...
Memory
... – i.e. a 2GB and 4GB DIMM are installed 2GB from each module act as dual mode and remaining 2 GB of the 4 GB Module act as single mode ...
... – i.e. a 2GB and 4GB DIMM are installed 2GB from each module act as dual mode and remaining 2 GB of the 4 GB Module act as single mode ...
reotron mew 700
... REOTRON MEW series, single-phase, microprocessor-based, thyristor-controllers are suitable for resistive or resistive/inductive loads, especially those with a high Rcold / Rwarm coefficient. Status relays indicate unit ready and fault conditions. Depending on settings, the controller normally operat ...
... REOTRON MEW series, single-phase, microprocessor-based, thyristor-controllers are suitable for resistive or resistive/inductive loads, especially those with a high Rcold / Rwarm coefficient. Status relays indicate unit ready and fault conditions. Depending on settings, the controller normally operat ...
23400E CheckMate 100
... transmitter or the use the CheckMate 100 to simultaneously power & measure your 2-wire transmitters. Toggle the display to show milliamps or percent of 4 to 20. Source milliamps Calibrate recorders, digital indicators, stroke valves or any other intruments that get their input from a 4 to 20 mA loop ...
... transmitter or the use the CheckMate 100 to simultaneously power & measure your 2-wire transmitters. Toggle the display to show milliamps or percent of 4 to 20. Source milliamps Calibrate recorders, digital indicators, stroke valves or any other intruments that get their input from a 4 to 20 mA loop ...
Slide 1
... receiving radio frequencies can be quite time consuming • An automatic FM radio frequency scanner that finds unused stations will be developed ...
... receiving radio frequencies can be quite time consuming • An automatic FM radio frequency scanner that finds unused stations will be developed ...
Results
... In the first part of this lab, the objective was to study the response of the voltage across a capacitor in an RLC circuit as a function of input. It was shown that the response consisted of a transient and steady state part. The type of transient response was dependent on the resistor used. It was ...
... In the first part of this lab, the objective was to study the response of the voltage across a capacitor in an RLC circuit as a function of input. It was shown that the response consisted of a transient and steady state part. The type of transient response was dependent on the resistor used. It was ...
ADM488 数据手册DataSheet 下载
... The ADM488/ADM489 are ruggedized RS-485 transceivers that operate from a single 5 V supply. They contain protection against radiated and conducted interference and are ideally suited for operation in electrically harsh environments or where cables can be plugged/unplugged. They are also immune to hi ...
... The ADM488/ADM489 are ruggedized RS-485 transceivers that operate from a single 5 V supply. They contain protection against radiated and conducted interference and are ideally suited for operation in electrically harsh environments or where cables can be plugged/unplugged. They are also immune to hi ...
automatic transformer winding resistance meter
... stability of readings of large delta connected transformers. Using the Windows Analysis Software (Optional Accessory) one can further analyse the Test data by comparing each channel graph with the other three, provide temperature correction for Aluminum and Copper, compare readings with previous val ...
... stability of readings of large delta connected transformers. Using the Windows Analysis Software (Optional Accessory) one can further analyse the Test data by comparing each channel graph with the other three, provide temperature correction for Aluminum and Copper, compare readings with previous val ...
PS22A79 < Dual-In-Line Package Intelligent Power Module >
... 1 :If control GND and power GND are patterned by common wiring, it may cause malfunction by fluctuation of power GND level. It is recommended to connect control GND and power GND at only a N1 point at which NU, NV, NW are connected to power GND line. 2 :It is recommended to insert a Zener diode D1 ( ...
... 1 :If control GND and power GND are patterned by common wiring, it may cause malfunction by fluctuation of power GND level. It is recommended to connect control GND and power GND at only a N1 point at which NU, NV, NW are connected to power GND line. 2 :It is recommended to insert a Zener diode D1 ( ...
Chap 21
... 37. The voltage supplied to an ac circuit is given by v = 120 sin(60t). What are the rms voltage and the frequency? A. 120 V, 60 Hz B. 120 V, 380 Hz C. 170 V, 9.5 Hz D. 85 V, 9.5 Hz E. 240 V, 30 Hz ...
... 37. The voltage supplied to an ac circuit is given by v = 120 sin(60t). What are the rms voltage and the frequency? A. 120 V, 60 Hz B. 120 V, 380 Hz C. 170 V, 9.5 Hz D. 85 V, 9.5 Hz E. 240 V, 30 Hz ...
Transient PSpice Analysis (7.4)
... • When the Precharge line is high (> 3V) and the Data line is low (~0V), transistor Q1 is on and the capacitor charges up to 3V. • If the Data line goes high after the capacitor is charged, then Q2 turns on and the capacitor discharges. ...
... • When the Precharge line is high (> 3V) and the Data line is low (~0V), transistor Q1 is on and the capacitor charges up to 3V. • If the Data line goes high after the capacitor is charged, then Q2 turns on and the capacitor discharges. ...
555 Timer IC Pin configuration
... • This integrated circuit can be used to generate stable time delays like monostable multivibrator, or it may be used as on oscillator like an astable multivibrator. It is an 8 pin dual-in- ...
... • This integrated circuit can be used to generate stable time delays like monostable multivibrator, or it may be used as on oscillator like an astable multivibrator. It is an 8 pin dual-in- ...
PS22A79
... 1 :If control GND and power GND are patterned by common wiring, it may cause malfunction by fluctuation of power GND level. It is recommended to connect control GND and power GND at only a N1 point at which NU, NV, NW are connected to power GND line. 2 :It is recommended to insert a Zener diode D1 ( ...
... 1 :If control GND and power GND are patterned by common wiring, it may cause malfunction by fluctuation of power GND level. It is recommended to connect control GND and power GND at only a N1 point at which NU, NV, NW are connected to power GND line. 2 :It is recommended to insert a Zener diode D1 ( ...
Datasheet
... The sequence of reading pressure and temperature as well as of performing the software compensation is depicted in Fig. 3 and Fig. 5. First Word1 to Word4 have to be read through the serial interface. This can be done once after reset of the microcontroller that interfaces to the MS5561. Next, the c ...
... The sequence of reading pressure and temperature as well as of performing the software compensation is depicted in Fig. 3 and Fig. 5. First Word1 to Word4 have to be read through the serial interface. This can be done once after reset of the microcontroller that interfaces to the MS5561. Next, the c ...
scanCONTROL 2700
... If the sensor is connected to a network adapter/switch that is capable of POE and if you also use the power supply of the multifunction port, these two power supplies have to be galvanically isolated. >> Damage of the sensor and/or the Ethernet card! -- A fixed IP address can be assigned. Use the ...
... If the sensor is connected to a network adapter/switch that is capable of POE and if you also use the power supply of the multifunction port, these two power supplies have to be galvanically isolated. >> Damage of the sensor and/or the Ethernet card! -- A fixed IP address can be assigned. Use the ...