• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Data Center v1.0 Author: Jay Park, Data Center Design Director
Data Center v1.0 Author: Jay Park, Data Center Design Director

... Surge Protection Devices (SPD) are incorporated into each switchboard. The SPD meets UL 1442 third edition category C3. Phase-to-phase and phase-to-ground protection is provided. Equipment monitoring interface: o o o o o o ...
Thermo Scientific EMCPro PLUS - Fisher Scientific
Thermo Scientific EMCPro PLUS - Fisher Scientific

... degradation when CM-I/OCD-HS is installed. Option CM-I/OCD-HS is recommended for data line frequencies greater than 1 kHz Eight lines – any line can be surged to any other line or ground 4.4 kV 200 V 1A AC or DC Selectable built-in clamps of 20V and 220V; external bias input for other clamp levels I ...
DC/DC power module 12V/0.92A/11W
DC/DC power module 12V/0.92A/11W

... outside the VO tolerance band will occur under the following conditions: Frequency range Voltage level 30...300 MHz 1.0 Vrms The signal is amplitude modulated with 1 kHz/80% and applied in both differential and common mode. ...
Using the AEA 20/20 TDR
Using the AEA 20/20 TDR

... 1) Write a SHORT 1 paragraph marketing advertisement for your Voltage Indicator, similar to (but shorter than) the description of the LM317 in its data sheet http://www.ti.com/lit/ds/symlink/lm117.pdf Be sure to specify the range of voltages it can indicate, the power supply it requires, and any oth ...
IXZ631DF18N50 - IXYS Colorado
IXZ631DF18N50 - IXYS Colorado

... designed for Class D, E, HF, and RF applications at up to 27 MHz, as well as other applications. The IXZ631DF18N50 in pulse mode can provide 95 A of peak current while producing voltage rise and fall times of less than 5 ns, and minimum pulse widths of 8 ns. The input of the driver is fully immune t ...
MPC5606E Microcontroller Data Sheet
MPC5606E Microcontroller Data Sheet

... Table 4 defines the pin list and muxing for the MPC5606E devices. Each row of Table 4 shows all the possible ways of configuring each pin, via “alternate functions”. The default function assigned to each pin after reset is the ALT0 function.Pins marked as external interrupt capable can also be used ...
1718 W. Mishawaka Rd., Elkhart, IN 46517 516.594
1718 W. Mishawaka Rd., Elkhart, IN 46517 516.594

... The No326S Preamplifier is a direct descendant of the critically acclaimed N o32 Reference Preamplifier. The No326S features audio circuits, controls, architecture and a phono-input option based on the No32. In fact, some audio circuits, such as the proprietary discrete volume attenuators, are ident ...
Value Flex – VF600-G2
Value Flex – VF600-G2

... The temperature of the LED modules must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label. ...
Operating Manual
Operating Manual

... Differential signals with RS422 or Push-pull HTL levels from other sources may also be connected to these devices. The modules are available with various wave lengths, level and supply voltage variants. The optical fiber modules are mainly used for signal transmission in environments with strong ele ...
AM42-0007 GaAs MMIC VSAT Power Amplifier, 2.0 W 14.0 - 14.5 GHz
AM42-0007 GaAs MMIC VSAT Power Amplifier, 2.0 W 14.0 - 14.5 GHz

BD37544FS
BD37544FS

STF724
STF724

... Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 ...
AVR2038: AT86RF231 Range Extension 8
AVR2038: AT86RF231 Range Extension 8

... 4.7 External Peripherals The RCB is equipped with two 50 mil connectors to place the board on a variety of expansion boards. The connectors provide access to all spare Atmel ATmega1281/V pins, including USART, TWI, ADC, PWM and external memory pins. The detailed pin mapping is shown in Table 4-2. Ta ...
FPGA Based Robotic Arm With Six Degrees of Freedom
FPGA Based Robotic Arm With Six Degrees of Freedom

360AMX AC Power Source Datasheet
360AMX AC Power Source Datasheet

... AC Power Sources, the 360AMX offers the same low output voltage noise and distortion, ease of installation, and high AC waveform fidelity as found in all of Pacific Power’s Linear AC Power Sources. Control and operational features provide a high degree of versatility and ease of use for applications ...
Powerline Home Automation System
Powerline Home Automation System

... A study done by Chan and Donaldson [3] shows that the signal attenuation is neither constant nor linear on the residential powerline over the 20-240 kHz band, as shown in figure 3. The main factor that causes the data signal to become attenuated is that the impedance along the line is very low and d ...
New Title - LydRommet
New Title - LydRommet

... 4. Before connecting the equipment to power, check that the AC mains voltage stated on the supplied power supply is identical to the AC mains voltage available where you will use the equipment. 5. Operate the equipment with the supplied power supply with an output voltage of 12 VDC. Using adapters w ...
Ground and Short Circuit
Ground and Short Circuit

... Grounding and short circuit at one of the next poles is allowed in case of pole breakers. For works on cables, isolated lines, electrical equipment, which is connected over spur cables or isolated lines (i.e. motors) grounding and short-circuit is not mandatory. But all switching locations must be g ...
STL128D
STL128D

... Features ...
CMOS Inverter Characteristics
CMOS Inverter Characteristics

ap® physics 1 2015 scoring guidelines
ap® physics 1 2015 scoring guidelines

... Part (a) earned 4 points. The only point not earned is the one for connecting a voltmeter in parallel with the lightbulb. Parts (b)(i) and (b)(ii) earned full credit for a net of 2 points. Although the voltmeters are not connected correctly, in part (b)(ii) the student does show understanding that a ...
Manual - Ashly Audio
Manual - Ashly Audio

... another unit is connected to the Slave Data in/out connector. Master Output and Channel Pass Through The VCM-88C can be used as an eight-in/one out remote level control for personal monitor mixing using the Master Output. Multiple VCM88C units can be daisy chained to produce several unique mixes fro ...
Switch Mode DC Power Supplies SEC-1212 SEC-1223
Switch Mode DC Power Supplies SEC-1212 SEC-1223

... Digital Devices for Residential Installations. The corresponding European standard is EN55022, Class “B” & EN610000-3-2, 3. ...
ademco 269r/270r
ademco 269r/270r

... Run the wiring from the control panel to the device, through the opening in the case back as shown in Figure 3. Wire the device for a normally closed or a normally open loop with no EOL resistor or for a normally-closed or a normally open loop with an EOL resistor as shown in figure 3, detail A and ...
60V, 3A Step-Down DC/DC Converter Has Low Dropout and 100µA
60V, 3A Step-Down DC/DC Converter Has Low Dropout and 100µA

... quiescent current at zero load drains batteries in applications that spend long periods of time at minimum load current. One common solution for reducing quiescent current and improving battery run-time is a shutdown function, but shutdown drops the output voltage to zero. Shutdown is not acceptable ...
< 1 ... 924 925 926 927 928 929 930 931 932 ... 1306 >

Immunity-aware programming

When writing firmware for an embedded system, immunity-aware programming refers to programming techniques which improve the tolerance of transient errors in the program counter or other modules of a program that would otherwise lead to failure. Transient errors are typically caused by single event upsets, insufficient power, or by strong electromagnetic signals transmitted by some other ""source"" device.Immunity-aware programming is an example of defensive programming and EMC-aware programming. Although most of these techniques apply to the software in the ""victim"" device to make it more reliable, a few of these techniques apply to software in the ""source"" device to make it emit less unwanted noise.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report