• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Alberta Reliability Standard Automatic Generation Control BAL-005-AB-0.2b
Alberta Reliability Standard Automatic Generation Control BAL-005-AB-0.2b

... (b) records of checking and calibratingon against a common reference; (c) where the manufacturer’s specification does not require calibration of these devices, records of check and cross-checking against a properly calibrated equipment. MR21 Evidence of adhering to the minimum values for measuring d ...
one-phase static meters ze 110
one-phase static meters ze 110

... by strict SW guard – “access level 3” as given in the standard. If you want to enter the mode you must know the password (stored in configuration of the unit) and cryptographic algorithm. A random number generated by the unit is used at the entrance of the algorithm so that it could not be found on ...
myDaq Biomedical Instrument
myDaq Biomedical Instrument

... the myDAQ that will directly compete with the BioPac at a 40x price margin The board should provide the necessary connections and LabView interface to allow for measurements done in an introductory Biomedical Engineering course at Iowa State University ...
Mentor preliminary introduction
Mentor preliminary introduction

... performed from the AIC thus avoiding the use of an external computer. • SMART TEST TOOLS preprogrammed test routines for relay functions, Transducers, and Meters. • RESULTS MANAGER to save and manage obtained ...
MAX6607/MAX6608 Low-Voltage Analog Temperature Sensors in SC70 and SOT23 Packages General Description
MAX6607/MAX6608 Low-Voltage Analog Temperature Sensors in SC70 and SOT23 Packages General Description

... The thermal path between the plastic package and the die is not as good as the path through the leads, so the MAX6607/MAX6608, like all temperature sensors in plastic packages, are less sensitive to the temperature of the surrounding air than they are to the temperature of their leads. They can be s ...
PDF
PDF

lecture1428911481
lecture1428911481

...  QUANTITIES, UNITS AND STANDARDS :Definitions:A quantity is a quantifiable or assignable property ascribed to phenomena, bodies, or substances. Examples are speed of a car and mass of an electron. A physical quantity is a quantity that can be used in the mathematical equations of science and techno ...
D44H11
D44H11

HI200-1.pdf
HI200-1.pdf

... All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes ...
ECG Quick Reference Guide
ECG Quick Reference Guide

... rhythmic or sporadic), electro­magnetic interference (EMI), and noise from other electronic components that couple into the input. Some of the noise can be cancelled with a high-input-impedance instrumentation amplifier (INA), like the INA333 or INA118, which removes the AC line noise common to both ...
Easy solar-panel maximum-power-point tracking for pulsed
Easy solar-panel maximum-power-point tracking for pulsed

TS4100,01,02 - Silicon Labs
TS4100,01,02 - Silicon Labs

... TS4100/01/02 Data Sheet "Rail-to-Rail Plus"™, 1% RON Flatness, 0.8 V to 5.25 V Analog ...
II. Characteristics Of Comparator 1. Minimum input slew rate: Slew
II. Characteristics Of Comparator 1. Minimum input slew rate: Slew

MOSFET Driver with Dual Outputs for Synchronous Buck Converters
MOSFET Driver with Dual Outputs for Synchronous Buck Converters

... The high−side driver is designed to drive a floating low RDS(on) N−channel MOSFET. The gate voltage for the high side driver is developed by a bootstrap circuit referenced to Switch Node (SW) pin. The bootstrap circuit is comprised of an external diode, and an external bootstrap capacitor. When the ...
Syllabus Sample Two - Asnuntuck Community College
Syllabus Sample Two - Asnuntuck Community College

... q Connect a transistor into an electronic circuit. q Discuss the polarity connections for different types of transistors. q Draw transistor symbols for both NPN and PNP type transistors. q Discuss the use of transistors in a switching application. q Connect a transistor into a circuit and use i ...
styrofoam-cutters
styrofoam-cutters

... Power input: 400 W max. Infinitely variable working temperature. Continuous operation. Protective insulation. Supply cord 2m with European-type plug (US-type plug) A flexible 2m cord connects blade holder M with unit (max 3m cable also available) Easily interchangeable long-life blade ...
Product Specification
Product Specification

... (3) If less the 16 bits of SCL are input while CS is low, the transferred data is ignored. The read operation interrupt. ...
BoxX User`s Manual
BoxX User`s Manual

... 1. LCD Display: For all controls of the BoxX a display including operating keys is available. It is mounted on the front side of the BoxX and is showing the status of inputs and outputs and the time. Through it, different system parameter can be set. If no display is used, the connector is covered w ...
The dB in Communications
The dB in Communications

... dBuV This is a common form for specifying input RF levels to a communications receiver. This is called dB microvolt where 1 microvolt = 1*10E-6V. dbV While this dB term is defined, it is rarely used in defining communication systems. The dB value is obtained with respect to 1 Volt. dB/bit This is a ...
LB1870, 1870M Three-Phase Brushless Motor Driver Overview Package Dimensions
LB1870, 1870M Three-Phase Brushless Motor Driver Overview Package Dimensions

... holding the hall amplifier output amplitude fixed. This pin outputs the three-phase hall signal envelope, and is smoothed with a capacitor (about 0.1 µF) since it has ripple. When the hall input amplitude is small, the AGC pin potential will rise, and when the input amplitude is large, the AGC pin p ...
Télécharger
Télécharger

... standard feature in a line protective relay. From now on, expect line protective relays to offer traveling-wave fault locating with ten-fold better accuracy. The SEL-T400L incorporates a single-ended traveling-wave fault-locating method, which calculates the fault location by analyzing only the loca ...
applications of gps in power engineering
applications of gps in power engineering

... generators, etc.)  the identification of accurate model/parameter is a very important and tough task for the power system analysis and control.  difficulty: large number of power system components having timevarying characteristics.  synchronized disturbances record and replay  this task is like ...
NTUST-EE-2013S-Lectures
NTUST-EE-2013S-Lectures

... If the voltage in the previous example is 10 V, sketch the current phasor diagram. The admittance diagram from the previous example is shown for reference. The current phasor diagram can be found from Ohm’s law. Multiply each admittance phasor by 10 V. BC = 0.628 mS Y= 1.18 mS G = 1.0 mS ...
DAC0808 8-Bit D/A Converter 8-Bit D/A
DAC0808 8-Bit D/A Converter 8-Bit D/A

... Note 2: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not apply when operating the device beyond its specified operating conditions. Note 3: Range control is not required. Note 4: The maximum power dissipation must be der ...
DATA  SHEET BCX71 series PNP general purpose transistors
DATA SHEET BCX71 series PNP general purpose transistors

< 1 ... 852 853 854 855 856 857 858 859 860 ... 1306 >

Immunity-aware programming

When writing firmware for an embedded system, immunity-aware programming refers to programming techniques which improve the tolerance of transient errors in the program counter or other modules of a program that would otherwise lead to failure. Transient errors are typically caused by single event upsets, insufficient power, or by strong electromagnetic signals transmitted by some other ""source"" device.Immunity-aware programming is an example of defensive programming and EMC-aware programming. Although most of these techniques apply to the software in the ""victim"" device to make it more reliable, a few of these techniques apply to software in the ""source"" device to make it emit less unwanted noise.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report