10-Bit, 40MHz, Current/Voltage-Output DACs General Description Features
... (0.5µs) from standby mode to full DAC operation facilitates power conservation by activating the DAC only when required. The MAX5181/MAX5184 are available in 24-pin QSOP packages and are specified for the extended (-40°C to +85°C) temperature range. Additionally, the MAX5184 is also available in a 2 ...
... (0.5µs) from standby mode to full DAC operation facilitates power conservation by activating the DAC only when required. The MAX5181/MAX5184 are available in 24-pin QSOP packages and are specified for the extended (-40°C to +85°C) temperature range. Additionally, the MAX5184 is also available in a 2 ...
MT-097: 高速逻辑的应用(英文)
... Typical CMOS input capacitance is 5 pF to 10 pF. Locate the series resistor close to the driving gate. The resistor minimizes transient currents and may eliminate the necessity of using transmission line techniques. The value of the resistor should be chosen such that the rise and fall times at the ...
... Typical CMOS input capacitance is 5 pF to 10 pF. Locate the series resistor close to the driving gate. The resistor minimizes transient currents and may eliminate the necessity of using transmission line techniques. The value of the resistor should be chosen such that the rise and fall times at the ...
DS1088C Fixed-Frequency EconoOscillator™ General Description Features
... oscillator output for power-sensitive applications. The power-down pin must remain low for at least two output frequency cycles plus 10µs for deglitching purposes. On power-up, the output is disabled until power is stable and the voltage-controlled oscillator has generated 512 clock cycles. ...
... oscillator output for power-sensitive applications. The power-down pin must remain low for at least two output frequency cycles plus 10µs for deglitching purposes. On power-up, the output is disabled until power is stable and the voltage-controlled oscillator has generated 512 clock cycles. ...
F-Pickup 2,5 kW, 560 V DC - Conductix
... This symbol can be found in several places of the operating instructions where special care has to be taken due to voltage presence which is a potential danger to the life of people. Please observe these instructions and be careful in those cases. Please carry out all health and safety regulations t ...
... This symbol can be found in several places of the operating instructions where special care has to be taken due to voltage presence which is a potential danger to the life of people. Please observe these instructions and be careful in those cases. Please carry out all health and safety regulations t ...
Data Converter Specifications
... ? Use signal generators with low jitter but also preserve the feature in the phase generator. ? The PCB traces leading the clock must be short with a solid ground plane underneath for forming a microstrip transmission line and enables impedance matching. ? When low-speed data converters use external ...
... ? Use signal generators with low jitter but also preserve the feature in the phase generator. ? The PCB traces leading the clock must be short with a solid ground plane underneath for forming a microstrip transmission line and enables impedance matching. ? When low-speed data converters use external ...
Oscilloscope Controls
... Trigger controls compare the signal edge to user-set levels and polarity (+/- slope) Trigger Level – determines where on signal edge the trigger point occurs Trigger Slope – determines whether trigger point occurs on rising or falling edge. ...
... Trigger controls compare the signal edge to user-set levels and polarity (+/- slope) Trigger Level – determines where on signal edge the trigger point occurs Trigger Slope – determines whether trigger point occurs on rising or falling edge. ...
APPLICATION NOTE
... The TDA5051 is a complete ASK MODEM dedicated to data transmission on power line network, requiring very few external components. It could be also used on any two wire network for exchanging informations by means of ASK carrier current technique (DC or AC network). The use of a digital structure for ...
... The TDA5051 is a complete ASK MODEM dedicated to data transmission on power line network, requiring very few external components. It could be also used on any two wire network for exchanging informations by means of ASK carrier current technique (DC or AC network). The use of a digital structure for ...
... Users can select between four monitors: SE-325, SE-330, SE-330AU, and SE-330HV. Enter the system’s line-to-line voltage or line-toneutral voltage. Once it has been entered, the other system voltage field will populate automatically. Enter either the let-through current of the neutralgrounding resist ...
Evaluation Board User Guide UG-223
... To install the evaluation software, do the following: 1. Insert the AD7193 Evaluation Kit CD into the CD-ROM drive of your PC. The Evaluation Software Installation Wizard should start automatically. If it does not start automatically, navigate to the AD7193 Evaluation Kit CD on your PC and click Set ...
... To install the evaluation software, do the following: 1. Insert the AD7193 Evaluation Kit CD into the CD-ROM drive of your PC. The Evaluation Software Installation Wizard should start automatically. If it does not start automatically, navigate to the AD7193 Evaluation Kit CD on your PC and click Set ...
Understanding the I2C Bus
... communicate with slave devices. A slave may not transmit data unless it has been addressed by the master. Each device on the I2C bus has a specific device address to differentiate between other devices that are on the same I2C bus. Many slave devices will require configuration upon startup to set th ...
... communicate with slave devices. A slave may not transmit data unless it has been addressed by the master. Each device on the I2C bus has a specific device address to differentiate between other devices that are on the same I2C bus. Many slave devices will require configuration upon startup to set th ...
mbedlab1a
... A lot of development time is saved by using AnalogIn, there is no need to find and understand all of these hardware details in the LPC1768 User’s Manual to get the I/O device to work. This is why I/O device drivers are typically used in larger systems. Since temperature changes slowly, it is enginee ...
... A lot of development time is saved by using AnalogIn, there is no need to find and understand all of these hardware details in the LPC1768 User’s Manual to get the I/O device to work. This is why I/O device drivers are typically used in larger systems. Since temperature changes slowly, it is enginee ...
AD7951 数据手册DataSheet下载
... Process control Medical instruments High speed data acquisition Digital signal processing Instrumentation Spectrum analysis ATE ...
... Process control Medical instruments High speed data acquisition Digital signal processing Instrumentation Spectrum analysis ATE ...
Low-noise computer-controlled current source for quantum
... generate with voltage dividers on the board. We designed the current source without a feedback loop. Such a loop might well induce additional 1 / f noise, and is not required for our purposes since the drift over the time of a spectral measurement, typically 10 min, is insignificant. We compensate f ...
... generate with voltage dividers on the board. We designed the current source without a feedback loop. Such a loop might well induce additional 1 / f noise, and is not required for our purposes since the drift over the time of a spectral measurement, typically 10 min, is insignificant. We compensate f ...
tps72501.pdf
... These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. ...
... These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. ...
Arduino Control Flicker System Instructions DOCX
... Connecting the capacitors 1. Take one of the capacitors and identify the positive leg. Usually, the positive leg is the longer leg. 2. In row 5, connect the positive leg of the capacitor to power (red bus) and connect the negative leg of the capacitor to ground (blue bus). If your capacitor legs are ...
... Connecting the capacitors 1. Take one of the capacitors and identify the positive leg. Usually, the positive leg is the longer leg. 2. In row 5, connect the positive leg of the capacitor to power (red bus) and connect the negative leg of the capacitor to ground (blue bus). If your capacitor legs are ...
ADS1201 数据资料 dataSheet 下载
... weight but not the internal noise, resulting in increased signal-to-noise ratio. Likewise, lower reference voltages will decrease the signal-to-noise ratio. ...
... weight but not the internal noise, resulting in increased signal-to-noise ratio. Likewise, lower reference voltages will decrease the signal-to-noise ratio. ...
IOM MICRONEX (V2.2)
... The supply must be isolated before opening the luminaire. In most instances the faults are simple, namely loose or broken connections, unserviceable lamps or open circuit control gear. Control gear will not normally go open circuit unless it has first over-heated; the signs of this are obvious, bein ...
... The supply must be isolated before opening the luminaire. In most instances the faults are simple, namely loose or broken connections, unserviceable lamps or open circuit control gear. Control gear will not normally go open circuit unless it has first over-heated; the signs of this are obvious, bein ...
BYPASS/1A Circuits - Electric Forklift Forklift Electronics
... The negative side is connected to a timer circuit, either within the main control card or an auxiliary timer card used specifically for bypass operation. Before bypass is called for, by the bypass microswitch, the timer circuit is shut off so the bypass contactor will not energize during the shut of ...
... The negative side is connected to a timer circuit, either within the main control card or an auxiliary timer card used specifically for bypass operation. Before bypass is called for, by the bypass microswitch, the timer circuit is shut off so the bypass contactor will not energize during the shut of ...
- Kewtech
... instructions or safety procedures. 1.2 It is essential to read and understand the safety rules contained in the instructions. They must always be observed when using the instrument. 1.3 This meter has been designed with your safety in mind. However, no design can completely protect against incorrect ...
... instructions or safety procedures. 1.2 It is essential to read and understand the safety rules contained in the instructions. They must always be observed when using the instrument. 1.3 This meter has been designed with your safety in mind. However, no design can completely protect against incorrect ...