GC3510651086
... (DVR). The control of DVR that injects a voltage in series with a distribution feeder is presented. DVR is a power electronic controller that can protect sensitive loads from disturbances in supply system. DVR can regulate the voltage at the load. The design issues, implementation procedures and sys ...
... (DVR). The control of DVR that injects a voltage in series with a distribution feeder is presented. DVR is a power electronic controller that can protect sensitive loads from disturbances in supply system. DVR can regulate the voltage at the load. The design issues, implementation procedures and sys ...
AD9273 - Analog Devices
... Changes to LNA Noise Section .................................................... 24 Changes to Input Overload Protection Section and Figure 44 ....... 25 Changes to Figure 48...................................................................... 28 Changes to Figure 49 and Figure 50................. ...
... Changes to LNA Noise Section .................................................... 24 Changes to Input Overload Protection Section and Figure 44 ....... 25 Changes to Figure 48...................................................................... 28 Changes to Figure 49 and Figure 50................. ...
DRV2667 - Texas Instruments
... memory to store and recall waveforms with minimal latency as well as an advanced waveform synthesizer to construct complex haptic waveforms with minimal memory usage. This provide a means of hardware acceleration, relieving the host processor of haptic generation duties as well as minimizing bus tra ...
... memory to store and recall waveforms with minimal latency as well as an advanced waveform synthesizer to construct complex haptic waveforms with minimal memory usage. This provide a means of hardware acceleration, relieving the host processor of haptic generation duties as well as minimizing bus tra ...
GTM 8-6-8 product description r-1-09
... SMS (Short Message System, 160 characters) to send on request periodical or simple queries, as well they are able to use a permanent connection (“DATA connection”, only on GTM 8-6-8 version 2) to transmit all the programming messages for software applications through the world wide GSM network. In t ...
... SMS (Short Message System, 160 characters) to send on request periodical or simple queries, as well they are able to use a permanent connection (“DATA connection”, only on GTM 8-6-8 version 2) to transmit all the programming messages for software applications through the world wide GSM network. In t ...
LAPP IPMC Mezzanine LAPP Intelligent Platform Management Controller Mezzanine Version V1.5
... Figure 3 shows the AMC management architecture on an ATCA board. The management bus IPMB-L is chained to all AMCs. This bus is controlled for each AMC by a buffer that can be enables or disabled by the IPMC in order to isolate the AMC. The IPMC receives the PS1# signal indicating that an AMC is conn ...
... Figure 3 shows the AMC management architecture on an ATCA board. The management bus IPMB-L is chained to all AMCs. This bus is controlled for each AMC by a buffer that can be enables or disabled by the IPMC in order to isolate the AMC. The IPMC receives the PS1# signal indicating that an AMC is conn ...
The LM3900 A New Current-Differencing Quad of Plus or Minus
... Like the standard IC op amp, the LM3900 has a wide range of applications. A new approach must be taken to design circuits with this ‘‘Norton’’ amplifier and the object of this note is to present a variety of useful circuits to indicate how conventional and unique new applications can be designedÐesp ...
... Like the standard IC op amp, the LM3900 has a wide range of applications. A new approach must be taken to design circuits with this ‘‘Norton’’ amplifier and the object of this note is to present a variety of useful circuits to indicate how conventional and unique new applications can be designedÐesp ...
Stakeholder Comparison Comment Rationale Matrix 2012-09-06 AESO AUTHORITATIVE DOCUMENT PROCESS
... applied on the bulk system-end of transmission lines that serve load remote to the system so they do not operate at or below 115% of the maximum current flow from the system to the load under any system configuration. 9. Set transmission line relays applied on the load-end of transmission lines that ...
... applied on the bulk system-end of transmission lines that serve load remote to the system so they do not operate at or below 115% of the maximum current flow from the system to the load under any system configuration. 9. Set transmission line relays applied on the load-end of transmission lines that ...
S280-70-3_10000
... Control programming settings and parameters—including event recorder—are stored in non-volatile memory and retained upon loss of control power. The time/date clock will continue to operate for approximately 30 days after loss of control power. Phase B (Ø) is the factory default phase. Unless changed ...
... Control programming settings and parameters—including event recorder—are stored in non-volatile memory and retained upon loss of control power. The time/date clock will continue to operate for approximately 30 days after loss of control power. Phase B (Ø) is the factory default phase. Unless changed ...
DM-III Power Quality Recorder Product Manual
... The DM-III represents a new approach to the world of electrical measurement. Computer assisted instruments such as the DM-III permit an easy and fast analysis of a huge quantity of data. ...
... The DM-III represents a new approach to the world of electrical measurement. Computer assisted instruments such as the DM-III permit an easy and fast analysis of a huge quantity of data. ...
A Low-Power High-Precision Comparator With Time-Domain Bulk-Tuned Offset Cancellation
... linear pre-amplifiers and cancel the offset by negative feedback in auto-zeroing phase [5]. This scheme, however, requires high bandwidth amplifiers with considerable gain, which will inevitably lead to large power consumption. And its effectiveness will degrade with the reduction of drain resistanc ...
... linear pre-amplifiers and cancel the offset by negative feedback in auto-zeroing phase [5]. This scheme, however, requires high bandwidth amplifiers with considerable gain, which will inevitably lead to large power consumption. And its effectiveness will degrade with the reduction of drain resistanc ...
LP5912 500-mA Low-Noise, Low-IQ LDO (Rev. D)
... Output Automatic Discharge for Fast Turnoff Power-Good Output With 140-µs Typical Delay Internal Soft-Start to Limit the In-rush Current –40°C to +125°C Operating Junction Temperature Range ...
... Output Automatic Discharge for Fast Turnoff Power-Good Output With 140-µs Typical Delay Internal Soft-Start to Limit the In-rush Current –40°C to +125°C Operating Junction Temperature Range ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
... topologies use single inductor compared to the two inductors used in the proposed converter. However, there are several disadvantages in these Two H- Bridge converters. In H-bridge converters, there are two devices in the conduction path during charge or discharge of the boost inductor. But in the p ...
... topologies use single inductor compared to the two inductors used in the proposed converter. However, there are several disadvantages in these Two H- Bridge converters. In H-bridge converters, there are two devices in the conduction path during charge or discharge of the boost inductor. But in the p ...
2 Geo Direct PWM Amplifier
... amplifiers interface directly with Delta Tau’s PMAC2 or PMAC3 style digital ASICs, typically found in the axis expansion cards inside a Turbo or Power UMAC rack. The Geo Direct PWM Drive takes the actual power-transistor on/off signals from PMAC, while providing digital phase-current feedback and st ...
... amplifiers interface directly with Delta Tau’s PMAC2 or PMAC3 style digital ASICs, typically found in the axis expansion cards inside a Turbo or Power UMAC rack. The Geo Direct PWM Drive takes the actual power-transistor on/off signals from PMAC, while providing digital phase-current feedback and st ...
EPC 10 USB Manual - Warner Instruments
... available from the current monitor circuitry, and the integrated transient cancellation (automatically if desired) and series-resistance compensation functions. In current clamp mode, the EPC 10 USB pre-amplifier acts as an ’voltage-follower’, similar to classical microelectrode amplifiers, which gu ...
... available from the current monitor circuitry, and the integrated transient cancellation (automatically if desired) and series-resistance compensation functions. In current clamp mode, the EPC 10 USB pre-amplifier acts as an ’voltage-follower’, similar to classical microelectrode amplifiers, which gu ...
CD54HC4046A, CD74HC4046A, CD54HCT4046A
... frequency. At this stable point the voltage on C2 remains constant as the PC2 output is in three-state and the VCO input at pin 9 is a high impedance. Also in this condition, the signal at the phase comparator pulse output (PCPOUT) is a HIGH level and so can be used for indicating a locked condition ...
... frequency. At this stable point the voltage on C2 remains constant as the PC2 output is in three-state and the VCO input at pin 9 is a high impedance. Also in this condition, the signal at the phase comparator pulse output (PCPOUT) is a HIGH level and so can be used for indicating a locked condition ...
ARC2016U_Bank Alarm Controller Quick Start Guide V1.2.0 201509
... Do not use power line other than the one specified. Please use it properly. Otherwise, it may cause fire or electric shock. ...
... Do not use power line other than the one specified. Please use it properly. Otherwise, it may cause fire or electric shock. ...
Triple 8-Bit, 80 MSPS Video D/A Converter With
... channel or on all three channels, depending on the setting of INS3_INT. By combining the SYNC and SYNC_T control inputs, either bi-level negative going pulses or tri-level pulses can be generated. Depending on the timing controls for these signals, both horizontal and vertical sync signals can be ge ...
... channel or on all three channels, depending on the setting of INS3_INT. By combining the SYNC and SYNC_T control inputs, either bi-level negative going pulses or tri-level pulses can be generated. Depending on the timing controls for these signals, both horizontal and vertical sync signals can be ge ...