linear regulators
... 1. Simple/low cost solutions. Linear regulator or LDO solutions are simple and easy to use, especially for low power applications with low output current where thermal stress is not critical. No external power inductor is required. 2. Low noise/low ripple applications. For noise-sensitive applicatio ...
... 1. Simple/low cost solutions. Linear regulator or LDO solutions are simple and easy to use, especially for low power applications with low output current where thermal stress is not critical. No external power inductor is required. 2. Low noise/low ripple applications. For noise-sensitive applicatio ...
P3Z22V10 3V zero power, TotalCMOS™, universal PLD device
... 3V zero power, TotalCMOS, universal PLD device ...
... 3V zero power, TotalCMOS, universal PLD device ...
Unit 21
... quantity being measured. Basically it consists of a current-measuring moving-coil meter with appropriate internal resistors brought into circuit by a range switch. Its operation was considered in section 2.7, where we saw that it can be used to measure current and voltage, both d.c. and a.c., as wel ...
... quantity being measured. Basically it consists of a current-measuring moving-coil meter with appropriate internal resistors brought into circuit by a range switch. Its operation was considered in section 2.7, where we saw that it can be used to measure current and voltage, both d.c. and a.c., as wel ...
AAT3687 数据资料DataSheet下载
... The AAT3687 is a highly integrated single-cell lithiumion/polymer battery charger IC designed to operate with standard AC adapter input sources, while requiring a minimum number of external components. The AAT3687 precisely regulates battery charge voltage and current for 4.2V lithium-ion/polymer ba ...
... The AAT3687 is a highly integrated single-cell lithiumion/polymer battery charger IC designed to operate with standard AC adapter input sources, while requiring a minimum number of external components. The AAT3687 precisely regulates battery charge voltage and current for 4.2V lithium-ion/polymer ba ...
UNH InterOperability Lab
... – When COMINIT is received in response to COMRESET (associated with entry into state HP2B:HR_AwaitNoCOMINIT) • Shadow Status register value shall be set to FFh or 80h to reflect that a device is attached ...
... – When COMINIT is received in response to COMRESET (associated with entry into state HP2B:HR_AwaitNoCOMINIT) • Shadow Status register value shall be set to FFh or 80h to reflect that a device is attached ...
Installation and Operating Instructions
... comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not install ...
... comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not install ...
Digital Oscilloscope Adapter unit for a PC
... the analog signal, we try to design an adapter unit that is capable of the transferring of analog data to computer in digital form via USB interface. In addition to data transfer, our design includes adjustments of the received data. The approach that we have followed is first search, then implement ...
... the analog signal, we try to design an adapter unit that is capable of the transferring of analog data to computer in digital form via USB interface. In addition to data transfer, our design includes adjustments of the received data. The approach that we have followed is first search, then implement ...
P84024
... Current” for an individual strobe (across the expected operating voltage range of the strobe) or the highest value of “Rated Inrush current” or “Rated Peak current” (whichever is higher) of an individual strobe (across the expected operating voltage range of the strobe) then multiply the value by th ...
... Current” for an individual strobe (across the expected operating voltage range of the strobe) or the highest value of “Rated Inrush current” or “Rated Peak current” (whichever is higher) of an individual strobe (across the expected operating voltage range of the strobe) then multiply the value by th ...
Control System for Electromagnet Power Supplies
... There are a number of CAN application level protocols. A structure and resources of chosen microprocessor don’t prevent to implement one of them in our devices. But the use of many CAN-devices requires us to reduce traffic as much as possible. This leads us to the possible use of CAN message objects ...
... There are a number of CAN application level protocols. A structure and resources of chosen microprocessor don’t prevent to implement one of them in our devices. But the use of many CAN-devices requires us to reduce traffic as much as possible. This leads us to the possible use of CAN message objects ...
1771-2.13, Allen-Bradley Analog Input Module (12
... several different ways: 1) the diagnostics LED will illuminate: 2) certain bits in the channel word will be set: or 3)a combination of the two. The LED can be examined by removing the right-hand snap off cover on the front of the module (figure 4). The LED will be on under these conditions: ...
... several different ways: 1) the diagnostics LED will illuminate: 2) certain bits in the channel word will be set: or 3)a combination of the two. The LED can be examined by removing the right-hand snap off cover on the front of the module (figure 4). The LED will be on under these conditions: ...
Process Bus Solution An IEC 61850 Process Bus Solution
... samples per cycle is used for high-speed functions such as power quality monitoring. Separate SV streams must be synchronized to a common time base when being used for the same function. SV applications typically require an accuracy of <1µs which is accomplished by using a precise one pulse per seco ...
... samples per cycle is used for high-speed functions such as power quality monitoring. Separate SV streams must be synchronized to a common time base when being used for the same function. SV applications typically require an accuracy of <1µs which is accomplished by using a precise one pulse per seco ...
open switch fault diagnosis in three phase inverter using
... The voltage source inverter (VSI) is one of the most used circuit configurations for speed control of three-phase induction motors. The main objective of inverter is to produce an ac output waveform from a dc power supply. A fixed dc input voltage is given to the inverter and a controlled ac output ...
... The voltage source inverter (VSI) is one of the most used circuit configurations for speed control of three-phase induction motors. The main objective of inverter is to produce an ac output waveform from a dc power supply. A fixed dc input voltage is given to the inverter and a controlled ac output ...
WAKE UP AND SMELL THE FUNCTIONS
... distributed, posted, or reproduced in any form by digital or mechanical means without prior written permission of the publisher. WAKE UP AND SMELL THE FUNCTIONS ...
... distributed, posted, or reproduced in any form by digital or mechanical means without prior written permission of the publisher. WAKE UP AND SMELL THE FUNCTIONS ...
LTC1732-4
... of the battery voltage, provided the previous battery voltage exceeded 3.9V before the timer expired. After a complete charge cycle has occurred (VBAT > 3.9V), and the battery remains connected to the charger, a new charge cycle will begin if the battery voltage drops below 3.8V because of a load on ...
... of the battery voltage, provided the previous battery voltage exceeded 3.9V before the timer expired. After a complete charge cycle has occurred (VBAT > 3.9V), and the battery remains connected to the charger, a new charge cycle will begin if the battery voltage drops below 3.8V because of a load on ...
MAX6690 2°C Accurate Remote/Local Temperature Sensor with SMBus Serial Interface General Description
... mode. The adjustable conversion rate allows the user to optimize supply current and temperature update rate to match system needs. When the conversion rate is faster than 1Hz, the conversion results are available as a 7-bitplus-sign byte with a 1°C LSB. When the conversion rate is 1Hz or slower, the ...
... mode. The adjustable conversion rate allows the user to optimize supply current and temperature update rate to match system needs. When the conversion rate is faster than 1Hz, the conversion results are available as a 7-bitplus-sign byte with a 1°C LSB. When the conversion rate is 1Hz or slower, the ...
Picoammeter/ Voltage Source
... • Rear panel triax input. This allows the picoammeter to be used in floating operation, up to 500V. When not floating, the addition of a triax to BNC adapter allows inexpensive, easy-to-use BNC cables to be employed, rather than more expensive triaxial cables. • RS-232 and IEEE-488 interfaces. These ...
... • Rear panel triax input. This allows the picoammeter to be used in floating operation, up to 500V. When not floating, the addition of a triax to BNC adapter allows inexpensive, easy-to-use BNC cables to be employed, rather than more expensive triaxial cables. • RS-232 and IEEE-488 interfaces. These ...
AK8153A - Asahi Kasei Microdevices
... Note1) A critical component is one whose failure to function or perform may reasonably be expected to result, whether directly or indirectly, in the loss of the safety or effectiveness of the device or system containing it, and which must therefore meet very high standards of performance and reliabi ...
... Note1) A critical component is one whose failure to function or perform may reasonably be expected to result, whether directly or indirectly, in the loss of the safety or effectiveness of the device or system containing it, and which must therefore meet very high standards of performance and reliabi ...
DS2731 Cache-Memory Battery-Backup Management IC General Description Features
... specifications and a safety timer prevents the continued charging of a damaged cell. Switchover to battery backup is initiated by an internal comparator and occurs automatically when a sensed input voltage drops below 2.93V. The power failure switching circuitry can be disabled by the user. Memory v ...
... specifications and a safety timer prevents the continued charging of a damaged cell. Switchover to battery backup is initiated by an internal comparator and occurs automatically when a sensed input voltage drops below 2.93V. The power failure switching circuitry can be disabled by the user. Memory v ...
FSQ500L Compact, Green Mode, Fairchild Power Switch (FPS™) Features
... control, as shown in Figure 16. An opto-coupler (such as the FOD817A) and shunt regulator (such as the KA431) are typically used to implement the feedback network. Comparing the feedback voltage with the voltage across the Rsense resistor makes it possible to control the switching duty cycle. When t ...
... control, as shown in Figure 16. An opto-coupler (such as the FOD817A) and shunt regulator (such as the KA431) are typically used to implement the feedback network. Comparing the feedback voltage with the voltage across the Rsense resistor makes it possible to control the switching duty cycle. When t ...