PGA204,205 - Texas Instruments
... Figure 1 shows the basic connections required for operation of the PGA204/205. Applications with noisy or high impedance power supplies may require decoupling capacitors close to the device pins as shown. The output is referred to the output reference (Ref) terminal which is normally grounded. This ...
... Figure 1 shows the basic connections required for operation of the PGA204/205. Applications with noisy or high impedance power supplies may require decoupling capacitors close to the device pins as shown. The output is referred to the output reference (Ref) terminal which is normally grounded. This ...
659 5-kV Detector Bias Supply
... or ionization chambers. It can be used with any detector that draws less than 100 µA of current, and whose gain is insensitive to the applied voltage. The output voltage is continuously adjustable from zero to full scale with a calibrated and locking 5-turn dial. Separate outputs are provided for th ...
... or ionization chambers. It can be used with any detector that draws less than 100 µA of current, and whose gain is insensitive to the applied voltage. The output voltage is continuously adjustable from zero to full scale with a calibrated and locking 5-turn dial. Separate outputs are provided for th ...
MAX2754 1.2GHz VCO with Linear Modulation Input General Description
... Maximum variation in the modulation sensitivity from its average value over the guaranteed frequency limits. Bandwidth is defined as the point where the response to the modulation port is 0.707 times the low-frequency response. Bandwidth limits on the modulation input for a 1Vp-p sine wave. Common-m ...
... Maximum variation in the modulation sensitivity from its average value over the guaranteed frequency limits. Bandwidth is defined as the point where the response to the modulation port is 0.707 times the low-frequency response. Bandwidth limits on the modulation input for a 1Vp-p sine wave. Common-m ...
Hydraulic Solenoid Function - Wood
... The solenoid is used to supply voltage to the positive contact block only when the key is on. This solenoid is 12 volt dc activated. This is a safety function that keeps the hydraulics from accidentally being operated while the key is off while the mill is being worked on. With the key on the small ...
... The solenoid is used to supply voltage to the positive contact block only when the key is on. This solenoid is 12 volt dc activated. This is a safety function that keeps the hydraulics from accidentally being operated while the key is off while the mill is being worked on. With the key on the small ...
Lecture 7: High-level power reduction and management
... Duplicate part of logic to precompute circuit output values one cycle before they are required Use these values to reduce the total amount of switching in the circuit in the next cycle ...
... Duplicate part of logic to precompute circuit output values one cycle before they are required Use these values to reduce the total amount of switching in the circuit in the next cycle ...
Conquering the Multi Kilowatt Source/Sink Test
... A BSS is predominantly a voltage device; both the DC source and the electronic load normally operate in constant voltage (CV) mode. Their voltage is offset to provide a deadband so that they do not overlap in operation, with the electronic load’s voltage being set slightly greater than that of the D ...
... A BSS is predominantly a voltage device; both the DC source and the electronic load normally operate in constant voltage (CV) mode. Their voltage is offset to provide a deadband so that they do not overlap in operation, with the electronic load’s voltage being set slightly greater than that of the D ...
AD7899 5 V Single Supply 14-Bit 400 kSPS ADC
... Chip Select Input. Active low logic input. The device is selected when this input is active. Convert Start Input. Logic Input. A low to high transition on this input puts the track/hold into hold mode and starts conversion. Conversion Clock Input. CLKIN is an externally applied clock which allows th ...
... Chip Select Input. Active low logic input. The device is selected when this input is active. Convert Start Input. Logic Input. A low to high transition on this input puts the track/hold into hold mode and starts conversion. Conversion Clock Input. CLKIN is an externally applied clock which allows th ...
Time Delay Relays – Application Data
... Time delay relays are simply control relays with a time delay built in. Their purpose is to control an event based on time. The difference between relays and time delay relays is when the output contacts open & close: on a control relay, it happens when voltage is applied and removed from the coil; ...
... Time delay relays are simply control relays with a time delay built in. Their purpose is to control an event based on time. The difference between relays and time delay relays is when the output contacts open & close: on a control relay, it happens when voltage is applied and removed from the coil; ...
HMC727LC3C 数据资料DataSheet下载
... The HMC727LC3C is a D-Type Flip-Flop designed to support data transmission rates of up to 14 Gbps, and clock frequencies as high as 14 GHz. During normal operation, data is transferred to the outputs on the positive edge of the clock. Reversing the clock inputs allows for negative-edge triggered app ...
... The HMC727LC3C is a D-Type Flip-Flop designed to support data transmission rates of up to 14 Gbps, and clock frequencies as high as 14 GHz. During normal operation, data is transferred to the outputs on the positive edge of the clock. Reversing the clock inputs allows for negative-edge triggered app ...
Power Supply Noise Reduction - The Designer`s Guide Community
... values lie between 1 μH and 2 μH for a linear three terminal regulator. The output impedance of switching regulators varies widely and should be measured for each case. The interconnecting leads add about 20 nH per inch. When an active load is connected, the time varying current demand creates a noi ...
... values lie between 1 μH and 2 μH for a linear three terminal regulator. The output impedance of switching regulators varies widely and should be measured for each case. The interconnecting leads add about 20 nH per inch. When an active load is connected, the time varying current demand creates a noi ...
Thermistor/Relay Lab
... flow from C to E. Likewise, no current at B, to current through E! This will reverse the effect of our last circuit, where a +V signal from the op-amp shut things down (turned off LED). Here it will allow things to get current (operate relay). The arrow in the transistor pictogram does indeed repres ...
... flow from C to E. Likewise, no current at B, to current through E! This will reverse the effect of our last circuit, where a +V signal from the op-amp shut things down (turned off LED). Here it will allow things to get current (operate relay). The arrow in the transistor pictogram does indeed repres ...
Document
... The current through the meter movement is 16.6 μA in situation . This means the meter face is marked as 20Ω at 33.2% of full-scale deflection. When the ohmmeter is on the R x 1 range, a reading of 20Ω times multiplier of 10 means the unknown resistor has a value of 20 Ω. When ohmmeter is on the R x ...
... The current through the meter movement is 16.6 μA in situation . This means the meter face is marked as 20Ω at 33.2% of full-scale deflection. When the ohmmeter is on the R x 1 range, a reading of 20Ω times multiplier of 10 means the unknown resistor has a value of 20 Ω. When ohmmeter is on the R x ...
UVR 16x2 - Technische Alternative
... Technical data UVR16x2 (Relay versions) ......................................................................... 70 Technical data UVR16x2…-D (Triac versions) ................................................................... 71 ...
... Technical data UVR16x2 (Relay versions) ......................................................................... 70 Technical data UVR16x2…-D (Triac versions) ................................................................... 71 ...
QUADRUPLE OPERATIONAL AMPLIFIER LM2902-EP FEATURES
... designed specifically to operate from a single supply over a wide range of voltages. Operation from split supplies is possible when the difference between the two supplies is 3 V to 26 V (3 V to 32 V for V-suffixed devices) and VCC is at least 1.5 V more positive than the input common-mode voltage. ...
... designed specifically to operate from a single supply over a wide range of voltages. Operation from split supplies is possible when the difference between the two supplies is 3 V to 26 V (3 V to 32 V for V-suffixed devices) and VCC is at least 1.5 V more positive than the input common-mode voltage. ...
ADM2582E 数据手册DataSheet 下载
... The ADM2582E/ADM2587E driver has an active high enable. An active low receiver enable is also provided that causes the receiver output to enter a high impedance state when disabled. The devices have current limiting and thermal shutdown features to protect against output short circuits and situation ...
... The ADM2582E/ADM2587E driver has an active high enable. An active low receiver enable is also provided that causes the receiver output to enter a high impedance state when disabled. The devices have current limiting and thermal shutdown features to protect against output short circuits and situation ...
MAX8600/MAX8601 Single-/Dual-Input 1-Cell Li+ Chargers with OVP Protection and Programmable Charge Timer
... The MAX8600/MAX8601 single-/dual-input linear battery chargers safely charge single-cell Li+ batteries. The charging rate is optimized to accommodate the thermal characteristics of a given application. There is no need to reduce the maximum charge current or worst-case charger power dissipation. Cha ...
... The MAX8600/MAX8601 single-/dual-input linear battery chargers safely charge single-cell Li+ batteries. The charging rate is optimized to accommodate the thermal characteristics of a given application. There is no need to reduce the maximum charge current or worst-case charger power dissipation. Cha ...
56F8300 Digital Power Factor Correction using Processor Expert
... incidental damages. “Typical” parameters that may be provided in Freescale Semiconductor data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals”, must be validated for each customer applicat ...
... incidental damages. “Typical” parameters that may be provided in Freescale Semiconductor data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals”, must be validated for each customer applicat ...
Assemble Manual - DIY, audio, electronics
... 4. Solder the rest of the resistors in place. See table 1 for selecting the input resistor values. 5. Solder C14, C15, C100 and C20 in place. As with all electrolytic capacitor the polarity must be respected. The positive pad is usually rectangular and marked with a “+” on the PCB, while the negativ ...
... 4. Solder the rest of the resistors in place. See table 1 for selecting the input resistor values. 5. Solder C14, C15, C100 and C20 in place. As with all electrolytic capacitor the polarity must be respected. The positive pad is usually rectangular and marked with a “+” on the PCB, while the negativ ...
MAX5407 32-Tap Audio Logarithmic Taper Digital Potentiometer General Description
... When the ZCEN input is low, the zero-crossing detect feature is enabled. This feature reduces the audible noise (“clicks and pops”) that result from wiper transitions. When zero-crossing detection is enabled, the wiper changes position only when the voltage at L is the same as the voltage at H. If n ...
... When the ZCEN input is low, the zero-crossing detect feature is enabled. This feature reduces the audible noise (“clicks and pops”) that result from wiper transitions. When zero-crossing detection is enabled, the wiper changes position only when the voltage at L is the same as the voltage at H. If n ...
Data Sheet 85001-0640 - Edwards | Fire Alarm Systems, Life Safety
... Programming and Field Configuration Each AB4G base uses the same address and programming label as the detector it supports. AB4G sounder bases can be set to simply operate according to the state of its detector, or configured through system programming to operate in conjunction with all sounder base ...
... Programming and Field Configuration Each AB4G base uses the same address and programming label as the detector it supports. AB4G sounder bases can be set to simply operate according to the state of its detector, or configured through system programming to operate in conjunction with all sounder base ...