
SmartFusion cSoC: DC Fan Control Using PWM
... 1. ON/OFF control: The simplest method is ON/OFF control. The fan can be switched ON using a drive signal when the temperature of the particular component exceeds the threshold or it can be switched OFF when the temperature is under the threshold level. Even though the method is very simple, the dis ...
... 1. ON/OFF control: The simplest method is ON/OFF control. The fan can be switched ON using a drive signal when the temperature of the particular component exceeds the threshold or it can be switched OFF when the temperature is under the threshold level. Even though the method is very simple, the dis ...
generator - Marathon Electric
... indoors in a clean, dry area which is not subject to rapid changes in temperature and humidity. If the generator is stored for a long period of time, the generator should be tested, cleaned and dried as required before being put into service. See the maintenance section of this manual for further in ...
... indoors in a clean, dry area which is not subject to rapid changes in temperature and humidity. If the generator is stored for a long period of time, the generator should be tested, cleaned and dried as required before being put into service. See the maintenance section of this manual for further in ...
Application guide No. 3193
... Today’s world is full of electronic products and electrical devices that are susceptible to damage from overvoltage surges. Surges caused by static discharge, capacitive and inductive loads or lightning can quickly destroy sophisticated electronic equipment and components used in industrial and comm ...
... Today’s world is full of electronic products and electrical devices that are susceptible to damage from overvoltage surges. Surges caused by static discharge, capacitive and inductive loads or lightning can quickly destroy sophisticated electronic equipment and components used in industrial and comm ...
jerome 431-x - Arizona Instrument LLC
... When regeneration is complete, zero the sensor by pressing the ZERO button and turning the zero adjust screw, located under the handle, until the display reads 0. The instrument is now ready to sample. To ensure the input to the instrument contains no Mercury Vapor or mercaptans, use a Zero Ai ...
... When regeneration is complete, zero the sensor by pressing the ZERO button and turning the zero adjust screw, located under the handle, until the display reads 0. The instrument is now ready to sample. To ensure the input to the instrument contains no Mercury Vapor or mercaptans, use a Zero Ai ...
Control of Multi-terminal VSC-HVDC Systems
... offshore sites. These gas turbines have much less efficiency than onshore generation of electricity and also release large amounts of green house gases. Therefore supplying the platforms with power from onshore transmitted by HVDC will result in benefits both from economic and environmental protecti ...
... offshore sites. These gas turbines have much less efficiency than onshore generation of electricity and also release large amounts of green house gases. Therefore supplying the platforms with power from onshore transmitted by HVDC will result in benefits both from economic and environmental protecti ...
Fluorescent Lamp Starters
... This ability of the starter to shut down lamps that are faulty or are at the end of their lives enhances the SAFETY, convenience and life of a lighting system. ...
... This ability of the starter to shut down lamps that are faulty or are at the end of their lives enhances the SAFETY, convenience and life of a lighting system. ...
Coordinating Dissimilar Line Relays in a Communications
... signal to the remote strong terminal, preventing operation for an external fault. For an external fault behind the strong terminal, the weak terminal will likely not even see the fault and, therefore, will rarely operate for an external fault. If the terminal is considered weak because there is no s ...
... signal to the remote strong terminal, preventing operation for an external fault. For an external fault behind the strong terminal, the weak terminal will likely not even see the fault and, therefore, will rarely operate for an external fault. If the terminal is considered weak because there is no s ...
DNV-RP-D102: Failure Mode and Effect Analysis (FMEA) of
... A typical benign failure mode is loss of power output, whereas overvoltage will be considered as a non-benign failure mode. There is a need to define which possible states a system may enter into after a failure. It cannot be assumed that a system or component is simply lost (absence of function). T ...
... A typical benign failure mode is loss of power output, whereas overvoltage will be considered as a non-benign failure mode. There is a need to define which possible states a system may enter into after a failure. It cannot be assumed that a system or component is simply lost (absence of function). T ...
Mixed Swing Techniques for Low Energy/Operation Datapath Circuits
... approaches are investigated to demonstrate the ability to voltage-scale more aggressively than static CMOS well into the deep-submicron regime. Posynomial formulations for power and delay based on submicron MOS models are derived for mixed swing circuits to study and exploit the additional degrees o ...
... approaches are investigated to demonstrate the ability to voltage-scale more aggressively than static CMOS well into the deep-submicron regime. Posynomial formulations for power and delay based on submicron MOS models are derived for mixed swing circuits to study and exploit the additional degrees o ...
CEAG Central Battery System ZB-S
... LONWorks® - technology can communicate with the systems via the CG-S – bus. Alternative each Building Management System which is OPC compatible can be connected to the CGS – bus via an optional available OPC – Server and interface-box. So the CG-S – Bus has the possibility to call off voluminous sta ...
... LONWorks® - technology can communicate with the systems via the CG-S – bus. Alternative each Building Management System which is OPC compatible can be connected to the CGS – bus via an optional available OPC – Server and interface-box. So the CG-S – Bus has the possibility to call off voluminous sta ...
LTM8027 - 60V, 4A DC/DC uModule Regulator
... RT (Pin B1): The RT pin is used to program the switching frequency of the LTM8027 by connecting a resistor from this pin to ground. The Applications Information section of the data sheet includes a table to determine the resistance value based on the desired switching frequency. Minimize capacitance ...
... RT (Pin B1): The RT pin is used to program the switching frequency of the LTM8027 by connecting a resistor from this pin to ground. The Applications Information section of the data sheet includes a table to determine the resistance value based on the desired switching frequency. Minimize capacitance ...
Simple Renard RGB+W Controller
... The Simple Renard RGB+W uses a similar architecture for the logic portions of the board as the other Renard boards. Sequence information is passed from a PC running Vixen or other sequencing program via an RS-485 interface. The RS485 chip receives this information and turn into standard TTL logic le ...
... The Simple Renard RGB+W uses a similar architecture for the logic portions of the board as the other Renard boards. Sequence information is passed from a PC running Vixen or other sequencing program via an RS-485 interface. The RS485 chip receives this information and turn into standard TTL logic le ...
PV Inverter SUNNY BOY 6000TL‑US ⁄ 7000TL‑US
... its distributors or dealers nor SMA Solar Technology Canada Inc. nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances. (The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exc ...
... its distributors or dealers nor SMA Solar Technology Canada Inc. nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances. (The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exc ...
instruction manual
... Low Set and High Set potentiometers are adjusted to set low and high reference voltages to U110 and U111, which change states when the tension input signal falls below or rise above these preset reference voltages ...
... Low Set and High Set potentiometers are adjusted to set low and high reference voltages to U110 and U111, which change states when the tension input signal falls below or rise above these preset reference voltages ...
MAX 10 Schematic Review Worksheet
... Within each focus area, there is a table that contains the voltage or pin name for all of the dedicated and dual purpose pins for the device family. In some cases, the device density and package combination may not include some of the pins shown in this worksheet, you should cross reference with the ...
... Within each focus area, there is a table that contains the voltage or pin name for all of the dedicated and dual purpose pins for the device family. In some cases, the device density and package combination may not include some of the pins shown in this worksheet, you should cross reference with the ...
Integra Digital Metering System
... of this innovative product is easily enhanced to meet new client expectations. Integra plugin option modules allow cost effective upgrades with any combination of pulsed and digital communication outputs. The option module is interchangeable without recalibration. ...
... of this innovative product is easily enhanced to meet new client expectations. Integra plugin option modules allow cost effective upgrades with any combination of pulsed and digital communication outputs. The option module is interchangeable without recalibration. ...
3 - Schneider Electric Belgique
... CAUTION indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. ...
... CAUTION indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. ...
DEEP SEA ELECTRONICS DSE8600 Series PC configuration suite
... All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder except in accordance with the provisions of the Copyright, Designs and Patents ...
... All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder except in accordance with the provisions of the Copyright, Designs and Patents ...
supervisión de la temperatura en los bobinados y estator en un
... Tabla 18. Tabla total costos fijos..............................................................................................................41 Tabla 19. Tabla de los costos de procura..................................................................................................41 Tabla 20. Ta ...
... Tabla 18. Tabla total costos fijos..............................................................................................................41 Tabla 19. Tabla de los costos de procura..................................................................................................41 Tabla 20. Ta ...