Designing of a variable frequency standalone impedance analyzer
... Current mirror is used to maintain equal current flow in two different branches regardless of loading. This type of current source is more advantageous because of its high input impedance. For generation of constant current we need a current generator, current mirror and a current regulator. This ty ...
... Current mirror is used to maintain equal current flow in two different branches regardless of loading. This type of current source is more advantageous because of its high input impedance. For generation of constant current we need a current generator, current mirror and a current regulator. This ty ...
MAX44264 Ultra-Low Power Op Amp in a Tiny 6
... The common-mode input range of the MAX44264 extends down to ground, and offers excellent commonmode rejection. These devices are guarante ed not to undergo phase reversal when the input is overdriven. Power Supplies and Layout applications, good layout is extremely important because low-power requir ...
... The common-mode input range of the MAX44264 extends down to ground, and offers excellent commonmode rejection. These devices are guarante ed not to undergo phase reversal when the input is overdriven. Power Supplies and Layout applications, good layout is extremely important because low-power requir ...
electronic-vu-meter. - uk
... There are two types of meter specifically designed for audio use. A VU (Volume Unit) meter, commonly found on domestic audio recorders, displays the average volume level of an audio signal. A PPM (Peak Program Meter), used in professional audio equipment, displays the peak volume level of an audio s ...
... There are two types of meter specifically designed for audio use. A VU (Volume Unit) meter, commonly found on domestic audio recorders, displays the average volume level of an audio signal. A PPM (Peak Program Meter), used in professional audio equipment, displays the peak volume level of an audio s ...
1 - Brown University
... Load (amps, KW and KVA), voltage, and transfer switch position (load connected to normal, load connected to Emergency), 5. Monitor the generator run status and alarm status panel alarm points. 6. Meter monitoring shall be via MODBUS (RS 485) connection to each transfer switch and generator. B. Build ...
... Load (amps, KW and KVA), voltage, and transfer switch position (load connected to normal, load connected to Emergency), 5. Monitor the generator run status and alarm status panel alarm points. 6. Meter monitoring shall be via MODBUS (RS 485) connection to each transfer switch and generator. B. Build ...
Blancett K-Factor Scaler Elbow Style Frequency Divider
... counting and display. The use of different K-Factor values allows the device to display in any number of volumetric measurements such as gallons, cubic meters, liters, barrels and like units. The calibration sheet usually provided with a turbine meter lists a nominal K-Factor tested to a specific vo ...
... counting and display. The use of different K-Factor values allows the device to display in any number of volumetric measurements such as gallons, cubic meters, liters, barrels and like units. The calibration sheet usually provided with a turbine meter lists a nominal K-Factor tested to a specific vo ...
Additional safety prescriptions for trolleybuses
... voltage (UTest) shall be at least 1,500 V, with U the highest occurring voltage: Basic Insulation: UTest = 2 x U + 1,000 V The equivalent DC test voltage is √2 times the AC value. Components that have already been tested at their time of manufacture shall be excluded. The factory tests may be perfor ...
... voltage (UTest) shall be at least 1,500 V, with U the highest occurring voltage: Basic Insulation: UTest = 2 x U + 1,000 V The equivalent DC test voltage is √2 times the AC value. Components that have already been tested at their time of manufacture shall be excluded. The factory tests may be perfor ...
TPS6211x 17-V, 1.5-A, Synchronous Step
... Power good comparator output. This is an open-drain output. A pullup resistor should be connected between PG and VOUT. The output goes high when the output voltage is greater than 98.4% of the nominal value. If not used, the pin may be left floating or connected to GND. ...
... Power good comparator output. This is an open-drain output. A pullup resistor should be connected between PG and VOUT. The output goes high when the output voltage is greater than 98.4% of the nominal value. If not used, the pin may be left floating or connected to GND. ...
Concepts Addressed in Lesson - Union
... Unit 7: Flip-Flops Lesson 7.1 Introduction to Sequential Logic Concepts Addressed in Lesson 1. Latches are devices which have the capability to store data and can act as memory devices. Latches store data when the clock is low; a flip flop stores data when the clock rises. Sequential circuits store ...
... Unit 7: Flip-Flops Lesson 7.1 Introduction to Sequential Logic Concepts Addressed in Lesson 1. Latches are devices which have the capability to store data and can act as memory devices. Latches store data when the clock is low; a flip flop stores data when the clock rises. Sequential circuits store ...
ADP5090 (Rev. A)
... storage elements management controller. It converts power from low voltage, high impedance dc sources such as PV cells, TEGs, and piezoelectric modules. The device stores power in the rechargeable battery or capacitor with storage protection, and provides power to the load. It can also control an ad ...
... storage elements management controller. It converts power from low voltage, high impedance dc sources such as PV cells, TEGs, and piezoelectric modules. The device stores power in the rechargeable battery or capacitor with storage protection, and provides power to the load. It can also control an ad ...
Level Conversion for Dual-Supply Systems
... in the circuit begins to disappear [1]. Lowering supply voltage results in a quadratic reduction in power dissipation but it significantly impacts delay. In constant-throughput applications, the performance loss due to low supply operation is recovered by increased pipelining or parallelism [2], but ...
... in the circuit begins to disappear [1]. Lowering supply voltage results in a quadratic reduction in power dissipation but it significantly impacts delay. In constant-throughput applications, the performance loss due to low supply operation is recovered by increased pipelining or parallelism [2], but ...
Multimeter
... continuity. Replace damaged test leads with identical model number or electrical specifications before using the Meter. Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and grounding. The rotary switch should be placed in the right posit ...
... continuity. Replace damaged test leads with identical model number or electrical specifications before using the Meter. Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and grounding. The rotary switch should be placed in the right posit ...
DC Biasing using a S..
... There are two resistors left Q: OK, we now have enough information to set IC ,VC , and VE , and thus resistors RC and RE . But we still have two bias resistors left— R1 and R2 . How do we determine their ...
... There are two resistors left Q: OK, we now have enough information to set IC ,VC , and VE , and thus resistors RC and RE . But we still have two bias resistors left— R1 and R2 . How do we determine their ...
stator core faults detection with low flux density method
... deep in the core may occur as a result of the ageing effects causing sheet shortcircuiting. At the same time, mechanical accidents (impacts, frictions) that may cause short-circuit in the part towards the air gap of the sheets may occur. These minor internal or surface faults can lead to a significa ...
... deep in the core may occur as a result of the ageing effects causing sheet shortcircuiting. At the same time, mechanical accidents (impacts, frictions) that may cause short-circuit in the part towards the air gap of the sheets may occur. These minor internal or surface faults can lead to a significa ...
Review of Voltage Sag Compensation Techniques
... Fig. 4 Ultra-reliable power is supplied cost-effectively by using a vacuum transfer switch plus a voltage sag corrector with ride-through capability D. Interphase AC-AC topology To compensate the voltage sag, a new interphase ac-ac topology has been developed. The proposed topology does not need a s ...
... Fig. 4 Ultra-reliable power is supplied cost-effectively by using a vacuum transfer switch plus a voltage sag corrector with ride-through capability D. Interphase AC-AC topology To compensate the voltage sag, a new interphase ac-ac topology has been developed. The proposed topology does not need a s ...
LT6105 Precision, Extended Input Range Current Sense Amplifi er FEATURES
... Gain is configured with external resistors from 1V/V to 100V/V. The input common mode rejection and power supply rejection are in excess of 100dB and the input offset voltage is less than 300μV. A typical slew rate of 2V/μs ensures fast response to unexpected current changes. The LT6105 can operate f ...
... Gain is configured with external resistors from 1V/V to 100V/V. The input common mode rejection and power supply rejection are in excess of 100dB and the input offset voltage is less than 300μV. A typical slew rate of 2V/μs ensures fast response to unexpected current changes. The LT6105 can operate f ...
NX3L2267 1. General description Low-ohmic dual single-pole double-throw analog switch
... The NX3L2267 is a dual low-ohmic single-pole double-throw analog switch suitable for use as an analog or digital 2:1 multiplexer/demultiplexer. Each switch has a digital select input (nS), two independent inputs/outputs (nY0 and nY1) and a common input/output (nZ). Schmitt trigger action at the digi ...
... The NX3L2267 is a dual low-ohmic single-pole double-throw analog switch suitable for use as an analog or digital 2:1 multiplexer/demultiplexer. Each switch has a digital select input (nS), two independent inputs/outputs (nY0 and nY1) and a common input/output (nZ). Schmitt trigger action at the digi ...
Datasheet
... • SerDes optionally turned-off in D3hot • SerDes associated with unused ports are turned-off • SerDes associated with unused lanes are placed in a low power state ...
... • SerDes optionally turned-off in D3hot • SerDes associated with unused ports are turned-off • SerDes associated with unused lanes are placed in a low power state ...
TLC2554 数据资料 dataSheet 下载
... In addition to a high-speed A/D converter and versatile control capability, these devices have an on-chip analog multiplexer that can select any analog inputs or one of three internal self-test voltages. The sample-and-hold function is automatically started after the fourth SCLK edge (normal samplin ...
... In addition to a high-speed A/D converter and versatile control capability, these devices have an on-chip analog multiplexer that can select any analog inputs or one of three internal self-test voltages. The sample-and-hold function is automatically started after the fourth SCLK edge (normal samplin ...