MAX9312/MAX9314 Dual 1:5 Differential LVPECL/LVECL/HSTL Clock and Data Drivers General Description
... The MAX9312/MAX9314 are low-skew, dual 1-to-5 differential drivers designed for clock and data distribution. For interfacing to differential HSTL and LVPECL signals, these devices operate over a +2.25V to +3.8V supply range, allowing high-performance clock or data distribution in systems with a nomi ...
... The MAX9312/MAX9314 are low-skew, dual 1-to-5 differential drivers designed for clock and data distribution. For interfacing to differential HSTL and LVPECL signals, these devices operate over a +2.25V to +3.8V supply range, allowing high-performance clock or data distribution in systems with a nomi ...
+5.0V, ±15kV ESD-Protected, Fail-Safe, Hot-Swap, RS-485/RS-422 Transceivers General Description Features
... The MAX13080E–MAX13089E +5.0V, ±15kV ESD-protected, RS-485/RS-422 transceivers feature one driver and one receiver. These devices include fail-safe circuitry, guaranteeing a logic-high receiver output when receiver inputs are open or shorted. The receiver outputs a logichigh if all transmitters on a ...
... The MAX13080E–MAX13089E +5.0V, ±15kV ESD-protected, RS-485/RS-422 transceivers feature one driver and one receiver. These devices include fail-safe circuitry, guaranteeing a logic-high receiver output when receiver inputs are open or shorted. The receiver outputs a logichigh if all transmitters on a ...
MAX4370 Current-Regulating Hot-Swap Controller with DualSpeed/BiLevel Fault Protection General Description
... pump as gate drive for an external N-channel MOSFET, an external current-sense resistor, and two on-chip comparators. Figure 1 shows the device’s functional diagram. The slow comparator response time and the start-up timer can be adjusted with external capacitors. The timing components are optional; ...
... pump as gate drive for an external N-channel MOSFET, an external current-sense resistor, and two on-chip comparators. Figure 1 shows the device’s functional diagram. The slow comparator response time and the start-up timer can be adjusted with external capacitors. The timing components are optional; ...
REG670 Generator Protection Relay – Commissioning Guide Anders Hermans
... Safety requirements for personnel and material are the two primary elements that have an impact on the magnitude and the establishment of a protective relay. The secondary elements are technical and economical aspects. The following elements have more or less impact on the establishment of a protect ...
... Safety requirements for personnel and material are the two primary elements that have an impact on the magnitude and the establishment of a protective relay. The secondary elements are technical and economical aspects. The following elements have more or less impact on the establishment of a protect ...
LTM8061 - 32V, 2A uModule Li-Ion/ Polymer Battery Charger
... the internal timer is used for termination, the pin stays low during the charge cycle until the charge current drops below a C/10 rate even though the charger will continue to top off the battery until the end-of-charge timer terminates the charge cycle. A temperature fault also causes this pin to b ...
... the internal timer is used for termination, the pin stays low during the charge cycle until the charge current drops below a C/10 rate even though the charger will continue to top off the battery until the end-of-charge timer terminates the charge cycle. A temperature fault also causes this pin to b ...
RMS6091EF74FAW-1600
... In addition to the column address, AP is used to invoke autoprecharge operation at the end of the burst read or write cycle. If AP is high, autoprecharge is selected and BA0, BA1, BA2 defines the bank to be precharged. If AP is low, auto-precharge is disabled. During a Precharge command cycle, AP is ...
... In addition to the column address, AP is used to invoke autoprecharge operation at the end of the burst read or write cycle. If AP is high, autoprecharge is selected and BA0, BA1, BA2 defines the bank to be precharged. If AP is low, auto-precharge is disabled. During a Precharge command cycle, AP is ...
Nexto Series User Manual Doc. Cod.: MU214600
... modules for motion control, communication and interface to the most popular field networks among other features. Nexto Series uses an advanced technology in its bus, which is based on a high speed Ethernet, allowing input and output information and data to be shared between all modules of the system ...
... modules for motion control, communication and interface to the most popular field networks among other features. Nexto Series uses an advanced technology in its bus, which is based on a high speed Ethernet, allowing input and output information and data to be shared between all modules of the system ...
W5A-580 Transmission Control Sys 1998
... selected gear until the ignition is switched OFF. When the vehicle is restarted (after a minimum 10 second wait), the transmission will operate in 2nd and REVERSE only. The default will remain in effect until the fault is corrected and the DTC erased from memory. Mechanical limp home occurs when a m ...
... selected gear until the ignition is switched OFF. When the vehicle is restarted (after a minimum 10 second wait), the transmission will operate in 2nd and REVERSE only. The default will remain in effect until the fault is corrected and the DTC erased from memory. Mechanical limp home occurs when a m ...
Sample 243-133-VA Electrical Technology Assessments
... Students are tested on their understanding of the use of the technical vocabulary (not on definitions) on the tests. They are expected to recognise how the terms should be used. All assessments. ...
... Students are tested on their understanding of the use of the technical vocabulary (not on definitions) on the tests. They are expected to recognise how the terms should be used. All assessments. ...
Low-Power Digital Signal Processing Using
... this freedom to come up with low-power designs at different levels of design abstraction, namely, logic, architecture, and algorithm. The paradigm of approximate computing is specific to select hardware implementations of DSP blocks. It is shown in [1] that an embedded reduced instruction set comput ...
... this freedom to come up with low-power designs at different levels of design abstraction, namely, logic, architecture, and algorithm. The paradigm of approximate computing is specific to select hardware implementations of DSP blocks. It is shown in [1] that an embedded reduced instruction set comput ...
azur 640T V2.0 - Cambridge Audio
... fitted with a 3 amp fuse inside. If it is necessary to change the fuse, it is important that a 3 amp one is used. If the plug needs to be changed because it is not suitable for your socket, or becomes damaged, it should be cut off and an appropriate plug fitted following the wiring instructions belo ...
... fitted with a 3 amp fuse inside. If it is necessary to change the fuse, it is important that a 3 amp one is used. If the plug needs to be changed because it is not suitable for your socket, or becomes damaged, it should be cut off and an appropriate plug fitted following the wiring instructions belo ...
ADP1823 数据手册DataSheet 下载
... Error Amplifier Output for Channel 2. Connect an RC network from COMP2 to FB2 to compensate Channel 2. Tracking Input for Channel 2. To track a master voltage, drive TRK2 from a voltage divider to the master voltage. If the tracking function is not used, connect TRK2 to VREG. Soft Start Control Inpu ...
... Error Amplifier Output for Channel 2. Connect an RC network from COMP2 to FB2 to compensate Channel 2. Tracking Input for Channel 2. To track a master voltage, drive TRK2 from a voltage divider to the master voltage. If the tracking function is not used, connect TRK2 to VREG. Soft Start Control Inpu ...
TPS60500 数据资料 dataSheet 下载
... The TPS6050x charge pumps provide a regulated output voltage in the range of 0.8 V to 3.3 V from an input voltage of 1.8 V to 6.5 V. The devices use switched capacitor fractional conversion to achieve high efficiency over the entire input and output voltage range. Regulation is achieved by sensing t ...
... The TPS6050x charge pumps provide a regulated output voltage in the range of 0.8 V to 3.3 V from an input voltage of 1.8 V to 6.5 V. The devices use switched capacitor fractional conversion to achieve high efficiency over the entire input and output voltage range. Regulation is achieved by sensing t ...
LTC6101/LTC6101HV - High Voltage, High
... provides accurate monitoring of current through a userselected sense resistor. The sense voltage is amplified by a user-selected gain and level shifted from the positive power supply to a ground-referred output. The output signal is analog and may be used as is or processed with an output filter. Theo ...
... provides accurate monitoring of current through a userselected sense resistor. The sense voltage is amplified by a user-selected gain and level shifted from the positive power supply to a ground-referred output. The output signal is analog and may be used as is or processed with an output filter. Theo ...
clickPAN-SERVO - Gentles Limited
... Make sure all connections are made as per the instructions. For servo issues, make sure the shutter servo is an unmodified one and the pan servo has been modified for 360º operation. Make sure the modified pan servo is connected to the 6-pin end of the device, and the unmodified standard servo to th ...
... Make sure all connections are made as per the instructions. For servo issues, make sure the shutter servo is an unmodified one and the pan servo has been modified for 360º operation. Make sure the modified pan servo is connected to the 6-pin end of the device, and the unmodified standard servo to th ...
ADF4360-5 VCO-PLL - University of Toronto Physics
... 24-bit shift register on the CLK rising edge. This input is a high impedance CMOS input. Serial Data Input. The serial data is loaded MSB first with the two LSBs being the control bits. This input is a high impedance CMOS input. Load Enable, CMOS Input. When LE goes high, the data stored in the shif ...
... 24-bit shift register on the CLK rising edge. This input is a high impedance CMOS input. Serial Data Input. The serial data is loaded MSB first with the two LSBs being the control bits. This input is a high impedance CMOS input. Load Enable, CMOS Input. When LE goes high, the data stored in the shif ...
Course Syllabus
... LATE POLICY: Unexcused late material will be accepted up to a week after it was due, and will be graded at 75% off. If you miss a lab, it may be made up only because of medical reasons, or family emergency. The lab should be made up by noon on the Monday following the lab session that you missed. Ma ...
... LATE POLICY: Unexcused late material will be accepted up to a week after it was due, and will be graded at 75% off. If you miss a lab, it may be made up only because of medical reasons, or family emergency. The lab should be made up by noon on the Monday following the lab session that you missed. Ma ...
SLIC Devices
... These functions are useful for the prediction of system return loss and echo cancellation performance. The value of K1 can be found in each device’s data sheet referred to as the current gain. GTX in dB is specified in each data sheet under two- to four-wire gain accuracy. CHP sets the low frequency ...
... These functions are useful for the prediction of system return loss and echo cancellation performance. The value of K1 can be found in each device’s data sheet referred to as the current gain. GTX in dB is specified in each data sheet under two- to four-wire gain accuracy. CHP sets the low frequency ...
Ground Fault Protection for an Ungrounded System
... The purpose of this report is to demonstrate the knowledge of key concepts presented in EE5223 Electrical Power System Protection. This project includes the development of a ground fault protection scheme for an ungrounded system, starting from the basic concepts presented in the course textbook and ...
... The purpose of this report is to demonstrate the knowledge of key concepts presented in EE5223 Electrical Power System Protection. This project includes the development of a ground fault protection scheme for an ungrounded system, starting from the basic concepts presented in the course textbook and ...