• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Chapter 1: Electricity
Chapter 1: Electricity

... Conventional Current  Motion of positive charges  Opposite the flow of electrons  Used in physics and electrical engineering in circuit analysis ...
MV-7 Current Transformer
MV-7 Current Transformer

... »» Transformers are shipped with the short- circuiting link closed and the terminal cover in the reversed (short-circuited) position. When a meter is installed, the terminal cover is removed, the meter current coils are connected across the transformers secondary terminals, the short-circuiting link ...
TTR 795 - Haefely Hipotronics
TTR 795 - Haefely Hipotronics

... the type 2767 automatic instrument transformer test set and the type 4860 electronic voltage divider, the system makes it possible to integrate burdens into a computer-controlled testing system. The electronic voltage burden replaces traditional burdens with passive resistances and inductances. The ...
TTR 25 Handheld TTR
TTR 25 Handheld TTR

university of california at berkeley - Berkeley Robotics and Intelligent
university of california at berkeley - Berkeley Robotics and Intelligent

... Now you will design the bandgap circuit shown above to generate VREF = 1.2V.  We will set R3 = R2.  Your op-amp may be a simple differential pair or a two stage opamp. It needs to run off of VBAT because at this point you don’t have any other voltages to work from.  The bipolar PNP transistors ar ...
Current Sense Circuit Collection
Current Sense Circuit Collection

TIP125/126/127 PNP Epitaxial Darlington Transistor
TIP125/126/127 PNP Epitaxial Darlington Transistor

... DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 2. A critical component is any component of a life support 1. Life support devices or systems are devices or systems device or system whose failure to perform can be which, (a) are intende ...
IXYS POWER
IXYS POWER

... Square RBSOA => allowing device to safely operate in a snubberless hard switching application Offered in co-packed versions, further improving switching capabilities ...
Benefits of Voltage Optimisation
Benefits of Voltage Optimisation

... 207V to 253V. However, above optimum voltage, any additional energy used will not necessarily improve performance. A device that has been designed to work anywhere in Europe, such as our electric fire, has an optimum operating point of 220V. Above this voltage and at the UK supply average of 242V, t ...
Spec Sheet - American Standard
Spec Sheet - American Standard

... UL-approved Hard-Wired AC transformer. MULTI-AC POWERED; dual inlets 7057205 with cast brass spout, 0.4 gpm (1.9 Lpm) pressure compensating, vandal-resistant nonaerated spray.  Above-Deck Mixing.  One power supply or transformer (sold separately) can operate up to 15 faucets and/or flush valves. 10' ...
Compact Power Line - Mouser Electronics
Compact Power Line - Mouser Electronics

... The CP1800AC52 Front-End Power Supplies in the Compact Power Line platform are specifically designed to operate as an integral part of a complete distributed power system. The high-density, front-toback airflow rectifier is designed for minimal space utilization and is highly expandable for future g ...
Document
Document

IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)

BP5037B12
BP5037B12

... Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no respo ...
The Rotating Magnetic Field Oscillator System for
The Rotating Magnetic Field Oscillator System for

is31lt3117 53v, 350ma, 4-channel constant current regulator
is31lt3117 53v, 350ma, 4-channel constant current regulator

... for guidance in calculating resistor values for specific currents. ...
Design and Simulation of Boost Converter for Power Factor
Design and Simulation of Boost Converter for Power Factor

... produced from the nonlinear loads, and a AC/DC converter lamps (arcing) and AC electric arc furnaces etc. supplies the DC power to its load and takes a nearly sinusoidal current from the supply. This approach reduces the cost of the filter, since no especially dedicated power devices are needed for ...
230/400 V 3-phase AC, secondary voltage: 24 V DC
230/400 V 3-phase AC, secondary voltage: 24 V DC

... Power Supply Unit 07 NG 36 R1 primary voltage: 230/400 V 3-phase AC, secondary voltage: 24 V DC, 20 A ...
high step-up converter with three-winding coupled
high step-up converter with three-winding coupled

... resistance (RDS-ON) and a snubber circuit are usually adopted in the fly back converter, but the leakage energy still be consumed. These methods will diminish the power conversion efficiency. In order to increase the conversion efficiency and voltage gain, many technologies such as zero-voltage swit ...
10-1 GLOSSARY TO TERMS A - Abbreviation for ampere. Absolute
10-1 GLOSSARY TO TERMS A - Abbreviation for ampere. Absolute

... Circular Mil - An area equal to that of a circle with a diameter of .001 inch. It is used for measuring the cross section of wires. Coil - An inductive device created by looping turns of wire around a core. Collector - The element in a transistor which collects the current carriers. Commutator - Th ...
download
download

... 48 VDC Control Voltage (Internal Source) The regulator control voltage is 48 VDC supplied by a built-in power supply. No separate power supply in the tower is required. Using individual power supplies for each regulator lessens the possibility of control system failure than when using a single centr ...
A Solution to Simplify 60A Multiphase Designs
A Solution to Simplify 60A Multiphase Designs

... improved the performance of discrete components significantly. For instance only 3-4 years ago it was state of the art to have a buck converter delivering about 7A to a microprocessor with a single high and low side MOSFET, but this level has now moved to around 15A. The layout of power components r ...
A 36-inch Surface-conduction Electron-emitter Display (SED)
A 36-inch Surface-conduction Electron-emitter Display (SED)

... consisting of cathode plate, anode plate and thin spacers, which allow the panel vacuum structure to be sustained under atmospheric pressure. Thin spacers are placed on the printed wires to avoid disturbing the electron paths. The cathode plate and anode plate are sealed by frit glass and a low melt ...
sb6100 industrial shock-block™ technical faq
sb6100 industrial shock-block™ technical faq

... 943C device or have the GFCI designation. With UL 943C and a clear definition of SPGFCIs, this is no longer acceptable. For any product to be used for personnel protection, it must be UL listed. The UL standard also has several additional safety features, such as: • Monitor ground wire to ensure re ...
AN-805 APPLICATION NOTE
AN-805 APPLICATION NOTE

< 1 ... 325 326 327 328 329 330 331 332 333 ... 449 >

Mercury-arc valve



A mercury-arc valve or mercury-vapor rectifier or (UK) mercury-arc rectifier is a type of electrical rectifier used for converting high-voltage or high-current alternating current (AC) into direct current (DC). It is a type of cold cathode gas-filled tube, but is unusual in that the cathode, instead of being solid, is made from a pool of liquid mercury and is therefore self-restoring. As a result, mercury-arc valves were much more rugged, long-lasting and could carry much higher currents than most other types of gas discharge tube.Invented in 1902 by Peter Cooper Hewitt, mercury-arc rectifiers were used to provide power for industrial motors, electric railways, streetcars, and electric locomotives, as well as for radio transmitters and for high-voltage direct current (HVDC) power transmission. They were the primary method of high power rectification before the advent of semiconductor rectifiers, such as diodes, thyristors and gate turn-off thyristors (GTOs) in the 1970s.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report